FRIGIDAIRE FHPC082AC1 Portable Room Air Conditioner User Guide
- June 12, 2024
- Frigidaire
Table of Contents
- INTRODUCTION
- IMPORTANT SAFETY INSTRUCTIONS
- UNIT DESCRIPTION
- ACCESSORIES INCLUDED & INSTALLATION INSTRUCTIONS
- INSTALLATION INSTRUCTIONS
- AIR CONDITIONER FEATURES
- CARE AND CLEANING
- BEFORE YOU CALL
- MAJOR APPLIANCE LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Portable Air Conditioner use & care
INTRODUCTION
Welcome to our family
Thank you for bringing Frigidaire into your home! We see your purchase as the
beginning of a long relationship together.
This manual is your resource for the use and care of your product. Please read
it before using your appliance. Keep it handy for quick reference. If
something doesn’t seem right, the troubleshooting section will help you with
common issues.
FAQs, helpful tips and videos, cleaning products, and kitchen and home
accessories are available at
www.frigidaire.com. We are here for you!
Visit our website, chat with an agent, or call us if you need help. We may be
able to help you avoid a service visit. If you do need service, we can get
that started for you. Let’s make it ofcial! Be sure to register your product.
Keep your product info here so it’s easy to find.
Model Number————————-
Serial Number—————————————————-
Purchase Date—————————–
IMPORTANT SAFETY INSTRUCTIONS
WARNING
For Your Safety
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance. Read product labels for flammability
and other warnings.
WARNIN G
Prevent Accidents
To reduce the risk of fire, electrical shock, or injury to persons when using
your air conditioner, follow basic precautions, including the following:
- Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet.
- If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first.
- Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual. Save this manual for possible future use in removing or reinstalling this unit.
WARNING
Electrical Information
The complete electrical rating of your new portable air conditioner is stated
on the serial plate. Refer to the rating when checking the electrical
requirements.
- Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
- Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
- Do not run air conditioner without outside protective cover in place. This could result in mechanical damage within the air conditioner.
- Do not use an extension cord or an adapter plug.
WARNING
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor
plug. Do not remove any prong from the power cord. Grounding type wall
receptacle
NOTE: The power supply cord with this air conditioner contains a current
detection device designed to reduce the risk of fire. Please refer to the
section ‘Operation of Current Device’ for details. In the event that the power
supply cord is damaged, it cannot be repaired. It must be replaced with a
cord from the product manufacturer.
SAFETY PRECAUTIONS
DANGER! Avoid Serious Injury or Death
- This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs.
- Do not insert or place fingers or objects into the air discharge area in the front of the unit.
- Do not start or stop the air conditioner by unplugging the power cord or turning of the power at the electrical box.
- Do not cut or damage the power cord.
- If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer.
- In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized Electrolux servicer.
- Do not operate the air conditioner with wet hands.
- Do not pull on the power cord.
- Do not drink any water that is drained from the air conditioner.
- This appliance is not intended for use by persons (including children) with reduced physical ,sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The appliance shall be installed in accordance with national wiring regulations.
SAFETY PRECAUTIONS
CAUTION! Avoid Injury or damage to the unit or other property
- Provide ventilation per installation instructions.
- Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively.
- Do not climb on or place objects on the unit.
- Do not hang objects off the unit.
- Do not place containers with liquids on the unit.
- Turn off the air conditioner at the power source when it will not be used for an extended period of time.
- Periodically check the condition of the unit’s installation accessories for any damage.
- Do not apply heavy pressure to the radiator fins of the unit.
- Operate the unit with air filter in place.
- Do not block or cover the intake grille, discharge area and outlet ports.
- Ensure that any electrical/electronic equipment is one yard away from the unit.
- Do not use or store flammable gases near the unit.
- Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
- Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
- When cleaning the unit, first make sure that the power and circuit breaker are turned off.
WARNING
FOR FLAMMABLE REFRIGERANT
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- Do not pierce or burn.
- Be aware that the refrigerants may not contain an odour.
- Compliance with national gas regulations shall be observed.
- Keep ventilation openings clear of obstruction.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance) and ignition sourcesor (for example:an operating electric heater) close to the appliance.
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification.
- Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
- DO NOT modify the length of the power cord or use an extension cord to power the unit.
- DO NOT share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
- Please follow the instruction carefully to handle, install, clear, service the air conditioner to avoid any damage or hazard. Flammable Refrigerant R32 is used within air conditioner. When maintaining or disposing the air conditioner, the refrigerant (R32 or R290) shall be recovered properly, shall not discharge to air directly.
- No any open fire or device like switch which may generate spark/arcing shall be around air conditioner to avoid causing ignition of the flammable refrigerant used. Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
- Flammable refrigerant – R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard.
- The refrigerating system should not receive maintenance, service, or repair by any person.
- Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
- Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
- Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used. The following leak detection methods are deemed acceptable for all refrigerant systems. Electronic leak detectors may be used to detect refrigerant leaks but, in the case of FLAMMABLE REFRIGERANTS, the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed, and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are also suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work.
NOTE Examples of leak detection fluids are
– bubble method,
– fluorescent method agents. If a leak is suspected, all naked flames shall be removed/extinguished. If a leakage of refrigerant is found contact local manufacter to replace unit.
READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.
Unit must be upright for one hour prior to operating.
The unit should be operated in a temperature range of 60°F – 95°F (16°C –
35°C). Performance may be reduced outside of these operating temperatures.
Operation of Current Device
The power supply cord contains a current device that senses damage to the
power cord. To test your power supply cord do the following:
- Plug in the Air Conditioner.
- The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out.
- Press the RESET button. Again you will notice a click as the button engages.
- The power supply cord is now supplying electricity to the unit. (This is also indicated by a light on the plug head).
- Do not use this device to turn the unit on or off.
- Always make sure the RESET button is pushed in for correct operation.
- The power supply cord must be replaced if it fails to reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer.
- If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one obtained from the product manufacturer.
Normal Sounds
-
High pitched Chatter
Today’s high eficiency compressors may have a high pitched chatter during the cooling cycle. -
Sound of Rushing Air At the top of the unit, you may hear the sound of rushing air being moved by the fan.
-
Gurgle/Hiss
“Gurgling or hissing” noise may be heard due to refrigerant passing through evaporator during normal operation. -
Vibration
Unit may vibrate and make noise because of uneven floor.
UNIT DESCRIPTION
Explanation of symbols displayed on the unit
| WARNING| This symbol shows that this appliance used a flammable refrigerant.
If the refrigerant is leaked and exposed to an external ignition source, there
is a risk of fire.
---|---|---
| CAUTION| This symbol shows that the operation manual should be read
carefully.
| CAUTION| This symbol shows that a service personnel should be handling this
equipment with reference to the installation manual.
| CAUTION| This symbol shows that information is available such as the
operating manual or installation manual.
Unit Description
A | Castor |
---|---|
B | Remote Control |
C | Signal Receiver |
D | Control Panel |
E | Air Outlet Grill |
F | Air Intake |
G | Air Intake |
H | Air Exhaust |
I | Air Intake |
J | Bottom Drain Outlet |
K | Power Cord |
L | Continuous Drain Outlet |
ACCESSORIES INCLUDED & INSTALLATION INSTRUCTIONS
Accessories Included
PARTS: | PARTS NAME: | QUANTITY: |
---|---|---|
Window Kit Connector A | 1 pc | |
Exhaust hose connector B | 1 pc | |
Window Kit | 1 set | |
Exhaust Hose | 1 pc | |
Screws | 4 pcs (1/2 screws) 2 pcs (3/4 screws) | |
Safety Lock | 1 pc | |
Bolts | 2 pcs | |
Foam seal A | 2 pcs | |
Foam seal B | 1 pc | |
Remote Control | 1 pc | |
Drain hose | 1 pc |
Installation Instructions
EXHAUSTING HOT AIR
In the Cool Mode the appliance must be placed close to a window or opening so
that the warm exhaust air can be ducted outside. First position unit on a flat
floor and is within the vicinity of a single circuit outlet power source. Make
sure there’s a minimum of 1.5″ clearance in the front/back of the unit, and a
minimum of 19.7″ clearance in the left/right sides of the unit.
INSTALLATION INSTRUCTIONS
- Extend either side of the hose(Fig.1A) and screw the hose to connector A(Fig.1B).
- Extend the other side of the hose and screw it to adaptor B(Fig.1C).
- Install the connector B into the unit (Fig.2).
- Affix the connector A into the window slider kit and seal.(Fig.3&4)The hose can be extended from its original length of 15″up to 59″,but it is the best to keep the length to minimum required. Also make sure that the hose does not have any sharp bends or sags.(Fig.5)
Installation in a double-hung sash window
-
Cut the foam seals A(adhesive type) to the proper lengths and attach them to the window and stool.(Fig.6)
-
Open the window sash and place the window slider kit on the window stool (Fig.7). Attach the window slider kit to the window stool. Adjust the length of the window slider kit according to the width of window. Screw down the two screws on the window slider kit. See Fig.7. Cut the adjustable window slider kit if the width of window is less than 26.6 inches(Fig.8).
-
Close the window sash securely against the window slider kit.(Fig.9)
-
Drive two 1/2″ screws to secure the window slider kit to the window sash.(Fig.9)
-
Secure the window slider kit to the window stool(Fig.9):
A: For wooden window: Use 3/4″ screws for securing.
B: For Vinyl-Clad windows: Use 1/2″ hex head cap screws for securing. -
To secure lower sash in place, attach right angle sash lock with 1/2″ (12.7mm) screw as shown(Fig.10).
NOTE: It is difficult to lock the windows with the sash lock for Vinyl-Clad windows, so you can use lock by window itself. -
Cut the foam seal B to an appropriate length and seal the open gap between the top window sash and outer window sash, as shown in Fig.11.
Installation in a sliding sash window
-
Cut the foam seals A(adhesive type) to the proper lengths and attach them to the window frame. See Fig.12.
-
Open the window sash and place the window slider kit on the window stool (Fig.13). Attach the window slider kit to the window stool. Adjust the length of the window slider kit according to the height of window.
Screw down the two screws on the window slider kit. See Fig.13. Cut the adjustable window slider kit if the height of window is less than 26.6 inches(Fig.8). -
Close the window sash securely against the window slider kit.(Fig.14)
-
Drive two 1/2″ screws to secure the window slider kit to the window sash.(Fig.14)
-
Drive two 3/4″ screws to secure the window slider kit to the window stool.(Fig.14)
-
Cut the foam seal B to an appropriate length and seal the open gap between the sliding sash and outer window sash, as shown in Fig.15.
-
To secure sliding sash in place, attach right angle sash lock with 1/2″ (12.7mm) screw as shown(Fig.16).
AIR CONDITIONER FEATURES
Control Panel
A | Filter Reset |
---|---|
B | Display Temperature/Timer |
C | Sleep indicator |
D | Timer indicator |
E | Power on/o |
F | Fan Speed |
G | Adjust Temperature or Timer |
H | Mode Selection |
OPERATING INSTRUCTION
Cool mode
Press the “mode” button until the Cool mode indicator lights.
Press the “fan speed” button to choose the fan speed according to the
illumination of the fan speed indicator.
You can choose the “hi”, “low”, or “auto” fan speed setting.
Press the “ ” or “ ”button to choose the temperature you want.
Dry mode
Press the “mode” button until the Dry mode indicator lights. In this mode, the
“ ” or “ ” button is disabled and the screen displays the room temperature.
The unit will continuously drain moisture from the room.
Note: In this mode, the fan speed will be set as “low” automatically,
which cannot be changed.
In this mode, condensate drainage are required, refer to the “Drainage
Instructions” on Page 18 for more instructions to drain the excess condensate.
OPERATING INSTRUCTIONS
Fan mode
Press the “mode” button until the Fan mode indicator lights.
In this mode, you can select fan speed “hi” or “low”.
The screen displays room temperature.
Note: In this mode, the air exhaust hose does not need to be connected.
Auto mode
Press the “mode” button until the Auto mode indicator lights.
Press the “ ” or “ ” button to choose the temperature you want. The screen
will display the setting temperature.
In this mode, the unit will automatically select cooling, heating(not
applicable for cooling only models), or fan only operation depending on what
temperature you have selected and the room temperature. The air conditioner
will control room temperature automatically around the temperature point set
by you.
Note: In this mode, fan speed cannot be selected.
Filter reset
This feature is a reminder to clean the Air Filter (See Care and Cleaning) for
more eFFIcient operation.
The filter indicator will illuminate after 250 hours of fan operation. Press
the “filter reset” button, to reset after cleaning the filter.
°F/°C function
Press the “ ” and “ ”button the same time for more than 3 seconds to switch
between degree Fahrenheit and degrees Celsius.
Note: Under Dry/Fan mode, you can not select °F/°C.
Remote Control
A | Timer Button |
---|---|
B | Mode Button |
C | Temp/Timer Setting Button |
D | Remote Control Screen |
E | on·off Button |
F | Fan Speed Button* |
G | Swing Button** |
H | Sleep Button |
Note:
*By pressing the “speed” button, the remote control display various fan speed settings in a sequence of “auto”, “high”, “mid” and “low”. Please note that this particular model does not have a “mid” setting, as it is reserved for other models.
The “swing” feature is reserved for other models.
Battery Installation and Important Instructions**
Remove the cover at the back of the remote control. Insert the provided
batteries correctly(see the instructions inside the battery compartment).
Close up the cover.
To replace the old batteries(which have been used up) with two new R03 “AAA”
1.5V batteries, repeat the steps above. If the remote control unit is replaced
or discarded, the batteries must be removed and disposed of in accordance with
local legislation as they do harm to the environment.
Do not mix old and new batteries.
Do not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium)
batteries. Do not dispose of batteries in fire. Batteries may explode or leak.
If the remote control is not used for a long time, remove the batteries from
the remote control. The remote control must be handled with extreme care. Do
not drop it or expose it to direct sunlight or sources of heat. Point the
remote control at the location of the signal receiver. The remote control must
be no more than 16 ft(5 meters) away from the unit (without obstacles between
the remote control and the unit).
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. How to Use the Remote Control Turning the unit on Plug in the unit, then press the “on·of” button (when turned on, the unit will operate as the last setting before shutdown. To switch the unit of, press “on·of” button again, then remove the plug. Do NOT switch the unit of by removing the plug. Always switch the unit of by pressing the “on·of” button and wait for few minutes before removing the plug. Cool mode Press the “mode” button until the left side of LCD screen displays “cool”. Press the “speed” button to choose the fan speed “auto”, “high” and “low”. Press the “ ” and “ ” button to choose the temperature you want.
Dry mode
Press the “mode” button until the left side of LCD screen displays “dry”.
In this mode, the “ ” or “ ” button is disabled and the screen will remain
blank. The unit will continuously drain moisture from the room.
Note:
In this mode, the fan speed will be set as “low” automatically, which cannot
be changed.
In this mode, condensate drainage are required, refer to the “Drainage
Instructions” on Page 18 for more instructions to drain the excess condensate.
Fan mode
Press the “mode” button until the left side of LCD screen displays “fan”. In
this mode, you can select fan speed “high”, “low” by pressing the Fan speed
button and referring to the diagram.
Note: In this mode, the air exhaust hose does not need to be connected.
Auto mode
Press the “mode” button until the left side of LCD screen displays “auto”.
Press the “ ” and “ ” button to choose the temperature you want. In this mode,
the unit will automatically select cooling, heating(not applicable for cooling
only models), or fan only operation depending on what temperature you have
selected and the room temperature. The air conditioner will control room
temperature automatically round the temperature point set by you.
Note: In this mode, fan speed cannot be selected.
Sleep mode
When the unit is in Cool, Heat or Auto mode, you can press the “sleep” button
to make the unit run in Sleep mode. In this mode, the fan speed will be set as
“Auto” automatically, which cannot be changed.
In Cool/Heat mode the selected temperature will increase/decrease by 2 °F 30
minutes after the mode is selected. The temperature will then
increase/decrease by another 2 °F after an additional 30 minutes.
This new temperature will be maintained for 7 hours before it returns to the
originally selected temperature. This ends the “Sleep” mode and the unit will
continue to operate as originally programmed.
The “Sleep” mode program can be cancelled at any time during operation by
pressing the “Sleep”, “mode”, “fan speed” or “on·off” button.
Note: In Fan or Dry mode, Sleep mode cannot be set.
°F/°C function
Press the “ ” and “ ”button the same time for more than 3 seconds to switch
between degree Fahrenheit and degrees Celsius.
Note: Under Dry/Fan mode, you can not select °F/°C.
Timer mode
How to delay startup
Plug in the unit, so the unit turns to standby.
Press the “timer” button, when the unit is of. The screen will display “timer”
and “h”, and the “on” will flashing. Tap or hold the UP arrow ” ” or the DOWN
arrow ” ” to change delay start timer at 0.5 hour increments up to 10 hours,
then at 1 hour increments up to 24 hours. After 3 seconds, the timer function
is enabled, then “on” will stop flashing, the display will show the temperature
back and the control will count down the time remaining until startup. The
unit will start up in the mode as previously set.
To cancel the setting, press the “timer” button again. You can also cancel the
setting by pressingthe “on·of” button.
How to delay shutdown
You can delay shutdown when the unit is on.
Press the “timer” button, when the unit is on. The screen will display
“timer”and “h”, and the “of ” will flashing. Tap or hold the UP arrow “ ” or
the DOWN arrow “ ” to change delay shutdown timer at 0.5 hour increments up to
10 hours, then at 1 hour increments up to 24 hours. After 3 seconds, the timer
function is enabled, then “off ” will stop flashing, the display will show the
temperature back and the control will count down the time remaining until
shutdown. To cancel the setting, press the “timer” button again. You can also
cancel the setting by pressingthe “on·of” button.
Fault Code
If the screen on the unit displays “AS”, the room temperature sensor has
failed. Contact your Authorized Frigidaire Service Center.
If the display reads “E4”, the communication between display PCB and main
control PCB is faulty. Contact your Authorized Frigidaire Service Center.
If the screen on the unit displays “ES”, the pipe temperature sensor has
failed. Contact your Authorized Frigidaire Service Center.
Emptying the condensate residue inside the unit for the P1 message or during
winter storage. Refer to the “Drainage Instructions” on Page 18 for more
instructions to drain the successive condensate. If error repeats, contact
your Authorized Frigidaire Service Center.
Drainage Instructions
Continuous Drainage
During the Dry mode, you will need a garden hose (sold separately) to drain
the condensate from the unit. Follow the steps below:
- Unscrew the drain cap of continuous drain outlet and remove the rubber plug(Fig.20).
- Connect one end of the garden hose (sold separately) to the drain outlet then lead the other end into a drain that is lower than the unit(Fig.21). NOTE:
- Condensate may flow out after removing the drain cap, if the unit is running in Cool or Auto mode. When you want to remove the garden hose, prepare a drip tray (not supplied) to collect the condensate from the drain outlet.
- Please be sure that the height of the drain and section of the drain hose should not be higher than that of the drain outlet, or the continous drainage may not work properly.
- During Cool or Auto mode, it is recommended to disable continuous drainage by replacing the drain cap to the drain outlet, to reach the maximum performance.
Emptying the condensate residue inside the unit during winter storage.
Put a drip tray (not supplied) under the continuous drain outlet, then unscrew
the drain cap to allow the condensate to flow into the drip tray. Replace the
drain cap to the continuous drain outlet when no condensate flows out. Put the
drip tray under the bottom drain outlet, then remove the rubber stopper from
the drain outlet, to allow the condensate to flow into the drip tray. If your
drip tray can’t hold all the condensate, a number of fills will be needed.
Replace the drain cap to the bottom drain outlet when no condensate flows out.
Note: To ensure all condensate residue has been removed, tilt the unit by lifting it slightly upwards from the front until no more condensate comes out from the drain outlet.
CARE AND CLEANING
Cleaning
Clean your air conditioner occasionally to keep it looking new. Be sure to
unplug the unit before cleaning to prevent shock or fire hazards.
CLEANING THE UNIT
The cabinet and front may be dusted with an oil-free cloth or washed with a
cloth dampened in a solution of warm water and mild liquid dishwashing
detergent. Never use harsh cleaners, wax or polish on the cabinet front. Be
sure to wring excess water from the cloth before wiping around the controls.
Excess water in or around the controls may cause damage to the air
conditioner.
CLEANING THE FILTERS
To keep your air conditioner working efficiently, you should clean the filters
every week of operation.
This unit has two filters, they are filter A and B. Grasp the upper panel tab
and take off the filter A which behind the grill of the back panel. Then pull
out the side filter B from the right side of the back of the unit (Fig.25).
Wash the filter using liquid dishwashing detergent and warm water. Rinse filter
thoroughly. Gently shake excess water from the filter. Be sure filter is
thoroughly dry before replacing. Or, instead of washing you may vacuum the
filter clean. Replace the filter after the filter is dry.
If the air conditioner will not be used for an extended period of time:
- Drain the water collection tank completely and leave the bottom drain cap and rubber plug long time enough to allow any residual water to drain out. Once the tank is completely drained and no more water flows out, reinstall the rubber plug and cap.
- Remove and clean the filter, allow it to dry completely, then reinstall it.
- Remove the batteries from the remote control. Winter Storage
- Store the air conditioner in a cool, dry location, away from direct sunlight, extreme temperature, and excessive dust.
Before using the air conditioner again:
- Make sure the filter and drain cap are in place.
- Check the cord to make sure it is in good condition, without cracks or damage.
- Place new batteries in the remote control.
- Install the air conditioner as described in the Installation Instructions.
BEFORE YOU CALL
Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.
OCCURRENCE | SOLUTION |
---|---|
Air conditioner will not operate. | • Wall plug disconnected. Push plug firmly |
into wall outlet.
• Plug Current Device Tripped. Press the RESET button.
• House fuse blown or circuit breaker tripped. Replace fuse with time delay
type or reset circuit breaker.
• Control is OFF. Turn Control ON and set to desired setting.
• P1 appears in the display window. Drain water as described in Drainage
Section.
• Room Temperature lower than the set temperature (Cool Mode). Reset the
temperature.
Air from unit does not feel cold enough.c| • Room temperature below 60°F
(16°C). Cooling may not occur until room temperature rises above 60°F (16°C).
• Reset to a lower temperature.
• Compressor shut-off by changing modes. Wait approximately 4 minutes and
listen for compressor to restart when set in the COOL mode.
Air conditioner cooling, but room is too warm – ice
forming on cooling coil behind decorative front| • Outdoor temperature below
60 F (16 C). To defrost the coil, set FAN ONLY mode.
• Air filter may be dirty. Clean filter. Refer to Care and Cleaning section.
To defrost, set to FAN ONLY mode.
• Temperature is set too low for night-time cooling. To defrost the coil,
set to FAN ONLY mode. Then, set temperature to a higher setting.
• Exhaust duct not connected or blocked. See EXHAUSTING HOT AIR Section.
Air conditioner cooling, but room is too warm – NO ice forming on cooling coil
behind
decorative front.| • Dirty air filter – air restricted. Clean air filter.
Refer to Care and Cleaning section.
• Temperature is set too high. Set temperature to a lower setting.
• Air directional louvers positioned improperly. Position louvers for better
air distribution.
• Front of unit is blocked by drapes, blinds, furniture, etc. – restricts
air distribution. Clear blockage in front of unit.
• Doors, windows, registers, etc. open – cool air escapes. Close doors,
windows, registers, etc.
• Unit recently turned on in hot room. Allow additional time to remove
“stored heat” from walls, ceiling, floor and furniture.
Air conditioner turns on and of rapidly.| • Dirty air filter – air
restricted. Clean air filter.
• Outside temperature extremely hot. Set FAN speed to a faster setting to
bring air through cooling coils more frequently.
Noise when unit is cooling.| • Air movement sound. This is normal. If too
loud, set to lower FAN setting.
• Vibration from uneven floor. Move or support appliance correctly on even
surface.
Room too cold.| • Set temperature too low. Increase set temperature.
Room too hot.| • Set temperature too high. Lower setting.
If These Solutions Fail, Call
1-800-944-9044(US)/1-800-265-8352(Canada)
For Frigidaire Service.
MAJOR APPLIANCE LIMITED WARRANTY
Your appliance is covered by a limited one-year warranty for functional
repairs only. For one year from your original date of purchase, Electrolux
will pay all costs for repairing or replacing any parts of this appliance that
prove to be defective in materials or workmanship when such appliance is
installed, used and maintained in accordance with the provided instructions.
After one year from your original date of purchase, the consumer will be
responsible for diagnostic, labor and parts costs as well as any removal,
transportation and reinstallation expenses which are incurred during service
on components.
Exclusions
This warranty does not cover the following:
- Products with original serial numbers that have been removed, altered or cannot be readily determined.
- Product that has been transferred from its original owner to another party or removed outside the USA or Canada.
- Rust on the interior or exterior of the unit.
- Products purchased “as-is” are not covered by this warranty.
- Food loss due to any refrigerator or freezer failures.
- Products used in a commercial setting.
- Service calls which do not involve malfunction or defects in materials or workmanship, or for appliances not in ordinary household use or used other than in accordance with the provided instructions.
- Service calls to correct the installation of your appliance or to instruct you how to use your appliance.
- Expenses for making the appliance accessible for servicing, such as removal of trim, cupboards, shelves, etc., which are not a part of the appliance when it is shipped from the factory.
- Service calls to repair or replace appliance light bulbs, air filters, water filters, other consumables, or knobs, handles, or other cosmetic parts.
- Surcharges including, but not limited to, any after hour, weekend, or holiday service calls, tolls, ferry trip charges, or mileage expense for service calls to remote areas, including the state of Alaska.
- Damages to the finish of appliance or home incurred during installation, including but not limited to floors, cabinets, walls, etc.
- Damages caused by: services performed by unauthorized service companies; use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies; or external causes such as abuse, misuse, inadequate power supply, accidents, fires, or acts of God.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE
PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED
WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY
LAW, BUT NOT LESS THAN ONE YEAR. ELECTROLUX SHALL NOT BE LIABLE FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL
EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY
IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE
DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT
APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY
ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
If You Need Service
Keep your receipt, delivery slip, or some other appropriate payment record to
establish the warranty period should service be required. If service is
performed, it is in your best interest to obtain and keep all receipts.
Service under this warranty must be obtained by contacting Electrolux at the
addresses or phone numbers below. This limited warranty only applies in the
USA and Canada. In the USA, your appliance is warranted by Electrolux Major
Appliances North America, a division of Electrolux Home Products, Inc. In
Canada, your appliance is warranted by Electrolux Canada Corp. Electrolux
authorizes no person to change or add to any obligations under this warranty.
Obligations for service and parts under this warranty must be performed by
Electrolux or an authorized service company. Product features or specifications
as described or illustrated are subject to change without notice.
USA
1.800.944.9044
Electrolux Major Appliances
10200 David Taylor Drive
Charlotte, NC 28262
Canada
1.800.265.8352
Electrolux Canada Corp.
5855 Terry Fox Way
Mississauga, Ontario, Canada
L5V 3E4
Our home is your home.
Visit us if you need help with any of these things:
owner support
accessories
service
registration
(See your registration card for more information.)
Frigidaire.com
1-800-944-9044
Frigidaire.com
1-800-265-8352
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>