MEAN WELL RSP-2000 Series 2000W Power Supply with Single Output Owner’s Manual
- June 16, 2024
- MEAN WELL
Table of Contents
MEAN WELL RSP-2000 Series 2000W Power Supply with Single Output
Product Information
Specifications
- Model: RSP-2000
- Power Supply Type: Single Output
- Power: 2000W
- Dimensions: 295 127 41 (1U) mm / 11.6 5 1.61 (1U) inch
- Input Voltage: Universal AC input / Full range
- PFC Function: Built-in active PFC function
- Efficiency: Up to 92%
- Cooling: Forced air cooling by built-in DC fan
- Output Voltage Programmable
- Current Sharing: Active current sharing up to 8000W (3+1)
- Remote Control: Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal / OTP alarm signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional Conformal Coating
- Warranty: 5 years
Applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- Digital broadcasting RF application
Description
The RSP-2000 series is a high-quality power supply with a single output. It
is designed for various applications such as factory control, test and
measurement instruments, laser machines, burn-in facilities, and digital
broadcasting RF applications. With a power output of 2000W, it provides
reliable and efficient performance.
Model Encoding / Order Information
The model encoding for the RSP-2000 series is as follows:
- RSP – 2000 – 48
- Output voltage: 48V
- Output wattage: 2000W
- Series name: RSP-2000
Specifications
Model| DC Voltage| Rated Current| Current Range| Rated Power| Ripple & Noise
(max.)| Output Voltage Adj. Range| Line Regulation| Load Regulation| Setup,
Rise Time| Hold Up Time (Typ.)| Voltage Range (Note.4,5)| Frequency Range|
Power Factor (Typ.)| Efficiency (Typ.)| AC Current (Typ.) (Note.4)| Inrush
Current (Typ.) (COLD START)| Leakage Current| Others Note
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
RSP-2000-12| 12V| 100A| 0 ~ 100A| 1200W| 150mVp-p| 10.5 ~ 14V| —| —| 1500ms,
60ms/230VAC at full load| 16ms/230VAC at 75% load 10ms/230VAC at full load| 90
~ 264VAC| 47 ~ 63Hz| 0.97/230VAC at full load| 87%| 13A/115VAC 7A/230VAC| 50A|
95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions
250 periods| Tolerance : includes set up tolerance, line regulation and load
regulation.
RSP-2000-24| 24V| 80A| 0 ~ 80A| 1920W| 200mVp-p| —| —| —| 1500ms, 60ms/230VAC
at full load| 16ms/230VAC at 75% load 10ms/230VAC at full load| 90 ~ 264VAC|
47 ~ 63Hz| 0.97/230VAC at full load| —| 16A/115VAC 10A/230VAC| —| —| Tolerance
: includes set up tolerance, line regulation and load
regulation.
RSP-2000-48| 48V| 42A| 0 ~ 42A| 2016W| 300mVp-p| —| —| —| 1500ms, 60ms/230VAC
at full load| 16ms/230VAC at 75% load 10ms/230VAC at full load| 90 ~ 264VAC|
47 ~ 63Hz| 0.97/230VAC at full load| —| 16A/115VAC 10A/230VAC| —| —| Tolerance
: includes set up tolerance, line regulation and load
regulation.
FAQ
-
What is the warranty period for the RSP-2000 series power supply?
The RSP-2000 series power supply comes with a 5-year warranty. -
Can the output voltage be adjusted?
Yes, the output voltage of the RSP-2000 series power supply is programmable. -
What are the protections provided by the RSP-2000 series power supply?
The RSP-2000 series power supply provides protections against short circuit, overload, over voltage, and over temperature. -
Is there an option for conformal coating?
Yes, the RSP-2000 series power supply has an optional conformal coating. -
What are the recommended applications for the RSP-2000 series power supply?
The RSP-2000 series power supply is suitable for various applications including factory control or automation apparatus, test and measurement instruments, laser related machines, burn-in facilities, and digital broadcasting RF applications.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 92%
- Forced air cooling by built-in DC fan
- Output voltage programmable
- Active current sharing up to 8000W (3+ 1)
- Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal / OTP alarm signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional conformal coating
- 5 years warranty
Applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- Digital broadcasting
- RF application
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
RSP-2000 is a 2KW single output enclosed type AC/DC power supply with 1U low profile. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 70°C. Moreover, RSP-2000 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
Model Encoding / Order Information
SPECIFICATION
MODEL | RSP-2000-12 | RSP-2000-24 | RSP-2000-48 |
---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 24V |
RATED CURRENT | 100A | 80A | 42A |
CURRENT RANGE | 0 ~ 100A | 0 ~ 80A | 0 ~ 42A |
RATED POWER | 1200W | 1920W | 2016W |
RIPPLE & NOISE (max.) **Note.2** | 150mVp-p | 200mVp-p | 300mVp-p |
VOLTAGE ADJ. RANGE | 10.5 ~ 14V | 21 ~ 28V | 42 ~ 56V |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% |
LINE REGULATION | ±1.0% | ±0.5% | ±0.5% |
LOAD REGULATION | ±1.0% | ±0.5% | ±0.5% |
SETUP, RISE TIME | 1500ms, 60ms/230VAC at full load | ||
HOLD UP TIME (Typ.) | 16ms/230VAC at 75% load 10ms/230VAC at |
full load
INPUT| VOLTAGE RANGE Note.4,5| 90 ~ 264VAC 250 ~
320VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| 0.97/230VAC at full load
EFFICIENCY (Typ.)| 87%| 90.5%| 92%
AC CURRENT (Typ.) Note.4| 13A/115VAC 7A/230VAC| 16A/115VAC
10A/230VAC| 16A/115VAC 10A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A
LEAKAGE CURRENT| <2mA / 240VAC
PROTECTION| OVERLOAD| 105 ~ 125% rated output power
Protection type : Constant current limiting, unit will shut down o/p voltage
after 5 sec. re-power on to recover
OVER VOLTAGE| 14.7 ~ 17.5V| 29.5 ~ 35V| 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION| OUTPUT VOLTAGE PROGRAMMABLE(PV)| Adjustment of
output voltage is allowable to 40 ~ 115% of nominal output voltage. Please
refer to the Function Manual.
CURRENT SHARING| Up to 8000W or (3+1) units. Please refer to the
Function Manual.
AUXILIARY POWER| 5V @ 0.3A, 12V @ 0.8A
REMOTE ON-OFF CONTROL| By electrical signal or dry contact Power
ON:open Power OFF:short. Please refer to the Function Manual.
REMOTE SENSE| Compensate voltage drop on the load wiring up to 0.5V.
Please refer to the Function Manual.
DC OK SIGNAL| The isolated TTL signal out. Please refer to the Function
Manual.
ENVIRONMENT| WORKING TEMP.| -35 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC **(Note 6)| SAFETY STANDARDS| UL62368-1, CSA C22.2
No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS14336-1, AS/NZS62368.1, EAC TP TC
004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32)| Class B
Radiated| BS EN/EN55032 (CISPR32)| Class A
Harmonic Current| BS EN/EN61000-3-2| —–
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55035, BS EN/EN61000-6-2, BSMI CNS13438
Parameter| Standard| Test Level / Note**
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT / Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-4-5| Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
95% interruptions 250 periods
OTHERS| MTBF| 487.7K hrs min. Telcordia SR-332 (Bellcore) ;
42.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 29512741mm (LWH)
PACKING| 1.95Kg; 6pcs/12.7Kg/1.15CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. Please contact MEANWELL for 320~370VDC application.
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Static Characteristics
Function Manual
-
Remote Sense
- The Remote Sense compensates voltage drop on the load wiring up to 0.5V
-
Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
- In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 40~115% of the nominal voltage by applying EXTERNAL VOLTAGE.
-
Remote ON-OFF Control
The power supply can be turned ON/OFF individually or along with other units by using the “Remote ON-OFF” function. -
Current Sharing with Remote Sense
RSP-2000 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below :- The power supplies should be paralleled using short and large-diameter wiring and then connected to the load.
- Difference of output voltages among parallel units should be less than 0.2V.
- The total output current must not exceed the value determined by the following equation: Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9
- Under parallel operation, the minimum output load should be greater than 5% of total output load; otherwise, it is likely that only one unit operates whereas other units may enter standby mode or their LED status indicators may not turn on.
- When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit)×(Number of unit) the current shared among units may not be fully balanced.
- CN502/CN504 Function pin connection.
Mechanical Specification
Pin No. | Function | Description |
---|---|---|
1 | +S | Positive sensing for remote sense. |
2 | -S | Negative sensing for remote sense. |
3 | PV | Connection for output voltage programming. (Note.1) |
4 | GND | This pin connect to the negative terminal(-V). |
5 | DC-OK | High (4.5 ~ 5.5V) : When the Vout ≦80%±6%. Low (0 ~ 0.5V) : When |
Vout ≧80%±6%.
The maximum sourcing current is 10mA and only for output. (Note.2)
6| T-ALARM| High (4.5 ~ 5.5V) : When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm.
Low (0 ~ 0.5V) : When the internal temperature (TSW1 or TSW2 short) under the limit temperature. The maximum sourcing current is 10mA and only for output. (Note.2)
7| Remote ON-OFF| The unit can turn the output on and off by electrical signal
or dry contact between Remote ON-OFF and +5V-AUX. (Note.2) Short (4.5 ~
5.5V) : Power OFF ; Open (0 ~ 0.5V) : Power ON ; The maximum input voltage is
5.5V.
8,9,10| GND-AUX| Auxiliary voltage output GND.
The signal return is isolated from the output terminals (+V & -V).
11| +5V-AUX| Auxiliary voltage output, 4.5~5.5V, referenced to GND-AUX.
The maximum load current is 0.3A. This output has the built-in “Oring diodes” and is not controlled by the Remote ON-OFF control.
12| +12V-AUX| Auxiliary voltage output, 10.6~13.2V, referenced to GND-AUX.
The maximum load current is 0.8A. This output has the built-in “Oring diodes” and is not controlled by the Remote ON-OFF control.
Note 1: Non-isolated signal, referenced to the output terminals (-V).
Note 2: Isolated signal, referenced to GND-AUX.
LED Indicators & Corresponding Signal at Function Pins
Signal between function pin and “GND-AUX”.
Control Pin No. Assignment (CN502) : HRS DF11-6DP-2DSA or equivalent
Mating Housing | HRS DF11-6DS or equivalent |
---|---|
Terminal | HRS DF11-**SC or equivalent |
Pin No. | Function |
--- | --- |
1,2 | DA |
3,4 | DB |
5,6 | GND |
Control Pin No. Assignment (CN504):
Pin No. | Function | Description |
---|---|---|
1,2 | Terminal resistance | CN504 is the selector of terminal resistor that is |
designed for DA/DB signals and parallel control function.
AC Input Terminal Pin No. Assignment
DC Output Terminal Pin No. Assignment
Installation Manual
Please refer to: http://www.meanwell.com/manual.html
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>