GYS TRIMIG350 G DV MIG MAG Welding Machine User Manual
- June 17, 2024
- GYS
Table of Contents
- GYS TRIMIG350 G DV MIG MAG Welding Machine
- Product Information
- Product Overview
- Description
- Device Presentation
- SEMI-AUTOMATIC WELDING
- REEL AND TORCH ASSEMBLY
- CONTROL PANEL
- ADVICE and THERMAL PROTECTION
- Maintenance
- SAFETY
- TROUBLESHOOTING
- CIRCUIT DIAGRAM
- SPARE PARTS
- Warranty Conditions
- Declaration Of Conformity
- SYMBOLS
- Accesories
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GYS TRIMIG350 G DV MIG MAG Welding Machine
Product Information
Specifications
- Electricity Supply: 230V 3-phase power supply
- Device Presentation: Earth cable connector, Gas bottle support (max 1 bottle of 10m3), Fastening chain for bottles
- Welding Modes: Semi-automatic welding for Steel/Stainless Steel (MAG Mode), Semi-automatic welding for Aluminium (MIG Mode), Semi-automatic brazing for High-Tensile Strength Steels
- Reel and Torch Assembly: Choice of reels, Wire type settings (Steel, Stainless, Alu AG5), Gas coupling instructions
- Control Panel: Welding mode selection, Wire speed selection, SPOT/DELAY setting potentiometer
- Manual Mode: Adjusting welding voltage using power switches
- Synergic Mode: Settings for thermal protection, duty cycle, and welding environment
- Maintenance: Safety precautions
FAQ
- Q: Can I use the Trimig 250-4S DV, 350 G DV, and 350-4S DUO DV models with a 230V three-phase power supply?
- A: Yes, but you must modify the connection on the terminal board. Refer to the technical diagram inside the product and ensure it is done by qualified personnel.
- Q: How many gas bottles can the device support?
- A: The device can support a maximum of 1 gas bottle with a capacity of 10m3.
- Q: What type of contact tip should I use for Aluminium welding?
- A: Use the specific Aluminium contact tip corresponding to the diameter of the wire.
- Q: What are the duty cycle and maximum current for different Trimig models?
- A: Trimig 200-4S: I max 200A @ 30%, 60% 140A, 100% 120A
- Trimig 250-4S: I max 250A @ 30%, 60% 180A, 100% 140A
- Trimig 300-4S: I max 300A @ 35%, 60% 240A, 100% 180A
- Trimig 350-4S DUO: I max 350A @ 35%, 60% 270A, 100% 220A
Product Overview
Description
Thank you for choosing this product; please read this instruction manual carefully before installing and using the product and keep in a safe place for future reference. The Trimig are semi-automatic welding units; they are ventilated for semi-automatic welding (MIG or MAG) and are capable of welding steel, stainless steel and aluminium. Adjustment is quick and easy with their «synergic wire speed» function. They work on a 400V three-phase power supply, and /or 230V three-phase for the DV models.
Electricity Supply
The absorbed current (I1eff) is indicated on the device for use at maximum settings. Check that the power supply and its protection (fuse and/or circuit breaker) are compatible with the current needed during use. The device must be placed in such way that the power socket is always accessible. Do not use an extension cable which has a wire section smaller than 4 mm².
These products are supplied with a 16A or 32A plug type EEC RS/015. They should be plugged in to a 400V (3PH) power socket WITH earth and protected by a 16A circuit breaker and 1 differential 30mA. 230V 3-phase power supply, for Trimig 250-4S DV, 350 G DV and 350-4S DUO DV:
WARNING: This device is pre-built in 400V three-phase. If your electrical installation is 230V three-phase, you must modify the connection on the terminal board. This modification must be undertaken by qualified personnel. In order to do so, please refer to the technical diagram inside the product. The plug must be protected by a 16A or 25A (for models 350) circuit breaker and 1 differential 30mA.
Device Presentation
device presentation (fig ii)
- On / Off switch
- Power Settings – 2 switches with 7 positions: for adjustment of the welding voltage output. The adjustment of the output voltage is proportional to the thickness of the work piece.
- Control panel – Welding settings (manual or automatic mode).
- European standard torch connection.
- Thermal Protection light: Indicates when a cool-down period is necessary following intensive use.
- Torch support.
- Power Cable (5m).
- Earth cable connector
- Gas bottle support (max 1 bottle of 10m3).
- Fastening chain for bottles.
- Warning: fasten the chain securely (see IV-1)
- Reel support Ø 200 mm/ 300mm.
- Gas connector (350-4S DUO DV)
- Torch Cable support
- Wire feeder solenoid valve 2
- Wire feeder gas connection for torch 2
- Wire feeder control cable connector
- Wire feeder power cable connector
- Selection switch potentiometer (only on 300G and 350 G DV)
SEMI-AUTOMATIC WELDING
SEMI-AUTOMATIC WELDING FOR STEEL / STAINLESS STEEL (MAG MODE) (fig iii)
The Trimig 200-4S can weld 0.6/0.8/1mm steel and stainless steel wires (fig. III-A). The device is capable of working with Ø 1.0 mm steel wire (roller Ø 0.8/1.0, contact tip of 01.0). If using lower diameter wire, you should use change the contact tip, and ensure that the reversible rollers in the wire feeder are positioned correctly (so that required diameter is visible when in place). The Trimig 250-4S DV 230-400V can weld 0.8/1/1.2mm steel and stainless steel wires.
The device is capable of working with Ø 1mm steel wire (roller Ø 0.8/1.0, contact tip of 1). The Trimig 300-4S, 300 G, 350-4S DUO DV and 350 G DV can weld 0.8/1/1.2mm steel and stainless steel wires. The device is capable of working with Ø 1mm steel wire (roller Ø 1.0/1.2, contact tip of 1). For Steel or Stainless Steel, you will need to use specific gas – Argon + CO2 (Ar + CO2). The proportion of CO2 will vary depending on usage. The gas flow for steel is between 10 and 20L / min depending on the environment and experience of the welder.
SEMI-AUTOMATIC WELDING FOR ALUMINIUM (MIG MODE) (fig iii)
The Trimig 200-4S can weld 0.8mm and 1mm aluminium wires. (fig. III-B). The Trimig 250, 300 and 350 can weld 1mm and 1.2mm aluminium wires. (fig. III-B). To weld aluminium, neutral gas “pure Argon” (AR) is required. For specific gas requirements seek advice from your gas distributor. The gas flow in aluminium should be between 15 and 25 L / min depending on the environment and experience of the welder.
Things to note when welding with Aluminium
- Set the pressure of the rollers to a minimum so as not to crush the wire
- Remove the capillary tube before connecting the aluminium torch
- When welding aluminium use a special aluminium torch with Teflon sheath to reduce friction.
- Do not cut the sheath near the connector! It is used to guide the wire from the rollers (fig III-B).
- Contact Tip: Use the specific Aluminium contact tip corresponding to the diameter of the wire.
SEMI-AUTOMATIC BRAZING FOR HIGH-TENSILE STRENGTH STEELS
The Trimig 200-4S can braze-weld high-tensile strength plates with Cuprosilicium CusI3 wire or Cuproaluminium CuAl8 wire (Ø 0.8 mm and Ø 1 mm). The welder must use a neutral gas: pure argon (Ar). For specific gas requirements seek advice from your gas distributor. The required gas flow is between 15 and 25L / min.
REEL AND TORCH ASSEMBLY
REEL AND TORCH ASSEMBLY (fig iv)
Open the door of the machine.
- Position the reel on to the support (3). To place a 200mm wire reel, first install the adapter (ref. 042889) on the support.
- Adjust the reel brake (4) to avoid the reel movement tangling the wire when welding stops. Be careful not to tighten too much! Then tighten the plastic screw (2) firmly.
- The wire feeder uses double groove rollers (8) (Ø 0.8/ Ø 1 or Ø 1/ Ø 1.2). The visible diameter on the roller when fitted is the one currently in use. For Ø 1 mm wire, use the Ø 1 groove.
- For first use:
- Release the fixing screw of the wire guide (5).
- Place the rollers, and tighten the screws (9).
- Place the wire guide (7) as close as possible to the roller but without touching it, then tighten the fixing screw.
- To select the adjustment of the drive rollers (6) : loosen the knob fully, Start the motor by pressing the trigger of the torch, tighten the knob whilst pressing the trigger until the wire starts to move. Bend the wire where it comes out of the nozzle and hold it in place to stop its progress. The setting is correct when the guide roller slides over the wire, even when it is blocked at the end of the torch.
- Common adjustment of knob (6): scale 3-4 for steel, and scale 2-3 for aluminium.
CHOICE OF REELS
Possible settings:
Wire type | Torch | Gas |
---|---|---|
Steel | Ø 300 | x |
+ CO2
Ø 200| x
Stainless| Ø 200| x
Alu
AG5
| Ø 300| x| Argon pur
Ø 200| x
*Consider Teflon sheath and special aluminium contact tip
GAS COUPLING
- Fit the regulator/flowmeter to the gas bottle and then fit the gas pipe to the connector.
- To avoid gas leaks use the collars provided in the accessories box. Ensure proper maintenance of the gas cylinder in accordance with the attachment of the chain cf. IV-1.
CONTROL PANEL
CONTROL PANEL (fig v)
Welding mode selection (2)
- 2T: two-stage welding
- 4T: 4-stage welding
- SPOT: Spot welding with adjustable spot diameter
Wire speed selection (4)
Wire speed regulator
The speed varies from 1 to 15 m/minute.
SPOT/DELAY setting potentiometer (5)
Manual Mode (1)
In manual mode, the wire speed is determined by the user by adjusting the potentiometer (4).
Synergic Mode (3)
Position the potentiometer (4) in the middle of the « OPTIMAL SYNERGIC » zone
In this mode, the device determines the optimum wire speed according to 3
parameters:
- Voltage
- Wire diameter
- The power mode
It is possible to adjust the speed wire + / -.
“manual” mode (fig v)
- To set your device, proceed as follows:
- Choose the welding voltage using the 2 power switches (2 and 7 positions)
Example:
- For welding Steel – 1 mm with a Ø 0.8 wire, set the switch to «1»
- Adjust the wire speed with potentiometer (4).
Advice
- The wire speed adjustment is often determined by « the noise »: the arc must be stable and emit low crackling.
- If the speed is too low, the arc will not be continuous.
- If the speed is too high, the arc crackles and the wire will push back the torch.
“synergic” mode (fig v)
This function automatically controls the wire speed. There is no need to set the wire speed manually.
- Position the wire speed potentiometer (4) in the middle of the « Optimal synergic » zone.
- Select:
- Wire type (3)
- Wire diameter (3)
- Power setting (switch on the front)
To select the right position in accordance with the thickness of the work- piece, please refer to the “synergic mode” table on the previous page.
From the settings chosen, the Trimig determines the optimum wire speed and the device is ready to weld. It is also possible to adjust the wire speed if necessary by adjusting potentiometer + or – manually (4). The last welding configuration is saved in the memory automatically (wire diameter, wire type, mode).
ADVICE and THERMAL PROTECTION
- Trimig should not be lifted by its handles, torch support, or the top of the machine. When lifting the Trimig, ensure the weight is fully supported at the bottom of the machine. There must be no gas bottle connected during this operation.
- Always respect the basic rules of welding.
- Do not block/cover the ventilation holes of the machine.
- Leave the device plugged in after welding to allow proper cooling down.
- Thermal protection: If the machine becomes too hot, the warning light will illuminate and the machine will stop.
- Cooling will take a few minutes, the length of time will also depend on the external temperature.
DUTY CYCLE and WELDING ENVIRONMENT IN USE
- The welding unit describes an output characteristic of “constant current” type. The duty cycles following the standard EN60974-1 (at 40°C on a 10mn cycle) are indicated in the table below:
x/60974-1 @ 40°C | I max | 60% | 100% |
---|---|---|---|
Trimig 200-4S | 200A @ 30% | 140A | 120A |
Trimig 250-4S | 250A @ 30% | 180A | 140A |
Trimig 300-4S et G | 300A @ 35% | 240A | 180A |
Trimig 350-4S DUO et G DV | 350A @ 35% | 270A | 220A |
Note: The machines’ duty cycle has been tested at room temperature (40°C) and has been determined by simulation.
- These are Class-A devices. They are designed to be used in an industrial or professional environment. In a different environment, it can be difficult to ensure electromagnetic compatibility, due to conducted disturbances as well as radiation.
- These devices comply with IEC 61000-3-12, provided that the power of the short-circuit Ssc is equal to or greater than 3.9MVA (2.8MVA for the Trimig 200-4S) at the interface between the machine and the mains power network. It is the responsibility of the installer or user of the equipment to ensure if necessary by consulting the operator of the mains electricity, that the equipment is only connected to a power supply where the power of short-circuit ssc is equal to or greater than 3,9MVA (2.8MVA for the Trimig 200-4S).
Maintenance
- Maintenance should only be carried out by a qualified person.
- Ensure the machine is unplugged, and that the ventilator inside has stopped before carrying out maintenance work. (DANGER High Voltage and Currents).
- GYS recommends removing the steel cover 2 or 3 times a year to remove any excess dust. Take this opportunity to have the electrical connections checked by a qualified person with an insulated tool.
- Regularly check the condition of the power supply cord. If damaged, it will need to be replaced by the manufacturer, its’ after sales service or a qualified person.
- Ensure the ventilation holes of the device are not blocked to allow adequate air circulation.
- Before each use, check the state of welding cables of the torch and earth clamp (The conductive metal should not be exposed).
SAFETY
Arc welding can be dangerous and can cause serious and even fatal injuries.
Protect yourself and others. Ensure the following safety precautions are taken:
- Arc radiation: Protect yourself with a helmet fitted with filters in compliance with EN169 or EN 379.
- Rain, steam, damp: Use your welding unit in a clean/dry environment (pollution factor ≤ 3), on a flat surface, and more than one meter from the welding work-piece. Do not use in rain or snow.
- Electric choc: This device must only be used with an earthed power supply. Do not touch the parts under high voltage.
- Check that the power supply is suitable for this unit.
- Falls: Do not place/carry the unit over people or objects.
- Burns: Wear protective (fire-proof) clothing (cotton, overalls or jeans).
- Wear protective gloves and a fire-proof apron.
- Ensure other people keep a safe distance from the work area and do not look directly at the welding arc.
- Protect others by installing fire-proof protection walls.
- Fire risks: Remove all flammable products from the work area. Do not work in presence of flammable gases.
- Fumes: Do not inhale welding gases and fumes. Use the device in a well ventilated environment, with artificial extraction if welding indoors.
Additional Precautions: Any welding operation undertaken in…..
- rooms where there is an increased risk of electric shocks,
- Poorly ventilated rooms,
- In the presence of flammable or explosive material,
Use should always be approved by a “responsible expert”, and made in presence
of people trained to intervene in case of emergency.
Technical protection as described in the Technical Specification CEI/IEC 62081
must be implemented. Welding in raised positions should not be undertaken,
except in case of safety platforms use.
People wearing Pacemakers are advised to see their doctor before using this
device.
Do not use the welding unit to unfreeze pipes.
Handle gas bottles with care – there is increased danger if the bottle or its
valve are damaged.
TROUBLESHOOTING
Symptoms | Reasons | Solutions |
---|
The welding wire speed is not constant.
| ****
Cracklings block up the opening.
| Clean out the contact batch or change it and replace the anti-adherence product. Ref.041806
The wire skids in the rollers.
| Control the roller pressure or replace it.
Wire diameter non-consonant with roller.
Covering Wire guide in the torch non- consonant.
The unwinding motor doesn’t operate.
| Reel or roller brake too tight.| Release the brake and rollers.
Electrical supply problem.| Check that the running button is on the position
on.
Bad wire unwinding.| Covering wire guide dirty or damaged.| Clean or replace
Reel brake too tight| Release the brake
No welding current
| Bad connection to the main supply.| See the branch connection and look if
the plug is fed by 3 phases.
Bad earth connection.| Control the earth cable (connection and clamp
condition).
Power contactor inoperative.| Control the torch trigger.
The wire rubs down after the rollers.
| Covering wire guide crushed.| Check the covering and torch body.
Locking of the wire in the torch| Clean or replace.
No capillary tube.| Check the presence of capillary tube.
Wire speed too fast| Reduce the wire speed
The welding cord is porous
| The gas flow rate is not sufficient.| Adjusting flow range 15 to 20 L / min.
Clean the working metal.
Gas bottle empty.| Replace it.
Gas quality non-satisfying.| Replace it.
Air flow or wind influence.| Avert air blast, protect welding area.
Gas nozzle too full.| Clean or replace the gas nozzle.
Bad wire quality.| Use adapted WIRE for MIG-MAG welding.
Surface to weld in bad condtion. (rust, etc, …)| Clean the working parts
before welding.
Very important flashing particules.
| Arc voltage too low or too high.| See welding settings.
Bad earth connection.| Check and place the earth cable to have a better
connection.
Protecting gas insufficient.| Adjust the gas flow.
No gas at the torch output.
| ****
Bad gas connection.
| See if the gas coupling beside the engine is well connected. Check the flowmeter and the solenoid valves.
CIRCUIT DIAGRAM
Trimig 200-4S
Trimig 250-4S
Trimig 300-4S
Trimig 300 G
Trimig 350-4S DUO DV 230-400V
Trimig 350 G DV 230-400V
SPARE PARTS
n° | 200 | 250 | 300 | 350 | |
---|---|---|---|---|---|
1 | 80cm chain | 35067 |
2
| Rear cable support| ****
98854
3
| Front torches support| ****
98853
| ****
98877
4| Handle| 56047
5
| Wire speed adjusting knob| ****
73009
6| SPOT-DELAY button| 73099
7| Control Keyboard| 51916| 51915
8| Interrupteur I/O / I/O Switch| 52461
10| Switch| 7 pos
51072
| 10 pos
51074
| 12 pos
51227
| 7 pos 51054
2 pos 51071
11
| Wire feeder (without roller)| ****
51136
| ****
51257
12| Supply cable| 21475| 21497| 21470
13
| Reel support 15 Kg| ****
71603
14| Front wheels| 71361| 71364
15| Diode bridge| 52190| 52173| 52174| 52221
16| Induction oil| 96076| 96079| 96081| 96083
17| Thermostat| 52101
18| Transformer| 96075| 96078| 96080| 96082
19| Fan| 51006
20
| 200mm diameter wheels| ****
71375
| ****
71376
21| End axis| 71382
22
| Contactor 24V AC 10A| ****
51114
| ****
51107
23
| Control transformer| ****
92994
| ****
96029
| ****
96047
| ****
96029
24| Solenoid valve| 71512
25| Carte de commande / Control card / Steuerkarte / Carta de mando /
Плата управления| 97132C| 97172C
---|---|---|---
26| Display card| 97183C| 97233C
27| Gas pipe (1m)| 95993
28| Collar 10,5| 71225
29
| Earth cable connector (1/4)| ****
51469
| ****
51461
30
| Voltage selection switch 230-400V| ****
–
| ****
75012
| ****
–
| ****
75012
for machines with wire feeder
31
| Gas connector| ****
–
| ****
–
| ****
71699
32
| Wire feeder control connector| ****
–
| ****
–
| ****
94895
33
| Potentiometer selection switch| ****
–
| ****
–
| ****
52464
Warranty Conditions
- The guarantee is only valid if the voucher has been correctly completed by the seller.
- The warranty covers any defect or manufacturing defect for 1 year, from the date of purchase (parts and labor of work).
- The warranty does not cover voltage errors, incidents due to misuse, fall, disassembly or any other damage due to transport.
- The warranty does not cover normal wear and tear of parts (e.g.: cables, clamps, etc.).
In the event of a breakdown, return the device to the GYS company (delivery refused), including:
- This warranty certificate validated by the seller.
- An explanatory note of the fault.
After the warranty, our after-sales service ensures repairs after acceptance of a quote.
After-sales service contact
- Company GYS – 134 Bd des Loges
- BP 4159-53941 Saint-Berthevin Cedex
- Fax: +33 (0)2 43 01 23 75
- Tel: +33 (0)2 43 01 23 68
Manufacturer Warranty
The manufacturer’s warranty only applies to manufacturing or material defects within 12 months displayed after purchase (proof of purchase). After acceptance of the warranty claim by the manufacturer or his representative will carry out a repair and replacement of spare parts free of charge for the buyer. The guarantee period remains unchanged due to the guarantee service being provided.
Exclusion: The warranty does not cover defects caused by improper use, falls or hard impacts as well as through unauthorized repairs or through transport damage that occurs as a result of sending it in for repair, have been caused. No guarantee is given for wearing parts (e.g. cables, terminals, washers, etc.) as well taken over if there are signs of use. Please always provide the device in question with proof of purchase and a brief description of the error Send in exclusively to specialist retailers. The repair will only take place after written acceptance has been received (Signature) of the previously submitted cost estimate by the purchaser. In the event of a warranty service, GYS is responsible exclusively the costs for return shipping to the specialist retailer.
Declaration Of Conformity
The equipment described on this manual is conform to the instructions of low voltage 2006/95/CE of 12/12/2006, and the instructions of CEM 2004/108/CE of the 15/12/2004. This conformity respects the standards EN60974-1 of 2005, EN 50445 de 2008, EN60974-10 of 2007. CE marking was added in 2013.
SYMBOLS
Accesories
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>