UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case User Guide

June 6, 2024
UEI TEST INSTRUMENT

UEI logo

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig1

OVERVIEW

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig2 UEI TEST INSTRUMENT C165
Commercial Combustion Analyzer with Case fig3

MENU SCREEN – C165+ START UP

  • Press ”Power” Button for 2 seconds. The analyzer will perform a 10 second purge. This should be done in fresh air.
  • Rotate Selector Dial to MENU to set up or customize your settings.
  • Selected parameter are highlighted with Display Line Lights on either side.
  • Use UP and Down ARROW BUTTONS to scroll menu options.
  • Press UP and Down ArrowButton to edit a parameter.
  • Press and ARROW BUTTONS to change contents of field.
  • Press Back Button to enter content and move to next

STATUS SCREEN

Rotate Selector Dial to STATUS to view parameters

  • Ta
  • ATM
  • CAL
  • DATE
  • TIME
  • BATTERY LEVEL

Change Fuel Type

  • With the first line selected press UP and Down ARROW
  • BUTTONS to change currently selected Fuel. (NAT
  • GAS, H OIL, PELLETS, mmHG, PSI, kPA, PA, mmH2O, mBar)
  • Press Back Button to select.

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig1

BEFORE TESTING

CHECKLIST

  • Clean particle filter
  • Water trap and probe line are free of condensate
  • All hose and thermocouple connections are properly secured
  • Water trap is fitted correctly
  •  Power on and zero
  • Flue gas probe is sampling ambient FRESH air

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig6

AUXILIARY SCREEN

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig7

BASIC CO/COMBUSTION ANALYSIS

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig8

Once complete, remove probe from stack, allow analyzer to purge in fresh air until CO sensor readings return to ZERO (0) and O2 readings reading return to 20.9%.Continue to the next test or power analyzer off by pressing , if finished.
NOTE: Print and store functions may be used at any time during testing.

PRESSURE TEST

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig10

TEMPERATURE TEST

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig11

HEAT EXCHANGER TEST

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig12 UEI TEST
INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig13

ROOM CO TEST

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig14

PRINTING AND LOGGING

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig15

SETUP USER FUEL

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig16

POST TESTING

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig17

POWERING OFF
When you power off the C165+, there is a 10 second purge.

CAUTION
Make sure you do not exceed the analyzer’s operating specifications.

  • Do not exceed the flue probes maximum temperature (1112˚F)
  • Do not exceed the analyzer’s internal temperature range 112°F (50°C)
  • Do not put the analyzer on a hot surface
  • Do not exceed the water trap’s level
  • Do not let the particle filter become dirty and blocked

BATTERIES

UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case
fig18

WARNING
Do not recharge with Alkaline batteries fitted. Alkaline batteries are not rechargeable. Attempting to recharge alkaline batteries may result in product damage and create a fire risk. Time and Date will need to be reset after changing batteries.
Always dispose batteries using approved disposal methods that protect the environment.

WARRANTY
The C165+ combustion analyzer is warranted for one year. Warranty is a manufacturing defect identified
within the product’s warranty period. Warranty does not cover batteries, fuses, test leads, probes, consumables physical damage and misuse. For full warranty details please refer to the Owner’s Manual on the C165+ product page (see the link above). If a UEi product fails under warranty, we will replace it but we need the unit back so we can identify and fix the problem. For an RMA call Team UEi @ 1-800- 547-5740.
This warranty gives you specific legal rights. You may also have other rights which vary from state to state.

ANNUAL RECERTIFICATION SERVICES

Complete care for your C160 series combustion analyzer.

When you:
Request Recertification or Service Online Within 1 Year of Purchase or Service

UEi will:
6-Year Warranty: All UEi combustion analyzers have a standard 1-year warranty. Each recertification includes a 30-point inspection and extends the warranty for 1 more year for up to 6 years from the
date of warranty.
24-hour Service: Analyzers received for standard recertification and service through UEi Service+ are shipped back on the next business day.
Free Shipping:
UEi Service+ offers free shipping both to and from our service center. When customers book their recertification, they
receive a prepaid UPS Ground shipping label.

Register Online
Registering you analyzer online is quick and easy. Just log in or setup an account, it only takes a couple of minutes. Once logged in you can register you analyzer by providing some product information and uploading a proof-of- purchase.
When it’s time to request recertification, just log into your account, select the analyzer, select the service and place your order.

TestEquipmentDepot.com

Documents / Resources

| UEI TEST INSTRUMENT C165 Commercial Combustion Analyzer with Case [pdf] User Guide
C165 Commercial Combustion Analyzer with Case, C165, Commercial Combustion Analyzer with Case
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

UEI TEST INSTRUMENT User Manuals

Related Manuals