RENOGY RSHGWSN W02W G2 One Core Power Monitor User Guide

June 16, 2024
Renogy

RENOGY Logo RENOGY ONE
Core
RSHGWSN-W02W-G2RENOGY RSHGWSN W02W G2 One Core Power
Monitor QUICK GUIDE

Before Getting Started

The quick guide provides important operation and maintenance instructions for Renogy ONE Core (hereinafter referred to as Core).
Read the quick guide carefully before operation and save it for future reference. Failure to observe the instructions or precautions in the quick guide can result in electrical shock, serious injury, or death, or can damage the Renogy ONE Core, potentially rendering it inoperable.

  • Renogy ensures the accuracy, sufficiency, and the applicability of information in the quick guide at the time of printing due to continual product improvements that may occur.
  • Renogy assumes no responsibility or liability for personal and property losses, whether directly and indirectly, caused by the user’s failure to install and use the product in compliance with the quick guide.
  • Renogy s not responsible or liable for failures, damages, or injuries resulting from repair attempted by unqualified personnel, improper installation and operation.
  • Theillustrations in the quick guide are for demonstration purposes only. Details may appear slightly different depending on product revision and market region.
  • Renogy reserves the right to change the information in the quick guide without notice. For the latest quick  guide, visit renogy.com.

onine Manual

RENOGY RSHGWSN W02W G2 One Core Power Monitor - QR
Cord

https://store-7q1w4er834.mybigcommerce.com/content/manual/Renogy%20ONE %20Core-quick%20guide.pdf| https://store- 7q1w4er834.mybigcommerce.com/content/manual/Renogy%20ONE%20Core_User%20Manual.pdf

what’s In the Box?

Get to Know RENOGY ONE Core

RENOGY RSHGWSN W02W G2 One Core Power Monitor - Bubble

Installation Site and Environment

RENOGY RSHGWSN W02W G2 One Core Power Monitor -
Environment

NOTE

  • To enable the RV leveling function on Renogy ONE Core, ensure it is installed in a spot with the screen pointing to the front, rear, left, or right side of the RV, vertically to the RV floor. It is recommended that RV leveling blocks should be used during the leveling process.

Required Tools

RENOGY RSHGWSN W02W G2 One Core Power Monitor - Required
Tools

NOTE

  • Tools are required only when the Core is flush mounted on a wall.
  • You can use either a skill saw or an electric drill with hole saw.

Step 1 (A). Place Renogy ONE Core on a Table

The package box s environmentally friendly. You can use it as a bracket to hold the Core when installing it on the wall is not required.

RENOGY RSHGWSN W02W G2 One Core Power Monitor - Renogy

  NOTE

  • The RV leveling function is unavailable on Core when it is placed on a table.

Mounting Template

Please tear off this piece of paper and paste it to the mounting location for drilling holes.

RENOGY RSHGWSN W02W G2 One Core Power Monitor -
Template Step 1 (B). Mount Renogy ONE Core on a wall

NOTE

  • You can also use another piece of paper as the mounting template. The installation hole comes in 2,17 in x 2.17in (55 mm x 55 mm).

RENOGY RSHGWSN W02W G2 One Core Power Monitor - Renogy
OneRENOGY RSHGWSN W02W G2 One Core Power
Monitor - Renogy One 1

Step 2. Connect Renogy ONE Core to a Power Supply included).
You can connect Renogy ONE Core to a power supply through the included power cable or a Type-C cable (not included).

  • Installed on a WallRENOGY RSHGWSN W02W G2 One Core Power Monitor - Wall
  • Installed on a TableRENOGY RSHGWSN W02W G2 One Core Power Monitor - Table

NOTE

  • When installing the power cable, always connect the negative first, and then the positive.

Step 3. Install a Communication Cable (Optional)

For details, see the Renogy ONE Core User Manual by scanning the QR code in the guide.

RENOGY RSHGWSN W02W G2 One Core Power Monitor -
Devices

step 4. Power on/off

Long press the On/Off Button for 5s to power the Core on or off. Step 5. Pairing with DC Home
For initial startup, follow the startup wizard on the Core to pair it with the DC Home app. Alternatively, go to

System > Pair with App.

RENOGY RSHGWSN W02W G2 One Core Power Monitor - App

Step 6. Add Devices
Renogy ONE Core can connect to Bluetooth, Bluetooth mesh, and Zigbee Renogy devices concurrently.

RENOGY RSHGWSN W02W G2 One Core Power Monitor - Add
Devices

RV Leveling

RENOGY RSHGWSN W02W G2 One Core Power Monitor - RV
Leveling

NOTE

  • RV leveling calibration on Renogy ONE Core is required each time the installation site for the Core is changed

Important Safety Instructions

  • Keep Renogy ONE Core out of the reach of children.
  • Do not dispose of Renogy ONE Core as household waste. Comply with local, state, and federal laws and regulations and use recycling channels as required.
  • Do not expose Renogy ONE Core to flammable or harsh chemicals or vapors.
  • There are no serviceable parts in Renogy ONE Core. Do not open, dismantle, repair, tamper with, or modify it.
  • Confirm the polarities of the devices before connecting Renogy ONE Core to a power supply. A reverse polarity contact can result in damage to the Core, thus voiding the warranty.
  • Ensure that the connected DC power supply rates at 8V to 60V. Connecting the Core to a power source beyond the range results in a power-on failure or permanent damage to the Core.
  • You can use an extended power cable on demand. For details, see Renogy ONE Core User Manual by scanning the QR code in the guide.

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Wamning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if notinstalled and used in accordance with theiinstructions, may cause harmul interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by tuming the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  1. Reorient or relocate the receiving antenna.
  2. Increase the separation between the equipment and receiver.
  3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  4. Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

RSS Statement

This device complies with Industry Canada license exempt RSS standard{s). Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

The device is compliance with RF exposure guidelines, users can obtain Canadian information on RF exposure and compliance. The minimum distance from body to use the device is 20cm.

Renogy Support
To discuss inaccuracies or omissions in this quick guide or user manual, visit or contact us at:
( renogy.com/support/downloads ) contentsenvice@rengy.com

For technical questions about your product in the U.S., contact the Renogy technical support team through:

( renogy.com/contact-us)
1(308)2877111

For technical support outside the U.S., visit the local website below:

Canada carenogy.com
United Kingdom uk.renogy.com
Australia au.renogy.com
South Korea kr.renogy.com
China www.renogy.cn
Japan renogy.jp
Germany de.renogy.com
Other Europe eu.renogy.com

Renogy ONE Core Quick Guide © 2023 Renogy. All rights reserved.
RENOGY and RENOGY are registered trademarks of Renogy.

  • Allinformation in the quick guide is subject to copyright and other intellectual property rights of Renogy and ts licensors. The quick guide may not be modified, reproduced, or copied, in whole or in part, without the prior written permissions of Renogy and its licensors.
  •  The registered trademarks in the quick guide are the property of Renogy. The unauthorized use of the trademarksis trcty prohibited.

Renogy Empowered
Renogy aims to empower people around the world through education and distribution of DIY-friendly renewable energy solutions.
We intend to be a driving force for sustainable living and energy independence.
In support of this effort, our range of solar products makes it possible for you to minimize your carbon footprint by reducing the need for grid power.
: Live Sustainably with Renogy

Did you know? In a given month, a kW solar energy system wilL..
Save 170 pounds of coal from being burned.
Save 300 pounds of CO: from being released into the atmosphere.
Save 105 gallons of water from being consumed.

  Renogy Power PIUS
Renogy Power Plus allows you to stay in the loop with upcoming solar energy innovations, share your experiences with your solar energy journey, and connect with like-minded people who are changing the world in the Renogy Power Plus community.

@Renogy Solar
@renogyofficaial
@Renogy
Renogy reserves the right to change the contents of this manual without notice.

Manufacturer: RENOGY New Energy Co.,Ltd
Address: No.66, East Ningbo Road Room 624-625
Taicang German Overseas Students Pioneer Park
JiangSu 215000 CN
**** eVatmaster Consulting GmbH
Battinastr. 30
60325 Frankfurt am Main, Germany
contact@evatmaster.com

Manufacturer: RENOGY New Energy Co.,Ltd
Address: No.66, East Ningbo Road Room 624-625
Taicang German Overseas Students Pioneer Park
JiangSu 215000 CN
EVATOST CONSULTING LTD
Suite 11, First Floor, Moy Road Business
Centre, Taffs Well, Cardiff, Wales, CF15 7QR
contact@evatmaster.com

FCC ID: 2ANPBGWSN-WO0O3W
HVIN:RSHGWSN-W02W-G2 IC: 23590-RSHGWSNWO3W
RENOGY.COM

Documents / Resources

| RENOGY RSHGWSN W02W G2 One Core Power Monitor [pdf] User Guide
RSHGWSN W02W G2 One Core Power Monitor, RSHGWSN W02W, G2 One Core Power Monitor, Core Power Monitor, Power Monitor, Monitor
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals