UEi DT20A Dual Input Thermistor Calright Instruction Manual
- June 16, 2024
- UEi
Table of Contents
- UEi DT20A Dual Input Thermistor Calright
- Product Usage Instructions:
- FAQ
- Introduction
- Controls and Indicators
- Operating Instructions
- Maintenance
- Battery Replacement
- Troubleshooting
- Specifications
- Standard & Optional Accessories
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
UEi DT20A Dual Input Thermistor Calright
Specifications
- Model: DT15A/DT20A
- Type: Dual input thermistor-type thermometer
- Probes: Two replaceable probes
- Display: Large backlit digital display
Product Information
The DT15A/DT20A is a dual-input thermistor-type thermometer that offers
economy and convenience. It features two replaceable probes for easy and
precise measurements. The thermometer also comes with a large backlit digital
display, which stands out in comparison to its compact design.
Product Usage Instructions:
Safety Notes
Before using this meter, read all safety information carefully. The word
“WARNING” is used to indicate conditions or actions that may pose physical
hazards to the user. The word “CAUTION” is used to indicate conditions or
actions that may damage the instrument.
WARNING! Always be aware of hazardous surroundings while operating this instrument.
Controls and Indicators
-
Power Push-button: Used to turn the power to the meter on oroff. MIN/MAX Push-Button: Displays the captured minimum and maximum
values for all parameters. -
Degrees Celsius
-
T1-T2 Push-button (DT20A only): Toggles screen information between T, T2, and T1-T2.
-
Thermistor Ports: 1/8 mini jack plugs for the thermistor probes used; T1 on the left, T2 on the right for DT20A.
-
LCD Display: Display screen of function and data information.
-
Second Display (DT20A only): Displays T2 or T1-T2 data.
NOTE: DT20A shown. DT15A does not have a dual display or T1-T2 button.
Operating Instructions
The meter will momentarily flash all LCD segments on the display when it is
first turned on, emit four quick beeps, and then go blank for approximately 3
seconds before starting operation. The instrument will only provide
information with probes plugged in. The DT20A has a split screen to view both
T1 and T2, or T1-T2, and your choice of either T1 or T2. Numerous viewing
combinations are available to ensure you get the information you need.
NOTE: If no probes are plugged in, three dashes will appear in the
temperature data screens. This will also be recorded as a Max until the power
is switched off, then back on. This instrument operates and updates silently.
Auto Power Off
This instrument will shut off automatically in approximately 60 minutes. To
defeat the auto power-off function for recording or operating over longer
periods of time, hold down the hold button while turning the unit on. The unit
will start with one solid beep to indicate that the auto power-off function is
not activated.
More Options
When the instrument is initially turned on, the primary screen displays T1
and the secondary screen displays T2 (DT20A). The following table lists the
modes of operation that can be invoked by pressing the buttons indicated. The
table assumes your instrument has been powered on with temperature probe(s)
installed:
Button | Function |
---|---|
ON/OFF | Turns the power to the meter on or off |
MIN/MAX | Displays the captured minimum and maximum values for all |
parameters
Back Light| Controls the backlight of the display
Hold| Freezes the current display
Maintenance
WARNING! Repair and service of this instrument should only be performed
by qualified personnel. Improper repair or service could result in physical
degradation of the meter and alter the protection it provides to the
operator. Perform only those maintenance tasks that you are qualified to do.
FAQ
Q: How long does the auto power-off function take to activate?
A: The auto power-off function activates after approximately 60 minutes of
inactivity.
Q: Can I view both T1 and T2 simultaneously on the DT15A?
A: No, the DT15A does not have a dual display feature. It can only display
one temperature reading at a time.
1-800-547-5740 • Fax: 503-643-6322 www.ueitest.com • email: info@ueitest.com
Introduction
The DT15A/ DT20A gives you economy and convenience in a dual-input thermistor-
type thermometer. It has two replaceable probes for easy, precise measurements
and a large backlit digital display that stands out in comparison to its
compact design.
Features include
- -58° to 571°F (-50° to 300°C)
- Dual probe inputs
- The dual display lets you monitor any two of T1, T2, or differential (ΔT)
- MIN/MAX record
- High visibility backlit display
- Data hold
- Includes two replaceable, submersible metal probes
Safety Notes
Before using this meter, read all safety information carefully. In this
manual, the word “ WARNING ” is used to indicate conditions or actions
that may pose physical hazards to the user. The word “ CAUTION ” is used
to indicate conditions or actions that may damage this instrument.
- Do not attempt to use this meter if either the meter or the test leads have been damaged. Turn it in for repair at a qualified repair facility
- Place ONLY thermistor probes in input jacks
- Be sure the probe you are using can withstand the temperature extreme it may be exposed to
- Properly maintain your thermometer and ca l i b rate it regularly
WARNING! Always be aware of hazardous surroundings while operating this instrument.
Controls and Indicators
- Power Push-button: Used to turn the power to the meter on or off.
- MIN/MAX Push-Button : Displays the captured minimum and maximum values for all parameters.
- Back Light Push-Button “ “: Powers backlight on and off.
- Hold Push-button: Freezes screen data.
- °F/°C Select: Toggles display data from degrees Fahrenheit to degrees Celsius.
- T1-T2 Push-button (DT20A only): Toggles screen information b e tween T, T2, and T1-T2.
- Thermistor Ports : 1/8” mini jack plugs for the thermistor probes used; T1 on the left and T2 on the right for DT20A.
- LCD Display : Display screen of function and data information.
- Second Display (DT20A only): Displays of T2 or T1-T2 data.
NOTE: DT20A shown. DT15A does not have a dual display or T1-T2 button
Operating Instructions
Functional Description
The meter will momentarily flash all LCD segments on the display when it is
first turned on, emit four quick beeps the it will go blank for approximately
3 seconds before starting operation. The instrument will only provide
information with probes plugged in. The DT15A has a single screen of
information to view the temperature in °F or °C, recorded minimum or maximum,
or held value. The DT20A has a split screen to view both T1 and T2, or T1-T2,
and your choice of either T1 or T2. The choices for format are the same as
with the DT15A. Numerous viewing combinations are available to ensure you get
the information you need.
- MIN/MAX function starts when the meter is powered on, and continues to capture values while operating with probes connected
- Temperature readings are easily toggled between Fahrenheit and Celsius
- The backlight illuminates the LCD for viewing in low-light areas
- The HOLD button will freeze the display data and suspend the MIN/MAX function
- The display will begin to blink when the battery voltage is low
NOTE : If no probes are plugged in, three dashes will appear in the temperature data screens. This will also be recorded as a Max until the power is switched off and then back on. This instrument operates and updates silently.
Auto Power Off
This instrument will shut off automatically in approximately 60 minutes. For
recording or operating over longer periods of time you can defeat the auto
power-off function by holding down the hold button while turning the unit on.
the unit will start with one solid beep to indicate that the auto power-off
function is not activated.
More Options
Maintenance
Periodic Service
WARNING! Repair and service of this instrument is to be performed by
qualified personnel only. Improper repair or service could result in physical
degradation of the meter. This could alter the protection this meter provides
to the operator. Perform only those maintenance tasks that you are qualified
to do.
Cleaning
Periodically clean your meter’s case using a damp cloth. DO NOT use abrasive,
flammable liquids, cleaning solvents, or strong detergents as they may damage
the finish, impair safety, or affect the reliability of the structural
components. Do not allow moisture to directly contact the temperature probe
jacks, or enter the instrument’s housing. Remove the instrument from its boot
to ensure moisture is not trapped during cleaning.
Battery Replacement
Always use a fresh replacement battery of the specified size and type. Immediately remove the old or weak battery from the meter and dispose of it in accordance with your local disposal regulations. Batteries can leak chemicals that corrode electronic circuits. If your meter is not going to be used for a month or more, remove and store the battery in a place that will not allow leakage to damage other materials. To install a new battery, follow these procedures:
- Remove the temperature probes from the top of the instrument.
- Remove the rubber boot, by sliding the instrument out toward the top faceplate cut-out.
- Lay the instrument face down on a clean, flat surface.
- Remove the battery cover by sliding it straight down.
- Remove and replace the batteries, observing the indicated polarity. Calibration
To ensure your instrument is performing at its peak, send it to the UEi factory or a qualified calibration facility for annual calibration.
Troubleshooting
This instrument contains no user-serviceable parts beyond those listed in this table. In the event your instrument is physically damaged or does not function properly after taking the listed action, please return the instrument to UEi following the warranty and service instructions.
Specifications
Specifications are for operating temperatures between 64 and 77°F (18 to 25°C). Specifications are valid for 1 year after calibration.
Operating Conditions
32° to 122°F (0° to 50°C) at 0 to 85% relative humidity (non-condensing).
Standard & Optional Accessories
Standard
Temperature Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . .ATT55A
Optional
Air Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . .ATT56A
Surface Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . .ATT57A
Soft Carrying Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . .AC319
Limited Warranty
The DT15A/ DT20A is warranted to be free from defects in materials and
workmanship for a period of three years from the date of purchase. If within
the warranty period, your instrument should become inoperative from such
defects, the unit will be repaired or replaced at UEi’s option. This warranty
covers normal use and does not cover damage that occurs in shipment or failure
that results from alteration, tampering, accident, misuse, abuse, neglect, or
improper maintenance. Batteries and consequential damage resulting from failed
batteries are not covered by warranty. Any implied warranties, including but
not limited to implied warranties of merchantability and fitness for a
particular purpose, are limited to the express warranty. UEi shall not be
liable for loss of use of the instrument or other incidental or consequential
damages, expenses, or economic loss, or for any claim or claims for such
damage, expenses, or economic loss. A purchase receipt or other proof of the
original purchase date will be required before warranty repairs will be
rendered. Instruments out of Warranty will be repaired (when repairable) for a
service charge. Return the unit postage paid and insured to:
- 1-800-547-5740 • FAX: 503-643-6322
- www.ueitest.com • Email: info@ueitest.com
This warranty gives you specific legal rights. You may also have other rights which vary from state to state.