Specifications:
- Model Number: WNACB46
- Compatibility: Must be used with a Netatmo gateway in conjunction with a WNAL10 or WNAL50
- Regulatory Compliance: FCC Part 15, Industry Canada license-exempt RSS standards
- FCC ID: 2AU5D-WACB4
- IC: 25764-WACB4
- Minimum Separation Distance: 20 cm from the transmitter’s radiating structure(s) to the user or nearby persons
Product Usage Instructions
Installation:
This device is designed for indoor installation only. It can be installed in
any standard electrical wall box of any gang size.
Before starting the installation process, always disconnect power at the service panel to prevent severe shock or electrocution.
Note: Failure to connect the ground wire will result in an unsafe installation that could lead to personal injury.
Wiring:
If necessary, cut wires and strip insulation using the stripping guide on the
back of the switch.
Note: Failure to connect the ground wire will result in an unsafe installation that could lead to personal injury.
Connect the frame ground wire to the bare ground wire in the electrical box. Fold the ground wires into the back of the box.
Mounting:
Mount the frame to the wall box using the screws provided.
Tighten the screws just enough to hold the frame in place. Do not over-
tighten.
FAQ:
Q: What is the model number of this device?
A: The model number of this device is WNACB46.
Q: Can this device be used without a Netatmo gateway?
A: No, this device must be used with a Netatmo gateway in conjunction with
a WNAL10 or WNAL50.
Q: What are the regulatory compliance standards for this device?
A: This device complies with FCC Part 15 and Industry Canada license-exempt
RSS standards.
Q: What is the minimum separation distance required for this device?
A: The minimum separation distance between the transmitter’s radiating
structure(s) and the user or nearby persons is 20 cm.
Catalog Number(s)
This device must be used with a Netatmo gateway in conjunction with a WNAL10
or WNAL50.
WNACB46
Smart Remote Scene Controller with Netatmo
REGULATORY INFORMATION
FCC NOTICE: This device complies with Part 15 of the FCC rules. Operation
is subject to the following two conditions:(1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesirable operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is
no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the transmitter’s radiating structure(s) and the body of the user or nearby persons.
NOTE: Any changes or modifications to this device that are not expressly approved by the manufacturer will void the warranty and the user’s authority to operate the equipment.
Contains FCC ID: 2AU5D-WACB4
IC NOTICE: This device complies with Industry Canada license-exempt RSS
standards. Operation is subject to
the following two conditions: (1) this device may not cause interference; and
(2) this device must accept any interference, including interference that may
cause undesired operation of the device.
RF EXPOSURE STATEMENT: This equipment meets the SAR evaluation limits
given in RSS-102 Issue 5 requirements at the minimum separation distance of 20
cm to the human body. Note: Any changes or modifications to this device that
are not expressly approved by the manufacturer, will void the warranty and the
user’s authority to operate the equipment.
IC: 25764-WACB4
HVIN: WNACB46
For more information and helpful how-to videos, visit www.adornemyhome.com/install.
INSTALLATION INSTRUCTIONS
Please read these instructions completely before you begin. This adorne® smart
scene controller is designed for installation in standard electrical boxes or
directly on a wall surface. However, some of the installation methods vary
slightly from traditional methods. If you do not understand these instructions
or are unsure of your abilities, seek the assistance of a qualified
electrician.
Use only with Legrand adorne® system.
-
For indoor installation only. This device can be installed in any standard electrical wall box of any gang size.
To prevent severe shock or electrocution, always disconnect power at the service panel before beginning work.
Failure to connect the ground wire will result in an unsafe installation that could lead to personal injury. -
If necessary, cut wires and strip insulation using stripping guide on back of switch.
-
WARNING
Failure to connect the ground wire will result in an unsafe installation that could lead to personal injury.
Connect frame ground wire to bare ground wire in box. Fold ground wires into back of box. Mount frame to wall box with screws provided. Tighten screws just enough to hold frame in place. Do NOT over-tighten.
TIPS- Pre-fold wires into wall box to make it easier to fit them in the box when switch is connected.
- Use caution to avoid marring wall surface with the metal frame.
Multi-Gang Electrical Box Installation
In case of multi-gang installation, replace the provided frame with adorne™
multi gang frame. While holding the frame with one hand, push the device up
slightly until it snaps out and then pull it out of the frame. Secure the
device to the multi gang frame using frame mounting screws.
Remove spacers from the frame.
Since this device fills the frame completely, you will not need the
spacers. From the back of the frame, pinch the tabs on the spacer to release.
Connect new device as shown. Make sure the terminal holes are clear. Insert wires into terminals and tighten screws securely. Do NOT over-tighten. (to 10 in. lbs.)
Connect Neutral (White) wire to WHITE. Connect Hot (Black) wire to HOT
NOTE – If you are installing multiple switches in the frame, wire all devices before snapping them into the frame.
Set Up Your System
- Download and launch the Legrand Home + Control app. The app is available on the App Store or on Google Play.
- Connect your smart device to your home network by follow-ing the step by step instructions in the app.
- Use the app to control your smart device.
Getting to Know Your Remote Scene Controller
Item | Name | Description |
---|---|---|
1 | LED Indicator | Indicates the current state of device during setup |
2 | EZ Button | Used to initiate setup |
LED Indicator Light Explanations
State of Light | Explanation |
---|---|
Blinking Green | Device is attempting to connect to the network. |
Reset to Factory Default
To manually reset the device to factory defaults press and hold the EZ button
for 7 seconds until you see the LED blink red then release. The LED will turn
off when the reset is complete Due to ongoing product improvements, Legrand
reserves the right to change specifications without notice. For the most
recent instruction sheets or more information on this product, please see this
link or scan the QR code:
https://www.legrand.us/p/wnacb46w1
Snap wall plate to frame
There are three click-stops to adjust the fit of the wall plate to the device and the wall.
NOTE: To remove wall plate, insert a small, flat screwdriver in notches on wall plate and twist gently to pry from frame.
Never apply cleaner directly to the device or wall plate. Apply to a soft cloth and use cloth to remove any smudges from the product.
Technical Assistance:
877-295-3472
www.adornemyhome.com/install
LIMITED TWO-YEAR WARRANTY
Limited two-year warranty information for adorne® products is available at
www.adornemyhome.com/warranty. Limited
warranty information for adorne® products may also be obtained free of charge
by sending a written request, along with your proof of purchase (including
purchase date), to:
Legrand
Attn: adorne Customer Service/Warranty Department 50 Boyd Avenue
Syracuse, NY 13209
No: 341400 1/24
© Copyright 2024 Legrand All Rights Reserved.
© Copyright 2024 Legrand Tous droits réservés Legrand. © Copyright 2024
Legrand Todos los derechos reservados.
60 Woodlawn Street West Hartford, CT 06110 1.877.BY.LEGRAND
(295.3472)
www.legrand.us
CANADA
905.738.9195
www.legrand.ca
References
- Search Results Page
- adorne® Warranty ⎸Legrand
- Legrand CA | Delivering and Managing Power, Light, and Data
- Legrand US | Delivering and Managing Power, Light, and Data
- The adorne® Collection | Legrand
- adorne® Warranty ⎸Legrand
- Server Error Page
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>