ORECK DTX 1400A Dutchtech Hepa Canister Vacuum Cleaner User Guide
- June 16, 2024
- ORECK
Table of Contents
- ORECK DTX 1400A Dutchtech Hepa Canister Vacuum Cleaner
- Product Information
- Specifications
- Important Safety Instructions
- FAQs
- Maintenance and Customer Service
- Accessories Sold Separately
- Warranty
- Troubleshooting Guide
- Assembly
- Operating Instructions
- Replacing Filter Bag
- ADVANCED HEPA FILTER INSTALLATION
- Storage
- CONTACT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ORECK DTX 1400A Dutchtech Hepa Canister Vacuum Cleaner
Product Information
- Product Name: ORECK DTX 1400A DTX 1400B Vacuum Cleaner
- Model Numbers: DTX 1400A, DTX 1400B
- Technology: Electronic Control Silence Technology
- Manufacturer: ORECK Manufacturing Company
- Warranty: 3 years on parts, 10 years on motor (for residential use only)
Specifications
- Part Number: ET511PK
- Accessories: Advanced Hepa Filter (Part Number: 1300HF)
Important Safety Instructions
- Read all instructions before using the vacuum cleaner.
- Keep the vacuum cleaner away from children.
- Use only recommended attachments.
- If the vacuum cleaner malfunctions is damaged or is dropped into water, contact customer service or a service centre.
- Avoid pulling the cord around sharp edges or corners and keep it away from heated surfaces.
- Do not use a vacuum cleaner with a damaged cord.
- Maintain proper airflow by keeping the filters and openings clean and free from dust, lint, and hair.
- Avoid using the vacuum cleaner near open flames, cigarettes, matches, or hot ashes.
- Do not use the vacuum cleaner in areas where explosive or toxic vapours are present.
- Avoid using the vacuum cleaner to pick up flammable substances such as gasoline.
- This vacuum cleaner is for household use only.
FAQs
- Can I oil the motor bearings?
- No, the motor bearings are permanently lubricated and should not be oiled.
- Where can I get additional information or assistance with my ORECK appliance?
- You can contact ORECK customer service at the following numbers:
- USA: 1-800-989-3535
- Canada: 1-888-676-7325
- Can I use the vacuum cleaner with a damaged cord?
- No, do not use the vacuum cleaner with a damaged cord. Contact customer service or a service centre for assistance.
- Can I use the vacuum cleaner near open flames or hot surfaces?
- No, avoid using the vacuum cleaner near open flames, cigarettes, matches, or hot ashes to reduce the risk of fire.
- Can I use the vacuum cleaner in areas with explosive or toxic vapours?
- No, do not use the vacuum cleaner in areas where explosive or toxic vapours are present.
Maintenance and Customer Service
Your ORECK vacuum cleaner is a product of precise engineering. The motor bearings are permanently lubricated and should not be oiled. If you require additional information or have problems with your ORECK appliance, you may call ORECK customer service at:
- USA 1-800-989-3535
- Canada 1-888-676-7325
Please specify the model number and serial/code number which can be found on
the data plate on the bottom of the vacuum.
Save your sales or purchase slip. Should your ORECK appliance require warranty
service in the U.S.A., present this slip to the Authorized Service Center as
your proof of purchase date or, in Canada, call customer service.
Accessories Sold Separately
USA: 1-800-989-3535 CANADA: 1-888-676-7325 ITEM PART #
- Celoc® Hypo-Allergenic Dust Bags, 5 Pack, 1 Motor Filter, 1 Exhaust Filter ET511PK
- Advanced Hepa Filter 1300HF
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER
WARNING
To reduce the risk of fire, electric shock, or injury:
- Do not leave the vacuum unattended when plugged in. Unplug from the outlet when not in use and before servicing.
- Do not use it outdoors or on wet surfaces.
- Do not allow the vacuum to be used as a toy. Close attention is necessary when used by or near children.
- Use only as described in this manual. Use only the manufacturer’s recommended attachments.
- Always turn off this vacuum before connecting or disconnecting either the hose or motorized nozzle.
- The hose contains electrical wires. Do not use if damaged, cut, or punctured. Avoid picking up sharp objects.
- Do not use a damaged cord or plug. If the vacuum is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service centre or call customer
- service at US: 1-800-989-3535
- CANADA: 1-888-676-7325
- Do not pull or carry by cord, use the cord as a handle, close the door on the cord, or pull the cord around sharp edges or corners. Keep the cord away from heated surfaces.
- Hold the plug when rewinding onto the cord reel. Do not allow the plug to whip when rewinding.
- Do not run the vacuum over the cord.
- Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.
- Do not handle the plug or vacuum with wet hands.
- Do not put any objects into openings. Do not use with any opening blocked; keep free of dust, lint, hair and anything that may reduce airflow.
- Keep hair, loose clothing, fingers and all parts of the body away from openings and moving parts.
- Do not use to pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
- Do not use without a filter or bag assembly in place.
- Turn off all controls before unplugging.
- Use extra care when cleaning on stairs.
- Do not use to pick up flammable or combustible liquids, such as gasoline or lighter fluid, or use in areas where they may be present.
- Do not use a vacuum in an enclosed space where flammable, explosive or toxic vapours are given off by oil base paint, paint thinner, or some mothproofing substances, or in an area where flammable dust is present.
- Do not pick up toxic material such as chlorine bleach, drain cleaner, gasoline, etc. with this vacuum.
- Use caution when vacuuming over area rug edges and fringe.
Warranty
ORECK MANUFACTURING COMPANY: (ORECK gives you the following limited warranty
for this product only if it was originally purchased for use, not resale, from
ORECK or an ORECK Authorized Retail Dealer.)
ORECK will repair or replace, free of charge, to the original purchaser, any
part which is found to be defective in material or workmanship within three
(3) years of the date of purchase; and ten (10) years on motor. Any commercial
use of this product will void this limited warranty.
Drive belts, revolving brushes, disposable bags, and other parts subject to
normal wear are not covered by this limited warranty. This limited warranty
does not apply to any part subjected to accident, abuse, commercial use,
alteration, misuse, damage caused by fire or act of God, the use of voltages
other than indicated on the serial number plate of this product or service of
this product by other than ORECK or an ORECK Factory Authorized Service
Center.
ORECK does not authorize any person or representative to assume or grant any
other warranty obligation with the sale of this product.
ORECK’s limited warranty is valid only if you retain proof of purchase from
ORECK or an ORECK Authorized Retail Dealer for this product. If you purchase
this product from any other source, your purchase is “AS IS,” which means
ORECK grants you no warranty, and that you, not ORECK, assume the entire risk
of the quality and performance of this product, including the entire cost of
any necessary servicing or repairs of any defects.
ORECK’s liability for damages to you for any costs whatsoever arising out of
this statement of limited warranty shall be limited to the amount paid for
this product at the time of original purchase, and ORECK shall not be liable
for any direct, indirect, consequential or incidental damages arising out of
the use or inability to use this product.
Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to
you.
ALL EXPRESSED AND IMPLIED WARRANTIES FOR THIS PRODUCT, INCLUDING IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE
LIMITED IN DURATION TO THE WARRANTY PERIOD, AND NO WARRANTIES, WHETHER
EXPRESSED OR IMPLIED, WILL APPLY AFTER THIS PERIOD.
Some states do not allow limitations on the duration of implied warranties, so
the above limitation may not apply to you. This warranty gives you specific
legal rights, and you may also have other rights which vary from state to
state.
Troubleshooting Guide
WARNING: Unplug the cord from the electrical outlet before servicing.
SAVE SERVICE CALLS…CHECK THESE FIRST:
- Is the disposable filter dust bag full?
- Are the pores of the filter dust bag clogged with powder or fine dust?
- Is anything clogging the hose, wands, power nozzle & accessories?
P ROBLEM| P OSSIBLE S OURCE| A REAS TO
C HECK
---|---|---
C LEANER
WILL NOT RUN
| Not plugged in properly.| Be sure the cleaner is firmly plugged into a wall
outlet.
| No electricity in the wall outlet.| Check the electrical source–fuse or
circuit breaker.
| The hose is not connected to the unit.| Connect hose.
| Switch on the Power Handle or unit power pedal is off.| Turn both switches
on.
C LEANER
DOES NOT PICK UP
|
The filter bag is full.
|
Replace the filter bag. See “To Install Filter Bag.”
| Intake & Exhaust Filters are blocked.| Replace Filters. See “Replacing
Intake Filter”, & “Replacing Exhaust Filter”.
| Hose, Wand or Accessories are clogged.| Clear obstruction.
| The suction Control on the Handle is
open.
| Close Suction Control.
P OWER N OZZLE
WILL NOT RUN
| Handle Switch is Off.| Turn the Handle Switch On.
| The brush in the Power Nozzle is clogged.| If the red indicator light
illuminates, remove the clog.
Press the red reset button located on the back of the power nozzle.
ALL OTHER SERVICING SHOULD BE DONE BY AN ORECK AUTHORIZED SERVICE CENTER.
Whenever calling, please be sure to have your model and serial number from the data plate.
Assembly
DTX 1400A Assembly
To assist you in identifying components of your vacuum.
-
Intake
-
Exhaust
-
Advanced HEPA Filter
-
Filter Bag
-
Filter Bag Carrier
-
Bag Full Indicator
-
Power On/Off Pedal
-
Cordwinder Pedal
-
Upholstery Tool
-
Dusting Brush
-
Crevice Tool
-
A Upper Friction Wand
12B Lower Friction Wand -
Standard Nozzle
-
Bare Floor/Carpet Adjustment
-
Standard Handle with Hose
-
Suction Control
-
Motor Filter Grill
-
Motor Filter
-
Exhaust Filter
-
Exhaust Filter Grill
-
Wand Clip
-
Hose Lock
-
Variable Slide Control
-
Handle Park
DTX 1400A Getting Ready for Use
TO ASSEMBLE FRICTION WANDS AND STANDARD NOZZLE
-
Connect the hose by firmly inserting the end of hose into canister intake opening until it clicks.
To disconnect hose, turn hose lock on canister intake to unlock hose and remove. -
Insert smaller end of upper friction wand into larger end of lower friction wand.
-
Firmly press standard handle into upper friction wand.
-
Insert the smaller end of the lower friction wand into the standard nozzle or accessory tools.
DTX 1400B Assembly
To assist you in identifying components of your vacuum.
-
Intake
-
Exhaust
-
Advanced HEPA Filter
-
Filter Bag
-
Filter Bag Carrier
-
Bag Full Indicator
-
Power On/Off Pedal
-
Cordwinder Pedal
-
Upholstery Tool
-
Dusting Brush
-
Crevice Tool
-
Telescopic Wand
-
Standard Nozzle
-
Bare Floor / Carpet Adjustment
-
Indicator Lights
-
Release Pedal
-
Headlight
-
Power handle with hose
-
Power Nozzle ON/OFF Switch /
Unit ON/OFF Switch -
Suction Control
-
Motor Filter Grill
-
Motor Filter
-
Exhaust Filter
-
Exhaust Filter Grill
-
Wand Clip
-
Telescopic Wand with cord management
-
Thumb Saver Handle Release
-
Cord Channels
-
Wand Release Button
-
Plug holder
-
Telescopic Wand Length Adjustment
-
Hose Lock
-
Variable Slide Control
-
Handle Park
-
Power Nozzle
DTX 1400B Getting Ready for Use
-
TO ASSEMBLE POWER NOZZLE AND TELESCOPIC WAND WITH CORD MANAGEMENT.
-
Connect the hose by firmly inserting the end of the hose into the canister intake opening until it clicks.
To disconnect the hose, turn the hose lock on the canister intake to unlock the hose and remove it. -
Insert the telescopic wand into the power nozzle until the button locks. Once assembled, do not disassemble.
-
Insert the power nozzle plug into the plug holder on the upper end of the wand.
-
Press cord into cord channels.
For convenience, do not disassemble for storage. -
Insert power handle into the telescopic wand until button locks.
-
To unlock the wand, step on the release button located on the power nozzle. Gently lean wand back for vacuum use.
-
Extend the telescopic wand by holding telecscopic length adjustment and pulling the power handle.
TO ASSEMBLE TELESCOPIC WAND WITH STANDARD NOZZLE OR ACCESSORIES.
-
Connect the hose by firmly inserting the end of hose into canister intake opening until it clicks.
To disconnect hose, turn hose lock on canister intake to unlock hose and remove. -
Insert power handle into the larger end of the telescopic wand (while holding down the button lock, firmly push the power handle into the wand until seated).
-
Insert the small end of the telescopic wand into either the standard nozzle or accessory tools.
Operating Instructions
Polarized Plug Notice
This product is equipped with a polarized alternating current line plug (a
plug having one blade wider than the other). This plug will fit into the power
outlet only one way. This is a safety feature. If you are unable to insert the
plug fully into the outlet, try reversing the plug. If the plug still fails to
fit, contact an electrician to replace the obsolete outlet. Do not defeat the
purpose of the polarized plug.
Note: The hose must be connected for a unit to operate.
- Pull the plug from the unit and insert it into a wall outlet.
- Press the On/Off pedal located at the rear of the canister to turn it on.
- Turn the handle switch to ( l ) position for the unit only or ( ll ) position for the unit and power nozzle. The On/Off pedal on the canister must be On for the handle switch to operate.
- The standard nozzle is adjustable for use on carpets (without brush) or hard floors (with brush).
- To adjust suction, use the suction control on the handle.
- To adjust the power of the motor, use the slide control on top of the unit.
- Upholstery tool, crevice tool and dusting brush can be found in a storage compartment.
- Small accessories can be used with telescopic wands, friction wands, or handles alone.
Note: Under proper operating conditions the green indicator light on the power nozzle will illuminate. If the roller brush becomes stalled, the red indicator light will illuminate. Remove the clog or source of the stall, and press the red reset button on the back of the power nozzle to continue use.
Replacing Filter Bag
-
Check the bag frequently or when the bag full indicator has been activated.
Note: If picking up fine debris, change the bag more frequently. -
Switch the unit off. Unplug the unit from the wall outlet. Open the cover by lifting the latch in front of the intake.
-
Remove the dust bag by raising the handle on the bag carrier and lifting the carrier out.
-
Remove the bag from the carrier by pulling the cardboard tag. The Saniseal® dust seal will close automatically.
-
Insert a new bag into the carrier by sliding cardboard into slots on the carrier until the bag is fully inserted. Bend the rear part of the dustbag downwards.
-
Replace the carrier into the unit.
Close the cover by pressing it down until it latches. The cover cannot be closed if a bag is not present or inserted properly.
Replacing Motor Filter
- Unplug the unit from a wall outlet. Remove the dustbag and carrier to access the motor filter grill.
- Using the tab located at the top of the filter grill, lift the filter grill out of the unit.
- Remove the filter from the grill and replace it with the new filter. Change the motor filter every fifth dustbag replacement.
Replacing Exhaust Filter
- Unplug unit from a wall outlet. Remove exhaust grill from the back of the unit by pressing down and pulling out on the tab located at the top of the grill.
- Discard the used exhaust filter. Place the new filter in the grill. Set grill tabs in slots. Press the top of the grill to snap closed. The exhaust filter should be changed with every fifth dustbag replacement.
Note: Exhaust filter not needed if Advanced Hepa A filter is used.
ADVANCED HEPA FILTER INSTALLATION
-
Remove exhaust grill. Install Advanced Hepa Filter by aligning tabs in slots and pressing the top to snap closed.
-
After the filter has snapped into place, push the filter upwards.
Note: Replace Hepa Filter once a year or every fifth dust bag replacement.
Storage
- Turn the unit off and unplug the cord from the outlet. Rewind the cord by pressing the cord rewind pedal. Do not allow the plug to whip when rewinding.
- When storing DTX 1400A, stand the vacuum cleaner on the end. Insert the telescopic wand clip into a slot located on the base of the vacuum.
- The power nozzle assembly connected or disconnected will stand in an upright position.
CONTACT
- USA: 1-800-989-3535
- CANADA: 1-888-676-7325
- WWW.ORECK.COM
- VISIT ONE OF OUR OVER
- 450 STORE LOCATIONS
©2008 Oreck Holdings, LLC. All rights reserved. All word marks, logos, product configurations, and registered trademarks are owned and used under the authority of Oreck Holdings, LLC. Printed in America.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>