ENKIN IDM250 250W Universal In Line LED Dimmer Module User Guide

June 16, 2024
ENKIN

ENKIN logo IDM250
250W Universal In-Line LED Dimmer Module

IDM250 250W Universal In Line LED Dimmer Module

  • Easy push button setup
  • Trailing/Leading Edge
  • No Neutral required
  • On, Off & Dimming funtion controlled via connected Retractive Switch(s)
  • Soft start feature
  • Small form factor, will fit into an achitrave back box
  • Silent & flicker free
  • Self Recovering Thermal Fuse
  • Short Circuit & Overload Protection
Operating Voltage 240V ac
Nominal Operating Frequency 50 Hz
Dimming Technique Trailing & leading edge phase control
Compliance BS EN 60669-2-1
Load Symbol Compatible Loads
--- ---
Dimmable LED lighting 250W TE
100W LE 2W
240V Incandescent
& Halogen lamps 250W TE
100W LE 2W
Low voltage lighting with
electronic transformers 250W TE
100W LE 2W

Multi-Gang Switch De-Rating Chart

1 Gang| 2 Gang| 3 Gang| 4 Gang| 5 Gang
250W| 212W| 175W| 137W| 100W

SETUP INSTRUCTIONS

On/Off and dimming is achieved with a connected Retractive Switch, or multiple (parallel) Retractive Switches, please refer to example circuit diagrams on the other side of this document for details.
A fast click of the Retractive Switch will turn the lamp (or Load) on and off, holding the switch will alternately dim the lamp up or down, release the switch when desired lamp brightness has been achieved.
The minimum/maximum level and dimming mode can be manually adjusted by following the procedures below.
SETTING THE MINIMUM LEVEL

  1. Whilst on, adjust dimmer to your desired minimum brightness.
  2. Push the setup button 3 times within 2 seconds.
  3. The LEDs will step up and down in brightness once to confirm the setting has been saved.

SETTING THE MAXIMUM LEVEL

  1. Whilst on, adjust dimmer to your desired maximum brightness.
  2. Push the setup button 5 times within 3 seconds.
  3. The LEDs will step up and down in brightness once to confirm the setting has been saved.

FACTORY RESET FOR MIN/MAX BRIGHTNESS
Please note this factory reset will reset all the min and max brightness settings.

  1. Whilst on, push the rear setup button 7 times within 5 seconds.
  2. The LEDs will step up and down in brightness three times to confirm that the min/max setting has been cleared.

CHANGING THE DIMMING MODE
The default mode of the dimmer is Trailing Edge, but it can be put into Leading Edge if required. Please ensure that you know the correct mode for your lamp.

  1. Whilst on, push the setup button 9 times within 5 seconds.
  2. The LEDs will step up and down in brightness twice to confirm the setting has been changed to Leading Edge mode.

NOTE:
To switch back to Trailing Edge mode, just repeat the process again, the LEDs will step up and down once to show the dimmer is back in Trailing Edge mode.
WIRING DIAGRAM
Single Retractive SwitchENKIN IDM250 250W Universal In Line LED Dimmer
Module - parts WIRING DIAGRAM
Multiple Retractive SwitchesENKIN IDM250 250W Universal In Line LED Dimmer
Module - parts1

https://enkin.com/250w-led-inline-dimmer-module-idm250/

Scan QR Code for more detailed technical information on this product
www.enkin.com WARNING – PLEASE READ
RISK OF ELECTRIC SHOCK

  • Hazardous voltage and electrical current may be present at the wire leads of this product even when the device is switched off.
  • Lock out and tag the input circuit before accessing the wiring connections.
  • This device must be installed by a qualified and experienced electrician in accordance with applicable current electrical regulation.
  • To comply with all safety standards, the product must be used only for the purpose described in this instruction and must be installed in accordance with the wiring rules and regulation in the location where it is installed.
  • There are no user serviceable parts inside the product.
    Failure to follow these instructions can result in death or serious injury.

EQUIPMENT DAMAGE HAZARD

  • Install the device according to instructions in this document.
  • Pay attention to the specifications and wiring diagrams related to the installation.
  • Do not use this product for any other purpose than specified in this instruction.
  • The product is suitable for indoor use only.
  • Apply IEC60898-1 compliant 250V~ 6A MCB as an overload protective device.

ENVIRONMENTAL PROTECTION
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.

LEGAL DISCLAIMER

The installation of electrical products is inherently dangerous and can lead to serious injury or death. The products we sell MUST be installed by a qualified and experienced electrician in accordance with applicable current electrical regulation. Any advice, guidance or other information provided by Enkin on their website or within any of our publications cannot completely anticipate your situation and common sense must prevail. Products need to be checked prior to installation and regularly for damage and wear
and tear. Products should be returned and not used if in any doubt of their integrity.
Electrical rated loads and limits of a given product should NEVER be exceeded at any time. The electricity supply should always be isolated at its source (Distribution Board) before attempting any installation or maintenance.
No advice or information, whether oral or written, obtained by you from us or through the service, our employees, consultants and/or retailers shall create any warranty not expressly made herein.
You agree to assume all and any risk resulting from the utilisation of information provided by Enkin. You also expressly agree not to hold us responsible for any damage, personal injury, death or loss resulting from your use of our information, service or regulatory compliant products.

ENKIN logoEnkin is a trading name of Trade Ivy. Registered in England Number: 10809945. Copyright © 2021
All Rights Reserved. Trade Ivy Limited, Unit 3C Latham Park, St Blazey Road, Par, PL24 2HY.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals