HOERMANN BEA LZR-H100 Laser Scanner Protection Opening Barrier Arms Instruction Manual
- June 16, 2024
- HOERMANN
Table of Contents
HOERMANN BEA LZR-H100 Laser Scanner Protection Opening Barrier Arms
Product Information
Specifications
- Model: BEA LZR-H100
- Barrier Model: SH 100
- Power Supply: 230 V AC / 24 V DC
- Operating Voltage: 24 V DC
- Signal Voltage: 0 V / 24 V
FAQ
Q: What are the color codes for the wiring?
The color codes for the wiring are as follows:
- Red: Safety field
- Pink: A1
- Blue: A2
- Violet: A1.1
- White: A2.1
- Yellow: Ext. Impuls
Product Usage Instructions
Step 1: Mounting the Photocell BEA LZR-H100 on Barrier SH 100
Follow these steps to mount the photocell on the barrier:
- Identify the components: LZR H100, SH 100, A1, A1.1, A2, A2.1
- Position the LZR H100 on the barrier SH 100
- Secure the LZR H100 using the provided screws (2 x TX10)
- Attach A1 and A1.1 to the safety field
- Attach A2 and A2.1 to the barrier
Step 2: Electrical Connection
Connect the photocell to the power supply following these steps:
- Identify the power supply requirements: 230 V AC / 24 V DC
- Connect the power supply to the photocell
- Ensure the correct voltage is selected (24 V DC)
- Connect the signal voltage (0 V / 24 V) as required
Step 3: Adjusting the Photocell
Follow these steps to adjust the photocell:
- Ensure the barrier SH 100 is in the desired position
- Adjust the photocell LZR H100 to align with the barrier
- Secure the photocell in place using the provided screws (3 x TX10)
What In The Box
Overview
Warning
Information
Installation Instructions
- GN: Green
- RD: Red
- PK: Pink
- BN: Brown
- BU: Blue
- VT: Violet
- WH: White
- YE: Yellow
Using Instructions
- Opening field
- Safety field
HÖRMANN KG Verkaufsgesellschaft
- Upheider Weg 94 – 98
- 33803 Steinhagen Deutschland
HA30F104-A / 4838886
Read User Manual Online (PDF format)