MITSUBISHI ELECTRIC PLA-A24EA8 24,000 BTU H 3’ X 3’ Ceiling Cassette Instruction Manual
- June 17, 2024
- Mitsubishi Electric
Table of Contents
- MITSUBISHI ELECTRIC PLA-A24EA8 24,000 BTU H 3’ X 3’ Ceiling Cassette
- Product Information
- Product Usage Instructions
- INDOOR UNIT FEATURES
- OUTDOOR UNIT FEATURES
- INDOOR UNIT ACCESSORIES
- OUTDOOR UNIT ACCESSORIES
- INDOOR UNIT DIMENSIONS
- OUTDOOR UNIT DIMENSIONS
- FAQ
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MITSUBISHI ELECTRIC PLA-A24EA8 24,000 BTU H 3’ X 3’ Ceiling Cassette
Product Information
Specifications
The product specifications for the PLA-A24EA8 & PUZ-A24NHA7 are as follows:
- Job Name: System Reference: PLA-A24EA8 & PUZ-A24NHA7
- 24,000 BTU/H 3′ X 3′ CEILING CASSETTE 24,000 BTU/H HEAT PUMP UNIVERSAL OUTDOOR
- Indoor Unit: PLA-A24EA8
- Outdoor Unit: PUZ-A24NHA7
- Electrical: 208/230, 1, 60 V AC
- Operating Temperature Range (Indoor Unit): 57°F to 89°F (DB), 40°F to 72°F (WB)
- Operating Temperature Range (Outdoor Unit): -8°F to 70°F (DB), -4°F to 59°F (WB)
- Dimensions (Indoor Unit): 33-1/16″ x 33-1/16″ x 11-3/4″ [840mm x 840mm x 298mm]
- Dimensions (Outdoor Unit): 37-13/32″ x 13 (+1-3/16)” x 37-1/8″ [950mm x 330mm (+30) x 943mm]
NOTES
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined at a fixed compressor speed) 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
Conditions 4
Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
- Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
- Wind baffles are required to operate below 23°F DB in cooling mode.
- Heat pump system with wind baffle: 0°F – 115°F.
- Refer to wind baffle documentation for further information.
Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
- The system cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
Blue Fin Coating Standard from 2022 production:
- PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U
- PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU
NOTES
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined at a fixed compressor speed) 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
Conditions 4
Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
- Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
- Wind baffles are required to operate below 23°F DB in cooling mode.
- Heat pump system with wind baffle: 0°F – 115°F.
- Refer to wind baffle documentation for further information.
Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
- The system cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
Blue Fin Coating Standard from 2022 production:
- PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U
- PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU
Product Usage Instructions
Installation
To install the PLA-A24EA8 & PUZ-A24NHA7, follow these steps:
- Choose a suitable location for the indoor unit on the ceiling. Ensure there is enough space for installation and maintenance.
- Install the outdoor unit in a well-ventilated area, away from direct sunlight and obstacles.
- Connect the refrigerant piping between the indoor and outdoor units, following the specified diameter and length requirements.
- Mount the indoor unit securely on the ceiling using the provided accessories.
- Make electrical connections according to the specified voltage and current requirements.
- Install any additional accessories, such as remote sensors or drain pans, if required.
- Test the system to ensure proper operation.
Operation
To operate the PLA-A24EA8 & PUZ-A24NHA7, use the following guidelines:
- Use the wired remote controller or centralized control interface to set the desired temperature and operating mode.
- Ensure that the air outlet guide is properly positioned for optimal air distribution.
- Maintain the centralized drain pan to prevent water leakage.
- Regularly clean and service the unit using the provided control/service tool.
- Use hail guards to protect the outdoor unit from damage.
- Install a wind baffle if needed to prevent wind interference.
INDOOR UNIT FEATURES
- Space-efficient ductless installation
- Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency
- Airflow settings for high and low ceiling applications
- Individual vane settings for direct/indirect airflow control or variable airflow patterns
- Knockouts for outside-air intake and branch-duct run
- Filter indicator signal
- Easy-to-clean, washable filter (optional high-efficiency filter available – requires multi-function casement)
- Built-in condensate lift mechanism
- Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more
- Multiple control options available:
- kumo cloud® smart device app for remote access
- Third-party interface options
- Wired or wireless controllers
OUTDOOR UNIT FEATURES
- Variable speed INVERTER-driven compressor
- Pre-charged with refrigerant volume for piping length up to 70 ft
- Low ambient cooling down to 0°F providing 100% capacity
- 24-hour continuous operation (cooling mode)
- High-pressure protection
- Fast restart
- Superior energy and operational efficiency
- Seacoast protection*
- External Outer Panel: Phosphate coating + Acrylic-Enamel coating
- Fan Motor Support: Epoxy resin coating (at edge face)
- Separator Assembly Valve Bed: Epoxy resin coating (at edge face)
- Blue Fin treatment is an anti-corrosion treatment that is applied to the Heat exchanger coil to protect it against airborne contaminants.
- Heat exchanger coil and base panel rated for 2,000 hours in accordance with ASTM B117 testing
- Seacoast protection standard from 2022 production.
INDOOR UNIT ACCESSORIES
OUTDOOR UNIT ACCESSORIES
INDOOR UNIT DIMENSIONS
OUTDOOR UNIT DIMENSIONS
1340 Satellite Boulevard Suwanee, GA 30024
Toll Free: 800-433-4822
www.mehvac.com
FAQ
Q: Can I use a wireless remote controller with the PLA-A24EA8?
A: No, the PAC-SF40RM-E wired remote controller is required for use with the PLA-A24EA8. Wireless remote controllers are not compatible.
Q: What are the operating temperature ranges for the indoor and outdoor units?
A: The indoor unit can operate within a temperature range of 57°F to 89°F (DB), 40°F to 72°F (WB). The outdoor unit can operate within a temperature range of -8°F to 70°F (DB), -4°F to 59°F (WB).
Q: What are the dimensions of the indoor and outdoor units?
A: The dimensions of the indoor unit are 33-1/16″ x 33-1/16″ x 11-3/4″ [840mm x 840mm x 298mm]. The dimensions of the outdoor unit are 37-13/32″ x 13 (+1-3/16)” x 37-1/8″ [950mm x 330mm (+30) x 943mm].
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>