HOERMANN HET-E2 SL Receiver Instruction Manual
- October 30, 2023
- HOERMANN
Table of Contents
- HET-E2 SL Receiver Instruction Manual
- About these instructions
- Safety instructions
- Scope of delivery
- Description of the receiver
- Fitting
- Connection
- Functions
- Teaching in a radio code
- Operation
- Feedback on the position of the perimeter protection system
- Reset
- Disposal
- Technical data
- EU and UK Declaration of Conformity
- Documents / Resources
HET-E2 SL Receiver
Instruction Manual
Fitting and Operating Instructions
Receiver HET-E2 SL BiSecur
HET-E2 SL Receiver Instruction Manual
Dissemination as well as duplication of this document and the use and
communication of its content are prohibited unless explicitly permitted.
Noncompliance will result in damage compensation obligations.
All rights reserved in the event of patent, utility model or design model
registration. Subject to changes.
Dear Customer, we would like to thank you for choosing a quality product from our company.
About these instructions
Read through all of the instructions carefully, as they contain important
information about the product. Pay attention to and follow the instructions
provided, particularly the safety instructions and warnings.
Further information about handling radio components can be found on the
Internet.
Please keep these instructions in a safe place and make sure that they are
available to all users at all times.
Safety instructions
2 .1 Intended use
The HET-E2 SL BiSecur receiver is a bidirectional receiver for the actuation
of operators and controls. It has two channels and is operated via the BiSecur
radio. The receiver has two volt-free relay outputs and a 3-pin input for
volt-free limit switch reporting for lowered and raised bollards.
Other types of application are prohibited. The manufacturer is not liable for
damage caused by improper use or incorrect operation.
2 .2 Safety instructions for operating the receiver
CAUTION
Danger of injury from unintentional raising/lowering
▶ See warning in section 8
ATTENTION
Functional impairment caused by environmental conditions Non-compliance with
these instructions can impair function!
Protect the receiver from the following conditions:
- Direct sunlight (permissible ambient temperature: – 20 °C to + 60 °C)
- Moisture
- Dust
NOTES:
- After programming or extending the radio system, check the functions.
- Only use original components when putting the radio system into service or extending it.
- Local conditions may affect the range of the radio system.
- When used at the same time, GSM 900 mobile phones can affect the range.
Scope of delivery
- Receiver HET-E2 SL BiSecur
- External antenna
- Fitting and fixing material
- Operating Instructions
Description of the receiver
- Receiver
- Connecting terminal for 12 – 24 V DC power supply
- Connecting terminal of the relay outputs
- 3-pin connection screw terminal, plug-in type
- Connection socket for external antenna
- Programming button P (P button)
- LED, blue (BU), programming
- Housing (optional)
4 .1 LED display
Blue (BU)
State | Function |
---|---|
Illuminates once briefly | A valid radio code was discovered for channel 1 |
Illuminates 2 times briefly | A valid radio code was discovered for channel 2 |
Flashes once | Receiver is in the learn mode for channel 1 |
Flashes 2 × | Receiver is in the learn mode for channel 2 |
Flashes quickly after slow flashing | A valid radio code was detected during |
the teach-in procedure
Flashes slowly for 5 seconds,
Flashes quickly for 2 seconds| Device reset is being performed or completed
Off| Operation mode
4 .2 Button
P button | Selection of the radio channel/relay |
---|
Fitting
NOTE:
By selecting an appropriate fitting location, the range can be optimised. The
best orientation to achieve an optimum range must be established by trial and
error.
Connection
Terminal E2 | Normally open contact | Limit switch reporting connection lowered |
---|---|---|
Terminal GND | Shared contact | 0 V reference potential |
Terminal E1 | Normally open contact | Limit switch reporting connection raised |
NOTE:
The maximum approved cable length is 30 m. The input terminal cable cross-
section may be 0.08 – 1.0 mm²; all other terminals 0.12 – 1.5 mm².
The starting sequence begins when the receiver is supplied with 24 V DC
voltage.
The blue LED remains lit, depending on the number of already taught-in radio
codes, ntil the communication link is established. No functions are permitted
at this time.
The receiver is ready for operation as soon as the blue LED goes out.
NOTE:
After a power failure, the receiver operates in the same way when the power
returns.
Functions
The HET-E2 SL BiSecur receiver has two volt-free relay outputs and a 3-pin
input for two volt-free normally open contacts. The relay outputs permit the
choosing directions raise and lower. The raised and lowered limit switch
reporting is connected at the input.
Relay output 1 = press and hold (impulse 0.5 s)
Relay output 2 = press and hold (impulse 0.5 s)
7 .1 0 .5-second impulse function
When a transmission impulse is received, the relay is activated for 0.5
seconds and then deactivated.
7 .2 Function of the P button
The P button is used to select the radio channel/relay on which a radio code
is to be taught in.
Teaching in a radio code
CAUTION
Danger of injury from unintentional raising / lowering Unintended movements
may occur while teaching in the radio system.
▶Make sure that no persons or objects are in the perimeter protection system’s area of travel when teaching in the radio system.
A maximum of 100 radio codes can be taught in on the receiver. They can be
distributed over the existing channels as desired. If the same radio code is
taught in on two different channels, it will be deleted on the first taught-in
channel. If more than 100 radio codes are taught in, the first ones to be
taught in will be deleted.
In learn mode, the channels of the receiver can be switched by pushing the P
button, as long as no radio code has been recognised.
To activate/switch a channel:
▶Press the P button once to activate channel 1.
▶ Press the P button 2 times to activate channel 2.
To abort the learn mode:
▶ Press the P button 3 times or wait for the timeout.
Timeout
If no valid radio code is detected within 25 seconds, the receiver
automatically returns to the operation mode.
8 .1 Teaching in a radio code
-
Press the P button to activate the desired channel.
– The blue LED flashes once for channel 1
– The blue LED flashes twice for channel 2 -
Switch the hand transmitter whose radio code is to be inherited to Inheriting /Transmitting mode.
If a valid radio code is detected, the LED flashes quickly in blue and then goes out.
The receiver is in the operation mode.
Operation
In the operation mode, the receiver signals the recognition of a valid radio
code by illuminating the blue LED.
NOTE:
If the radio code for the taught-in hand transmitter button was copied from
another hand transmitter, the hand transmitter button must be pressed a second
time during initial start-up.
A valid radio code channel 1 is discovered = The LED is illuminated briefly 1
time
A valid radio code channel 2 is discovered = The LED is illuminated briefly
twice
Feedback on the position of the perimeter protection system
The HS 5 BiSecur hand transmitter only receives feedback if the bollard raised and bollard lowered limit switch reporting is connected to the 3-pin input (E1/GND/E2).
| HS 5 BiSecur| LED
---|---|---
Bollard raised| Position: raised| Green
Bollard lowered| Position: lowered| Red
Bollard in motion| Position: not lowered| Green
Position unknown/error| Position: not lowered| Red
No feedback| Communication error/beyond range| Orange
10 .1 No feedback
After the command for manual position query
There is a communication error or the receiver is out of range if the HET-E2
SL BiSecur receiver does not receive feedback from the control within 5
seconds after the command.
The HS 5 BiSecur hand transmitter does not subsequently receive any feedback
from the receiver and the LED on the hand transmitter flashes orange quickly 4
times.
After the command for automatic feedback on the position
The function for automatic feedback on the position is not supported by this
receiver.
Reset
All radio codes are deleted by the following steps:
-
Press and hold the P button.
– The LED slowly flashes in blue for 5 seconds.
– The LED flashes rapidly in blue for 2 seconds. -
Release the P button.
All radio codes have been deleted .
NOTE:
If the P button is released prematurely, the device reset will be aborted and
the radio codes are not deleted.
Disposal
| Dispose of the packaging sorted by materials.
---|---
****| Electrical and electronic devices must be returned to the appropriate
recycling facilities.
| Dispose of the batteries separately. Each consumer is legally required to
leave batteries with a collection point in their community, their district, or
with a trader.
Technical data
HET-E2 SL BiSecur receiver
Model| HET-E2-868-BS-SL
Frequency| 868 MHz
Transmitting power (EIRP)| max. 20 mW
Power supply| 24 V DC
Perm. ambient temperature| −20 °C to +60 °C
max. humidity| 93 % non-condensing
Protection category| IP 65
Relay capacity| max. 2,5 A / 30 V DC
Dimensions (W × H × D)| 150 × 70 × 55 mm
EU and UK Declaration of Conformity
Hörmann KG Verkaufsgesellschaft and Hörmann UK Ltd. herewith declares that the
radio equipment type HET-E2 SL BiSecur receiver complies with the EU Directive
2014/53/EU and the UK Regulations 2017 No. 1206.
The complete text of the EU Declaration of Conformity and of the UK
Declaration of Conformity can be found on the following website:
HET-E2 SL BiSecur
Hörmann KG Verkaufsgesellschaft
Upheider Weg 94-98
33803 Steinhagen
Deutschland
4549982 B1
Documents / Resources
|
HOERMANN HET-E2 SL
Receiver
[pdf] Instruction Manual
HET-E2 SL Receiver, HET-E2 SL, Receiver
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>