Product Information
Specifications
- Product Name : LED Spike Light
- Model Number : 623HT
- Connection Type : Wired
- Date of Manufacture : 21/11/2019
- Manufacturer Website : https://manual-hub.com/
Product Usage Instructions
Connecting to an Outdoor Rated Terminal Block
If you plan to connect the LED Spike Light to an approved outdoor rated
terminal block, follow the steps below
- Ensure that the terminal block is suitable for outdoor use and meets the necessary safety standards.
- Identify the wiring diagram provided in the user manual or on the product itself.
- Prepare the necessary tools, including wire strippers and a screwdriver.
- Strip the insulation from the wires according to the specified length in the wiring diagram.
- Insert the stripped wires into the appropriate terminals of the terminal block.
- Tighten the screws on the terminal block to secure the wires in place.
- Double-check the connections to ensure they are secure and properly aligned.
Note : It is crucial to follow the wiring diagram and ensure proper wire color coding to avoid any electrical issues or malfunctions.
Frequently Asked Questions (FAQ)
-
Q: Can I use the LED Spike Light indoors?
A: Yes, the LED Spike Light can be used both indoors and outdoors. However, please ensure that the appropriate wiring and connections are made according to the intended use. -
Q: Is the LED Spike Light waterproof?
A: The LED Spike Light is designed to be used outdoors and is typically weatherproof. However, it is important to check the product specifications and IP rating to ensure it is suitable for the specific outdoor conditions in your area. -
Q: Where can I find the complete user manual for the LED Spike Light?
A: The complete user manual for the LED Spike Light can be found on the manufacturer’s website at https://manual-hub.com/. Please refer to the manual for detailed instructions on installation, maintenance, and troubleshooting.
LED Spike Light
623HT
Wiring
If connecting to an approved outdoor rated terminal block, wire as shown
below.
Check that
- You have correctly identified the wires.
- The connections are tight.
- No loose strands have been left out of the connection block
Care and Safety
- We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
- For your safety, always switch off the power supply before cleaning.
This LED’s are protected by a plastic lens. The lens part must be replaced immediately should it become cracked or damaged. This fitting must not be used without the plastic lens in place.
Installation
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires.
- Note that the power needs to be isolated/switched off at the fuse board.
- Plan the desired layout of this fitting carefully, ensuring the cables will reach the distance between the junction box and the light fitting.
- Decide on the position of the luminaire. Depending on the location, an approved outdoor rated plug and socket may be required. Alternatively an approved outdoor rated external terminal block may be used.
- Avoid locating any cables in positions that would cause a hazard. Position cables and connector block away from areas where they may be at risk from being cut, trapped or damaged.
- Ensure that the ground is suitable for pushing the spike into, and can support the luminaire. Do not install in very wet or boggy areas.
- Power-on Your light is now ready for use
Plug Fitting
Alternatively, the product can be connected to a 3 pin plug.
- The appliance must be connected to a 240 volts AC supply.
- The appliance can be fitted to a rewireable 3 pin plug fitted with a 3 amp fuse. Should the fuse require replacement, it must be replaced with a fuse rated at 3 amp and approved to BS1362.
- If the mains plug is unsuitable for the socket outlet or is removed for any other reason, then the cut off plug should be disposed of safely to prevent the hazard of electric shock.
- There is a danger of electric shock if the cut off plug is inserted into any 13 amp socket outlet.
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
- Please read these instructions carefully before commencing any work.
- This unit must be fitted by a competent and qualified electrician.
- Install in accordance with IEE Wiring regulations and current Building Regulations.
- Check the pack and make sure you have all of the parts listed.
- To prevent electrocution switch off at mains supply before installing or maintaining this fitting.
- Ensure other persons cannot restore the electrical supply without your knowledge.
- This light fitting should be connected to a fused circuit.
- If replacing an existing fitting, make a careful note of the connections.
- This product is unsuitable for immersion in water.
- Cables must be protected using suitable conduit or plastic trucking.
- The mains supply cable must have a minimum cross sectional area of 1.0mm.
- This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.
- Take care not to drill into any pipes or mains cables beneath the surface during mounting holes preparation.
- The distance between the cable entry and the ground surface should be at least 10cm when installing the spike.