OREIN 100CFM Bathroom Exhaust Fan with Light User Guide

June 16, 2024
OREIN

OREIN 100CFM Bathroom Exhaust Fan with Light

We appreciate the trust and confidence you have placed in OREiN through the purchase of VENTILATION FAN with LED LIGHT. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.
Thank you for choosing OREiN.

Safety Information

Please read and understand this entire manual before attempting to assemble, operate or install the product.

  1. Always disconnect the power supply prior to servicing the fan, motor or junction box.
  2. Follow all local building, safety and electrical codes as well as NEC (National Electrical Code) and OSHA (Occupational Safety and Health Act).
  3. Electric Service supply must be 120 volts, 60 hertz.
  4. This product must properly connect to the grounding conductor of the supply circuit.
  5. Do not bend or kink the power wires.
  6. Do not use this fan with any solid state control device, such as a remote control, dimmer switch, or certain timers. Mechanical timers are not solid state devices.
  7. Do not install in a ceiling with insulation greater than R50.
  8. Duct work should be installed in a straight line with minimal bends.
  9. Duct work size must be the same size as the discharge and should not be reduced. Reducing the duct size may increase fan noise.
  10. To ensure the performance, please use the recommended dimmers in the list if necessary.

WARNING: To reduce the risk of fire, electric shock, or injury to persons, observe the following:

  1. Use this unit in the manner intended by the manufacturer. If you have any questions. Please call customer service.

  2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

  3. Installation work and electrical wirina must be done by a qualified person) in accordance with all applicable codes and standards, including fire-rated construction.

  4. Sufficient air is needed for proper combustion and exhausting of gases through the flue ( chimney) of fuel-burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association
    (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASH RAE) and local code authorities.

  5. When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.

  6. Ducted fans must always be vented to the outdoors.

  7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.

  8. FOR USE IN ONE- AND TWO-FAMILY DWELLINGS ONLY.

  9. TYPE IC-INHERENTLY PROTECTED

  10. FOR USE IN NON-FIRE-RATED INSTALLATIONS ONLY.

  11. SUITABLE FOR DAMP LOCATIONS

CAUTION : For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
CAUTION : Not for use in cooking areas.
CAUTION : To reduce the risk of injury to persons, install the fan at least 7 feet (2.1 m) above the floor.

Product Specification

SPECIFICATIONS

Airflow: 110 CFM Main light: 1500Im Night light: 200Im
Voltage: 120 V, 60 Hz
Duct diameter: 4 in.
Sound output: 2 Sones
SPECIFICATIONS

Power consumption: 120V AC, 60Hz, Fan 27W, Light 20W
Weight: 10.95 lbs .
Ceilin g Opening Dimension Requirements : 8 . 11 in. (L) x 7.48 in. (W) .

Typical Installation
The ducting from this fan to the outside of the building has a strong effect on the airflow, noise and energy use of the fan. Use the shortest, straight­est duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.

Wiring Diagram

WARNING
Wiring must comply with all applicable electrical codes. Turn OFF power before removing or installing connectors
WARNING
COPPER TO COPPER ONLY. Do not use Alumi­num wire.

Warranty

LIMITED LIFETIME WARRANTY
WHAT IS COVERED
If this product fails due to a defect in materials or workmanship at any time during the first FIVE years of ownership, the manufacturer will replace it free of charge, postage-paid at their option. This warranty does not cover products that have been abused, altered, damaged, misused, cut or worn. This warranty does not cover use in commercial applications. Use only manufacturer- supplied genuine warranty repair replacement parts to repair this fan. Use of non-genuine repair parts will void your warranty. The manufacturer DISCLAIMS all other implied or express warranties including all warra-ties of merchant ability and/or fitness for a particular purpose. As some states do not allow exclusions or limitations on an implied warranty, the above exclusions and limitations may not apply. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation, repair, replacement as well as incidental and consequential damages connected with the above are excluded. Any damage to this product as a result of neglect, misuse, accident, improper installation or use other than the purpose SHALL VOID THIS WARRANTY. Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.
Customer Service or visit www.iorein.com.

Pre-installation

PLANNING INSTALLATION
Before beginning assembly of the product, make sure all parts are present. Compare parts with the package contents list and hardware contents. If any part is missing or damaged, do not attempt to assemble the product.

  • WARNING: Turn off electricity at breaker box before beginning  installation.

Carefully remove the unit from the carton.
Check area above installation location to be sure that for proper ventilation. wiring can run to the planned location and that duct work can be run and the area is sufficient for proper ventilation.
Inspect duct work and wiring before proceeding with installation.
Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work.

NOTE: Installation may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath fan are not all included. However, most are available at your local home improvement or hardware store.

TOOLS REQUIRED (not included)

PACKAGE CONTENTS


Part| Description| Quantity
A| Fan housing| 1
B| Grille with light| 1
C| Wire nut| 5
D| Joist screw| 4
E| Short screw| 1
F| Wire cover| 1
G| Flex bracket| 1
H                      Drywall cover board                       1

Installation – New Construction with Flex Bracket

CAUTION: Make sure power is switched off at service panel before starting installation. Wear gloves during installing to help protect your hands from injury.
NOTE: Ceiling mount only.

Install the flex bracket

  • Bend down 4 tabs on the side of flex bracket (G) for positioning, pre-install the flex bracket to joists by using 2 screws (D) on one side.
  • Adjust the length of flex bracket (G) to fit the spacing between the joists (12in. to 22in.). Attach the flex bracket with the other 2 screws (D).
  • Please make sure the bottom of the flex bracket will be flush with the bottom of the joists.

Adjust the tabs of fan housing
Pull the 4 tabs (AA) of the fan housing into the vertical position.

Install the fan housing on bracket

  • Align the 4 tabs (AA) on the fan housing through the slots on the flex bracket (G). Then insert the tabs through the slots until the fan housing (A) sitting on the flex bracket (G).
  • Then bend the tabs (AA) to both sides to attach the fan housing firmly on the flex bracket (G).

Connect the wire

  • Loosen the short screw (E) and remove the wire cover (F).
  • Pull the house wires through the knockout of wire cover (F). Using the wire nuts (C) to connect 120 V AC house wiring from the wall switch to the fan as shown in the wiring diagram on page 3. Please tighten the wire nuts with the wires.
  • Carefully push the connected wires back into the wiring compartment of the fan housing (A). Reattach the wire cover (F) and attach it firmly with the short screw (E).

CAUTION: If the electrical wires do not match the colors listed, you must determine what each house wire represents before connecting. You may need to consult an electrical contractor to determine safety.

Connect the duct

  • Connect a 4 in. circular duct (not supplied) and vent to the duct connector. Secure it with duct tape (not supplied) or a clamp (not supplied) to make the connection secure and airtight.
  • Turn on the power source. Check the fan for any abnormal sound or vibration.

CAUTION : After checking the fan, please remember to turn off the power before next installation step.

Finish the ceiling work

  • After electrical and construction inspection is completed, the drywall ceiling can be installed.
  • Cut the ceiling hole with the cut-hole template (H) or the size 8.11 7.48 inches (206190mm). Ceiling hole should be
  • aligned with the inside edge of fan housing.
    Important : Cover and sear up all gaps with duct tape

NOTE : That it is common practice in heating and ventilation LJ systems using sheet metal ductwork and fittings or flexible duct ? NOTE: That it is common practice in heating and ventilation LJ systems using sheet metal ductwork and fittings or flexible duct

Select the light color

Select desired LED color temperature by sliding the toggle switch on the back of the grille (B).

Install the grille with light

  • Attach the grille by squeezing one spring together and inserting the springs into the spring guides in the fan housing (A) firstly.
  • Connect LED wire to the plug in the fan housing.
  • Then insert another spring and push the grille (B) up against the ceiling.
  • Check that the installation is secure and safe from falling objects.

Installation – New Construction without Flex Bracket

CAUTION:   Make sure power is switched off at service panel before starting installation. Wear gloves during installing to help protect your hands from injury.

NOTE: Ceiling mount only.

Remove the duct connector and wire cover

  • To remove duct connector, pull up on the finger latch, then slide the duct connector up until until it is removed from the fan housing (A).
  • Loosen the short screw (E) and remove the wire cover (F).

Mount the housing to the joist

  • Bend down 2 tabs (BB) on outside of housing to locate and position against bottom of joist for proper position.
  • Secure fan housing (A) through mounting keyholes on bracket with with 4 screws (D). Make sure bottom of fan housing will be flush with finished ceiling.

Connect the wire

  • Pull the house wires through the knockout of wire cover (F). Using the wire nuts (C) to connect 120 V AC house wiring from the wall switch to the fan as shown in the wiring diagram on page 3. Please tighten the wire nuts with the wires.
  • Carefully push the connected wires back into the wiring compartment of the fan housing (A). Reattach the wire cover (F) and attach it firmly with short screw (E).

Connect the duct

  • Connect a 4 in. circular duct (not supplied) and vent to the duct connector. Secure it with duct tape (not supplied) or a clamp (not supplied) to make the connection secure and air tight.
  • Insert the duct connector back to the fan housing (A) follow the guide slot from up to down. And it will be in place with a “click” sound. Please secure it tightly.

Select the light color
Select desired LED color temperature by sliding the toggle switch on the back of the grille (B).

Finish the ceiling work

  • After electrical and construction inspection is completed, the dry wall ceiling can be installed.
  • Cut the ceiling hole with the cut-hole template (H) or the size 8.11 7.48inch (206190mm). Ceiling hole should be aligned with the inside edge of fan housing.
  • Important: Cover and seal up all gaps with duct tape
  • NOTE : MAKE SURE ONE EDGE OF THE OPENING IS FLUSH t:J WITH THE JOIST FOR INSTALLATION.
  • NOTE : That it is common practice in heating and ventilation U systems using sheet metal ductwork and fittings or flexible duct work tubing to use duct tape or aluminum tape to ensure air tight seals and improve efficiency.

Install the grille with light

  • Attach the grille by squeezing one spring together and inserting the springs into the spring guides in the fan housing (A) firstly.
  • Connect LED wire to the plug in the fan housing. Then insert another spring and push the grille (B) up against the ceiling.
  • Check that the installation is secure and safe from falling objects.

Installation – Existing Construction

Remove the existing fan
CAUTION: Make sure power is switched off at service panel before starting installation.  Wear gloves during installing to help protect your hands from injury.

Remove the old fan from the ceiling.

Finish the ceiling work

  • After electrical and construction inspection is completed, the dry wall ceiling can be installed.
  • Cut the ceiling hole with the cut-hole template (H) or the size 8.11 7.48inch (206190mm). Ceiling hole should be aligned with the inside edge of fan housing.

Remove the duct connector and wire cover

  • To remove duct connector, pull up on the finger latch, then slide the duct connector up to down until it is removed from the fan housing (A).
  • Loosen the short screw (E) and remove the wire cover (F).

Place the fan housing
Place the fan housing (A) inside the ceiling through the hole. And then place on the side. Shown as in picture.

Connect the wire

  • Pull the house wires through the knockout of wire cover (F).
  • 5 Using the wire nuts (C) to connect 120 V AC house wiring from the wall switch to the fan as shown in the wiring diagram on page 3. Please tighten the wire nuts with the wires.
  • Carefully push the connected wires back into the wiring fan housing (A). Reattach the wire cover (F) attach it firmly with the short screw (E).

Connect the duct

  • Connect a 4 in. circular duct (not supplied) and vent to the duct connector. Secure it with duct tape (not supplied) or a clamp (not supplied) to make the connection secure and air tight.
  • Insert the duct connector back to the fan housing (A) follow the guide slot from up to down. And it will be in place with a “click” sound. Please secure it tightly.

Install the flex bracket

  • Put the flex bracket (G) inside the ceiling through hole.
  • Fix the flex bracket (G) onto the joists with 4 screws (D). The flex bracket is adjustable to fit different space (7 2~22inches) between the joists.
  • Please make sure the bottom of the flex bracket will be flush with the bottom of the joists.

Adjust the inserts of fan housing
Pull the 4 tabs (AA) of the fan housing into the vertical position.

Install the fan housing on bracket

  • Align the 4 tabs (AA) on the fan housing through the slots on the flex bracket (G). Then insert the tabs through the slots until the fan housing (A) sitting on the flex bracket (G).
  • Then bend the tabs (AA) to both sides to attach the fan housing firmly on the flex bracket (G).
  • Important : Cover and seal up all gaps with duct tape

NOTE: That it is common practice in heating and ventilation systems using sheet metal ductwork and fittings or flexible duct work tubing to use duct tape or aluminum tape to ensure air tight seals and improve efficiency.

Select the light color
Select desired LED color temperature by sliding the toggle switch on the back of the grille (B).

Install the grille with light

  • Attach the grille by squeezing one spring together and inserting the springs into the spring guides in the fan housing (A) firstly.
  • Connect LED wire to the plug in the fan housing.
  • Then insert another spring and push the grille (B) up against the ceiling.
  • Check that the installation is secure and safe from falling objects.

Light Mode Operation

  • To change to night light mode while using the main light, switch the wall switch off then back on again within 2 seconds.
  • To change to main light mode while using night light mode, switch the wall switch off then back on again within 2 seconds.

Care and Maintenance

WARNING: Disconnect power supply before servicing.

  • See SAFETY INFORMATION before proceeding. Routine maintenance should be done at least once a year.
  • Never use solvents, thinner or harsh chemicals for cleaning the fan.
  • Do not allow water to enter the motor.
  • Do not immerse metal parts in water.

Troubleshooting

WARNING

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause un­desired operation.

NOTE :This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment gen­erates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio ortelevision reception, which can be determined byturn­ing the equipment off and on, the user is encouraged to try to correct the inter­ference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experi­enced radio/TVtechnician for help.

Made in China

SYVIO TECHNOLOGY CO, LIMITED Room A, 8/F, Kwok Cheung Building, 635-637 Shanghai Street, Mong Kok, Hong Kong
300 Technology Court SE Suite 100,Smyrna, GA 30082
1 844-506-1530
www.1ore1n.com support@iorein.com
Follow us on social media D Facebook: @orein.led D Youtube: OREiN LED

Scan the brand code to get the instruction videos of how to use

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals