400W LED Intelligent Dimmer
PDM400 400W LED Intelligent Universal Dimmer
- Easy push button setup
- Trailing/Leading Edge
- Soft start feature
- Silent & flicker free
- Self Recovering Thermal Fuse
- Short Circuit & Overload Protection
Operating Voltage | 240V ac |
---|---|
Nominal Operating Frequency | 50 Hz |
Dimming Technique | Trailing & Leading edge phase control |
Compliance | BS EN 60669-2-1 |
Load Symbol | Compatible Loads |
--- | --- |
Dimmable LED lighting | 400W TE 150W LE |
240V Incandescent & Halogen lamps | 400W TE 150W LE |
Low voltage lighting with electronic | |
transformers | 400W TE 150W LE |
Multi-Gang Switch De-Rating Chart
1 Gang| 2 Gang| 3 Gang| 4 Gang| 5 Gang
400W| 340W| 280W| 220W| 160W
OPERATING INSTRUCTIONS
ON OFF & DIMMING FUNCTION
Dimmer switch is activated by pressing the dimmer shaft only, dimming function
by rotating the dimmer shaft only.
REAR PANEL PRESS BUTTON – DIMMER SETUP SEQUENCES
Setting the Minimum Level
- Whilst on, slowly adjust dimmer to your desired minimum brightness.
- Push the rear setup button 3 times within 2 seconds.
- The LEDs will step up and down in brightness once to confirm the setting has been saved.
Setting the Maximum Level
- Whilst on, slowly adjust dimmer to your desired maximum brightness.
- Push the rear setup button 5 times within 3 seconds.
- The LEDs will step up and down in brightness once to confirm the setting has been saved.
Factory reset for Min/Max brightness
Please note this factory reset will reset all the min and max brightness
settings.
- Whilst on, push the rear setup button 7 times within 5 seconds.
- The LEDs will step up and down in brightness three times to confirm that the min/max setting has been cleared.
Changing the Dimming Mode
The default mode of the dimmer is Trailing Edge, but it can be put into
Leading Edge if required. Please ensure that you know the correct mode for
your lamp.
- Whilst on, push the rear setup button 9 times within 5 seconds.
- The LEDs will step up and down in brightness twice to confirm the setting has been saved.
NOTE:
To switch back to Trailing Edge mode, just repeat the process again, the LEDs
will step up and down once to show the dimmer is back in Trailing Edge mode.
WIRING DIAGRAM – ONE WAY
WIRING DIAGRAM – TWO WAY
WARNING – PLEASE READ
RISK OF ELECTRIC SHOCK
- Hazardous voltage and electrical current may be present at the wire leads of this product even when the device is switched off.
- Lock out and tag the input circuit before accessing the wiring connections.
- This device must be installed by a qualified and experienced electrician in accordance with applicable current electrical regulation.
- To comply with all safety standards, the product must be used only for the purpose described in this instruction and must be installed in accordance with the wiring rules and regulation in the location where it is installed.
- There are no user serviceable parts inside the product.
Failure to follow these instructions can result in death or serious injury.
EQUIPMENT DAMAGE HAZARD
- Install the device according to instructions in this document.
- Pay attention to the specifications and wiring diagrams related to the installation.
- Do not use this product for any other purpose than specified in this instruction.
- The product is suitable for indoor use only.
- Apply IEC60898-1 compliant 250V~ 6A MCB as an overload protective device.
ENVIRONMENTAL PROTECTION
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or
retailer for recycling advice.
LEGAL DISCLAIMER
The installation of electrical products is inherently dangerous and can lead
to serious injury or death.
The products we sell MUST be installed by a qualified and experienced
electrician in accordance with applicable current electrical regulation. Any
advice, guidance or other information provided by Enkin on their website or
within any of our publications cannot completely anticipate your situation
and common sense must prevail. Products need to be checked prior to
installation and regularly for damage and wear and tear. Products should be
returned and not used if in any doubt of their integrity.
Electrical rated loads and limits of a given product should NEVER be exceeded
at any time. The electricity supply should always be isolated at its source
(Distribution Board) before attempting any installation or maintenance.
No advice or information, whether oral or written, obtained by you from us or
through the service, our employees, consultants and/or retailers shall create
any warranty not expressly made herein.
You agree to assume all and any risk resulting from the utilisation of
information provided by Enkin. You also expressly agree not to hold us
responsible for any damage, personal injury, death or loss resulting from your
use of our information, service or regulatory compliant products.
Enkin is a trading name of Trade Ivy. Registered in England Number: 10809945.
Copyright © 2021 All Rights Reserved. Trade Ivy Limited, Unit 3C Latham Park,
St Blazey Road, Par, PL24 2HY.
Scan QR Code for more detailed technical information on this product
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>