sauermann KT 320 Kistock Data Logger Instructions
- June 16, 2024
- sauermann
Table of Contents
- Features
- References
- General features
- Technical specifications
- Dimensions
- Connections
- PC connection
- Optional probes and cables(1)
- Recorder function
- Display
- Mounting
- Replace the battery
- Safety lock wall mount with padlock
- Dimensions of the wall mount (mm)
- Software
- Accessories
- Maintenance
- Calibration
- Precautions for use
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
sauermann KT 320 Kistock Data Logger Instructions
Features
- Software for configuration and data visualisation freely downloadable
- Software for configuration and data processing available in option
- Safety lock wall mount with inviolability system
- Storage capacity of 2,000,000 points · Fast data downloading: 18,000 points/s
- Up to 5 recordable parameters simultaneously
- 2 configurable setpoint alarms for each channel
- 2 lines LCD screen · Wireless connection for smartphones and tablets (Android and iOS)
- Magnetic mounting
References
General features
- Input which allows to plug different compatible SMART PLUG probes: see optional probes and cables page 5.
** With all thermocouple probes connected.
Technical specifications
(1) Some units are available only with optional probes.
(2) Input which allows to plug different compatible probes: see optional
probes and cables page 3.
(3) Other measuring ranges are available according to the connected probe: see
optional probes and cables page 3.
(4) All accuracies indicated in this document were stated in laboratory
conditions and can be guaranteed for measurement carried out in the same
conditions, or carried out with calibration compensation.
(5) The screen can be hard to read, and its display speed often slows down at
temperatures lower than 0 °C. This has no effect on the accuracy of
measurements.
(6) Non-contractual value. Based on 1 measurement each 15 minutes at 25 °C. A
correct operation of the device and the storage conditions must be respected.
Dimensions
Connections
PC connection
Optional probes and cables(1)
All the thermocouple temperature probes for the KTT 320 KISTOCK have a class 1 sensitive element as per IEC 584-1, 2 and 3 standards. For more details about the available thermocouple probes, please see the `’Thermocouple probes” datasheet.
(1) For more details, please see the “Measuring probes for KT 320 KISTOCK” and “Thermocouple probes” datasheets.
Recorder function
Five recording modes KISTOCK can record in 5 different ways:
-
“Immediate” mode records values according to a predefined interval.
-
“Minimum”, “Maximum” and “Average” record automatically the calculation of minimum, maximum or average of measured values during an interval of recording. “Monitoring” mode allows to get an accurate history report during error events to help troubleshooting, without stopping the measurement logging. To proceed this way, you just have to define:
– a record interval to be used whilst the readings are beyond the setpoints
– a record interval for the values measured during each reading beyond the setpoints -
Furthermore, you can also let your KISTOCK record non-stop (“loop” recording option).
Four types of dataset start
Once your recording mode has been set, you can launch your dataset:
- With a delayed start (with predefined date and time)
- With the software · With push-button
- With “Online” option. In this case, your datasets are directly sent, saved and displayed on your PC in real time.
Six types of dataset stop
You can stop your dataset:
- According to a date and time (if it was started the same way)
- According to a period
- According to a predefined number of recording points
- Once the storage capacity is full
- With “Stop” option of the software
- By holding “OK” key during 5 seconds, if this function has been previously activated by the software
Display
Mounting
The KISTOCK class 320 have a magnetic mounting, so you can fix it easily.
Replace the battery
⚠ With 4 years* of battery life, the KISTOCK devices guarantee long-term measurements.
To replace the battery:
-
Unscrew the 4 screws on the back side of the device with a screwdriver.
-
Remove the back side and the old batteries.
-
Insert the new battery and respect the polarity.
-
Replace the back side and the 4 screws
-
Non-contractual value. Based on 1 measurement each 15 minutes at 25 °C. A correct operation of the device and the storage conditions must be respected.
Safety lock wall mount with padlock
- Present the KISTOCK data logger on the support starting with the inferior part
- Clip the KISTOCK on the support by falling back the superior part
- Insert the padlock to ensure the safety lock function
ℹ The padlock can be replaced by a fail-safe sealed.
ℹ The data logger can be placed on the screw-mount without the safety lock
function.
- To remove the data logger from the support, proceed on reverse order.
Dimensions of the wall mount (mm)
Software
Kilog Lite: free software to download on sauermanngroup.com Allows the data
download (graphics and points statement) and the data logger configuration.
Configuration and data processing software KILOG software allows to configure,
save and process your data in a very simple way.
- Software only: Ref. KILOG-3-N
- Complete set: software + 1 USB cable, Ref. KIC-3-N
Accessories
Maintenance
Please avoid any aggressive solvent. Please protect the device and probes from any cleaning produce containing formalin, that may be used for cleaning rooms and ducts.
Calibration
A calibration certificate is available as option in paper format. We recommend to carry out a yearly checking.
Precautions for use
Please always use the device in accordance with its intended use and within parameters described in the technical features in order not to compromise the protection ensured by the device.
⚠ BE CAREFUL! Material damages can happen, so please apply the precautionary
measures indicated.
sauermanngroup.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>