Dimensions
Average Netto Weight
MRUT □□□ □□□ □□□ A004 □□□ □□1 : 3.75 kg
WARNING!
- Do not touch LED modules!
- Do not put any tools or other items on LED modules!
- In case any LED is physically damaged (example shown below) the warranty is void.
LED | Power | CCT | Risk group | Remarks |
---|---|---|---|---|
Oslon Square | 5 … 75 W | ≤ 5700 K | RG1 after 2,11m | Label required |
Luxeon 5050 | 5 … 75 W | ≤ 5700 K | RG1 after 1,85m* | Label required |
The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than shown in the table above is not expected.
Acceptable luminaire with ZHAGA socket mounting angle relative to the ground.
Acceptable luminaire mounting angle relative to the ground.
Unacceptable luminaire mounting angle relative to the ground.
Standard configuration
Configuration with terminal block
Watertight cable connector has to be ordered separately
Article | Description |
---|---|
70000313 | Terminal block, 2-pole + PE |
70000304 | Terminal block, 4-pole + PE |
Configuration without cable
ATTENTION! In case of NEMA Socket.
IP66 applies only for luminaire body and for connection between luminaire
body and NEMA Socket, and do not applies to any mounted control device and
connection between control device and NEMA Socket.
Terms of use and maintenance
Before luminaire is turned on, it should be mounted according with this mounting instruction or any other applicable regulations.
Mounting instructions
Mounting instructions
Mounting of luminaire must be performed by a qualied person according with following instructions:
- The warranty of luminaire does not apply, if the mounting of luminaire has been performed in precipitation (rain, snow, hail).
- The warranty of luminaire does not apply, if a control system unauthorized by VIZULO or an inapplicable LED driver has been used to drive the luminaire.
- The warranty of luminaire does not apply, if it has been used in an unsuitable ambient temperature or has been supplied by voltage outside of the specified range.
- The warranty of luminaire does not apply, if the LED driver program has been changed in any way.
- The warranty of the luminaire does not apply, if the logged history data of the LED driver has been deleted without the permission of VIZULO.
- The warranty of luminaire does not apply, if it has been mounted in unspecified angles or upside down (luminaire glass directed up), or it has been completely submerged under water.
Safety instructions
Any actions with the luminaire must be performed by a qualified person, who is
certified according with national regulations and requirements.
To prevent any accidents person installing the luminaire must follow national
safety requirements and following instructions:
- The label containing technical parameters of the luminaire has to be studied before the work on it has begun.
- Any luminaire build or design changes are prohibited.
- The luminaire must be used in good technical condition and according with this instruction.
- Only VIZULO authorized spare parts and accessories can be used to repair the luminaire.
- The repair of luminaire has to be performed by a qualified and certified person.
Maintenance and repair
Luminaire has to be disconnected from electrical grid before it is opened and/or repaired!
- The person working with the luminaire must follow national regulations and legislations that apply to maintenance and testing of electrical or electronic appliances.
- The luminaire may need to be cleaned depending on its environment. Only a damp cloth or a sponge may be used to clean the luminaire. Use only household detergents diluted by water.
- Only VIZULO authorized spare parts may be used for the luminaire.
- Instruction for changing spare parts must be requested from VIZULO and studied before the repair is attempted.
- LED modules, lens and LED drivers can be changed on an installed luminaire, but it is advised to perform this task indoor to avoid water entering the luminaire.
- Spare parts (lens, LED modules and drivers) should be ordered from the information available on the luminaire label.
MCB/Inrush current table
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>