Product Information
Specifications
- A minimum distance of 90 mm between the transmitter’s radiating structure(s) and the user’s body or nearby persons
- Any changes or modifications not approved by the manufacturer will void the warranty and the user’s authority to operate the equipment
Getting to Know Your Switch
The switch is equipped with the following components:
- Paddle Switch: Press the top to turn the light on and press the bottom to turn it off
- LED Indicator: Indicates the current state of the device
- EZ Button: Used to enter setup mode
LED Light Explanations
- Blinking Green: The device is attempting to connect to the network
Installation
Before you start:
- Turn off the power to the device at the circuit breaker. Make sure power is off to all devices in the electrical box.
- If applicable, remove the existing device.
Break-Off Tabs for Multi-Gang Installation
Follow the instructions below for multi-gang installation:
- Break off tabs as shown in the diagram.
Wires Check
Check for the following wires:
- HOT or LINE: Receives power from the circuit box. Do not touch or let hot wire contact other wires.
- NEUTRAL: Creates a path to return current to the power source when the device is off. Required for your switch installation.
- GROUND: Provides a safe path for electricity in the event of a short.
Setup
To reset the device to factory defaults:
- Delete the device from the app.
- Press and hold the EZ button for 10 seconds until you see the LED blink red, then release.
- The LED will change to solid red when the reset is complete.
FAQ
Question: How can I contact customer support?
You can contact our customer support team via:
- Phone: 1-877-833-3303 (8:00 a.m. to 8:00 p.m. EST, Monday to Friday)
- Email: smartlighting@legrand.us
- Chat: https://www.legrand.us/radiant/smart-lighting.aspx.
BEFORE YOU START
Review this guide in its entirety. Consult an electrician with any questions or if you are unsure of your abilities.
Warning:
Incorrect installation could result in death, serious injury, and/or damage to
your home or devices.
CAUTION:
To reduce the risk of injury and/or overheating and damage to other equipment:
- Do not install to control a receptacle or a motor-controlled appliance.
- For dry, indoor use only.
- Do not use to power medical equipment.
- Connect the smart Switch to a 120 VAC, 60 Hz power source ONLY.
- Always use copper wire to install the smart Switch & follow all applicable local & national electrical codes.
WHAT YOU NEED
Required:
- Phillips-head screwdriver
- Flat blade screwdriver
You May Also Need:
Voltage tester, pliers, wire cutter, wire stripper, electrical tape,
flashlight, wiring leads (included), and wire nuts (included).
INSTALLATION
-
Turn Off Power To Device At Circuit Breaker
NOTE: Ensure power is off to all devices in the electrical box. -
Remove Existing Device (if applicable)
Check for the following wires:
- HOT or LINE: Receives power from the circuit box. Referred to as “hot” for the purpose of this guide. Do not touch or let “hot” wire contact other wires.
- NEUTRAL: Creates a path to return current to the power source when the device is off. Required for your Switch installation.
- GROUND: Provides a safe path for electricity in the event of a short circuit.
- Wire Smart Switch
- Connect the WHITE neutral wire in the box to the Neutral terminal marked “WHITE” using #12 or #14 AWG wire stranded or solid copper conductors. Strip the wire to the length shown on the back of the product. Torque to 14-16 lbf-in.
- Connect the BLACK Hot wire in the box to the Hot terminal marked “HOT” using #12 or #14 AWG wire stranded or solid copper conductors. Strip the wire to the length shown on the back of the product. Torque to 14- 16 lbf-in.
- Connect the GREEN ground wire on the Switch to the ground wire(s) in the box with the wire nut provided.
- Secure Smart Switch
- Fold wires into electrical box, taking care not to pinch a wire.
- Use included screws to secure smart Switch to electrical box.
- Snap on the radiant wall plate.
- If installing in multi-gang application, break off the tab at the top and bottom of the strap.
SETUP
This device is designed to work with a radiant® Smart Gateway with Netatmo. Follow the instructions from your app to finish setting up your Switch.
- Set UP Your System
- Download and launch the Legrand Home + Control app. The app is available on the App Store or Google Play.
- Connect your smart device to your home network by following the step-by-step instructions in the app.
- Use the app to control your smart device.
For the most recent instruction sheets or more information on this product, please see this link or scan the QR code: https://www.legrand.us/p/WNRL44wh.
GETTING TO KNOW YOUR Switch
Item | Name | Description |
---|---|---|
1 | Paddle Switch | Press the top of the paddle to turn light on. Press the |
bottom of paddle to turn light off.
2| LED Indicator| Indicates the current state of device. Refer to “LED Locator
Light Explanations” for detail.
3| EZ Button| Used to enter setup mode
Reset To Factory Default Deleting a device from the app will reset it to factory defaults. To manually reset the device to factory defaults press and hold the EZ button for 10 seconds until you see the LED blink red then release. The LED will change to solid red when the reset is complete.
LED Light Explanations
State of Light | Explanation |
---|---|
Blinking Green | The device is attempting to connect to the network |
Legrand reserves the right to change specifications without notice.
REGULATORY INFORMATION
FCC NOTICE:
This device complies with Part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesirable operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, according to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and the receiver
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 90 mm between the transmitter’s radiating structure(s) and the body of the user or nearby persons.
NOTE:
Any changes or modifications to this device that are not expressly approved by
the manufacturer will void the warranty and the user’s authority to operate
the equipment.
Contains FCC ID: 2AU5D-WNZED
IC NOTICE:
This device complies with Industry Canada license-exempt RSS standards.
Operation is subject to the following two conditions:
- This device may not cause interference; and
- This device must accept any interference, including interference that may cause undesired operation of the device.
RF EXPOSURE STATEMENT:
This equipment meets the SAR evaluation limits given in RSS-102 Issue 5
requirements at the minimum separation distance of 90 mm from the human body.
Note: Any changes or modifications to this device that are not expressly
approved by the manufacturer, will void the warranty and the user’s authority
to operate the equipment.
- IC: 25764-WNZED
- HVIN: WNRL44
Country of Origin: Made in China.
For covering patents, see www.legrand.us/patents
- 800.223.4185
- 1.877.BY.LEGRAND
- www.legrand.us
- www.legrand.ca.
© Copyright 2024 Legrand All Rights Reserved
Questions? We’re here to help.
- Phone: 1-877 833 3303 8:00 a.m. to 8:00 p.m. EST (M F)
- Email: smartlighting@legrand.us
- Chat: https://www.legrand.us/radiant/smart-lighting.aspx
(Click on the chat icon to open a dialogue box)
References
- Patents | Legrand
- Legrand CA | Delivering and Managing Power, Light, and Data
- Legrand US | Delivering and Managing Power, Light, and Data
- Patents | Legrand
- Server Error Page
- Smart Lighting from the radiant Collection ⎸Legrand
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>