PORTOR LIGHTING PT-RHB-3CP SERIES LED High Bay Light Installation Guide

June 17, 2024
PORTOR LIGHTING

PORTOR LIGHTING PT-RHB-3CP SERIES LED High Bay Light

Product Information

Specifications:

  • Product Series: PT-RHB-3CP
  • Models: PT-RHB-11D-3CP, PT-RHB-13D-3CP
  • Optional DC motion sensor
  • 0/1-10V dimming function

Product Usage Instructions

Installation

WARNING: RISK OF ELECTRIC SHOCK AND BURN. READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY.

WARNING: RISK OF INJURY AND FIRE.
Before starting the installation process, always turn off the power supply from the main circuit breaker first.

Wiring Diagram
This LED high bay light can be equipped with an optional DC motion sensor and is available with 0/1-10V dimming function. There are two dimming solutions:

  1. 0/1-10V dimming
  2. Intelligent dimming with DC motion sensor

To connect an outside dimmer, use the dimming+ and dimming- (DC 10V) marking leads. Ensure that the pink wire and black wire with shrinkable tubing are not damaged and have no connection. Only use Class 1 Wiring. Assure a cumulative leakage current of less than 3.5mA on the control circuit.

CCT/Wattage Adjustment
Easily flip the switch for the desired CCT (Correlated Color Temperature) and wattage before installation.

CCT Adjustment Switch
Adjust the CCT by using the provided switch.

Wattage Adjustment Switch
Adjust the wattage by using the provided switch.

Installation of DC Motion Sensor
If the fixture has a sensor receptacle installed, follow these steps:

  1. Screw the 1/2 Knockout out with a screwdriver in the illustrated direction
  2. Screw the sensor kit on

The sensor is set as universal mode (refer to sensor spec sheet), and the setting is programmable via remote control (remote control not included in standard packing).

Hook Mount Installation

  1. Screw the hook into the fixture and tighten it (Figure 1)
  2. Hang the fixture on the ceiling hook or chain (Figure 2)
  3. After installation, connect the wire of the fixture to the mains according to the local wiring rules. Ensure the connection is stable and well-protected.

Ceiling Mount Installation

  1. Mark with a mark pen or sharp tool on the mounting surface and drill (Figure 3)
  2. Fix screw into the hole with a hammer (Figure 4)
  3. Align the bracket hole with the screw hole and push the fixture to one side (Figure 5) and fix it (Figure 6)
  4. After installation, connect the wire of the fixture to the mains according to local wiring rules. Ensure the connection is stable and well-protected.

Pendant Mount Installation

  1. Unscrew the nuts on 1/2 NTP (Figure 8)
  2. Insert 1/2 NTP stem into the bracket hole (Figure 9)
  3. Re-screw the nuts (Figure 10)
  4. After installation, connect the wire of the fixture to the mains according to local wiring rules. Ensure the connection is stable and well-protected.

FAQ

Q: Can I use this product without the optional DC motion sensor?
A:
Yes, the DC motion sensor is optional. You can use the product without it.

PT-RHB-3CP SERIES
PT-RHB-11D-3CP / PT-RHB-13D-3CP

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

  • TO REDUCE THE RISK OF DEATH, PERSONAL INJURY OR PROPERTY DAMAGE FROM FIRE, ELECTRIC SHOCK, FALLING PARTS, CUTS/ABRASIONS, AND OTHER HAZARDS, PLEASE READ ALL WARNINGS AND INSTRUCTIONS INCLUDED WITH AND ON THE FIXTURE, BOX, AND ALL FIXTURE LABELS.
  • BEFORE INSTALLING, SERVICING, OR PERFORMING ROUTINE MAINTENANCE ON THIS EQUIPMENT, FOLLOW THESE GENERAL PRECAUTIONS:
  • INSTALLATION AND SERVICE OF LUMINAIRES SHOULD BE PERFORMED BY A QUALIFIED LICENSED ELECTRICIAN.
  • MAINTENANCE OF THE LUMINAIRES SHOULD BE PERFORMED BY PERSON(S) FAMILIAR WITH THE LUMINAIRE’S CONSTRUCTION AND OPERATION, AND ANY HAZARDS INVOLVED. REGULAR FIXTURE MAINTENANCE PROGRAMS ARE RECOMMENDED.
  • IT WILL OCCASIONALLY BE NECESSARY TO CLEAN THE OUTSIDE OF THE LENS. FREQUENCY OF CLEANING WILL DEPEND ON AMBIENT DIRT LEVEL AND MINIMUM LIGHT OUTPUT WHICH IS ACCEPTABLE TO USER. LENS SHOULD BE WASHED IN A SOLUTION OF WARM WATER AND ANY MILD, NON-ABRASIVE HOUSEHOLD DETERGENT, RINSED WITH CLEAN WATER AND WIPED DRY.
  • SHOULD OPTICAL ASSEMBLY BECOME DIRTY ON THE INSIDE, WIPE LENS AND CLEAN IN ABOVE MANNER, REPLACING DAMAGED GASKETS AS NECESSARY.
  • DO NOT INSTALL DAMAGED PRODUCT! THIS LUMINAIRE HAS BEEN PROPERLY PACKED SO THAT NO PARTS SHOULD HAVE BEEN DAMAGED DURING TRANSIT. INSPECT TO CONFIRM. ANY PART DAMAGED OR BROKEN DURING OR AFTER ASSEMBLY SHOULD BE REPLACED.

WARNING

  • RISK OF ELECTRIC SHOCK
    MIN 75 °C SUPPLY CONDUCTORS THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

  • RISK OF BURN

    • Allow fixture to cool before handling. Do not touch enclosure or light source.
    • Do not exceed maximum wattage marked on luminaire label.
    • Follow all manufacturer’s warnings, recommendations, and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
  • RISK OF INJURY

    • Wear gloves and safety glasses at all times when removing, installing, servicing or performing maintenance.
    • Avoid direct eye exposure to the light source when fixture is on.
  • RISK OF FIRE

    • Keep combustible and other materials that can burn, away from lamp/lens.
    • Do not operate in close proximity to persons, combustible materials, or substances affected by heat or drying.

INSTALLATION

(ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!)

WIRING DIAGRAM
This LED high bay light can be equipped with optional DC motion sensor,and is available with 0/1-10V dimming function, with following 2 dimming solutions:

  1. 0/1-10V dimming
  2. Intelligent dimming with DC motion sensor

Please use dimming+,dimming-(DC 10V) marking leads to connect outside dimmer. The pink wire and black wire with shrinkable tubing shall not be damaged (no connection). Class 1 Wiring Only. Please assure a cumulative leakage current of less than 3.5mA on the control circuit.

EASILY FLIP THE SWITCH FOR DESIRED CCT/WATTAGE BEFORE INSTALLATION

INSTALLATION OF DC MOTION SENSOR

If fixture has sensor receptacle installed, screw the 1/2” Knockout out with screw driver by illustrated direction, and screw the sensor kit on. The sensor is set as universal mode(refer to sensor spec sheet), the setting is programmable via remote control (the remote control is not included in standard packing)

HOOK MOUNT:

  1. Screw the hook into the fixture. tighten and fix it (Figure 1)
  2. Hang the fixture on the ceiling hook or chain (Figure 2)
  3. After installation,connect the wire of the fixture to the mains according to the local wiring rules,ensure the connection is stable and make good protection on the connection.

CEILING MOUNT:

  1. Mark with a mark pen or sharp tool on the mounting surface and drill (Figure 3).
  2. Fix screw into the hole with a hammer (Figure 4).
  3. Align the bracket hole with screw hole (Figure 5) and push the fixture to one side (Figure 6) and fix it.
  4. After installation, connect the wire of the fixture to the mains according to local wring rules,ensure the connection is stable and make good protection on connection. By adjusting the brackets screws, user can adjust 50° to the left or right vertically (Figure 7).

PENDANT MOUNT:

  1. Unscrew the nuts on 1/2” NTP (Figure 8)
  2. Insert 1/2” NTP stem into the bracket hole (Figure 9)
  3. Re-screw the nuts (Figure 10)
  4. After installation, connect the wire of the fixture to the mains according to local wring rules,ensure the connection is stable and make good protection on connection.

www.portorlighting.com
Specification subject to change without notice

Read User Manual Online (PDF format)