HATHEPHS AJ-961SC Smoke And Carbon Monoxide Alarm User Guide

June 16, 2024
HATHEPHS

HATHEPHS AJ-961SC Smoke And Carbon Monoxide Alarm

HATHEPHS-AJ-961SC-Smoke-And-Carbon-Monoxide-Alarm-
PRODUCT

Product Information

Specifications

  • Model: AJ-961SC
  • Weight: 190g
  • Compliance: UL217 & UL2034
  • Carbon Monoxide Detection Levels: 70PPM, 150PPM, 400PPM
  • Smoke Detection Time: 60-240 minutes
  • Carbon Monoxide Detection Time: 10-50 minutes
  • Alarm Sounding Time: 4-15 minutes

Product Usage Instructions

1. Function Description

This section provides information about the various functions and features of the combination smoke & carbon monoxide alarm.

2. LCD Display

This section explains the information displayed on the LCD screen of the alarm.

3. Important Safety Information

This section highlights important safety precautions for the proper use of the alarm.

4. Where to Locate

This section guides users on the ideal locations to install the alarm for optimal performance.

5. Locations to Avoid

This section provides information on areas where the alarm should not be installed.

6. Mounting Steps

This section outlines the steps to mount the alarm on a wall or ceiling using screws and plastic anchor plugs.

7. Deactivation of Alarm

This section explains how to permanently deactivate the alarm at the end of its 10-year life.

8. Testing the Smoke & CO Alarm

This section provides instructions on how to test the alarm to ensure its proper functioning.

9. Maintenance and Cleaning

This section provides guidelines for the regular maintenance and cleaning of the alarm.

10. Practice Fire Safety

This section emphasizes the importance of practicing fire safety measures in conjunction with using the smoke & CO alarm.

11. If the Smoke/CO Alarm Sounds

This section provides instructions on what to do if the alarm sounds an emergency alert.

12. Limitations of Smoke & CO Alarms

This section outlines the limitations and potential shortcomings of smoke & CO alarms.

13. Manufacturer and Service Information

This section provides the contact details of the manufacturer for any service- related inquiries or information.

FAQ

How often should I test the smoke & CO alarm?

Test alarms weekly and upon returning from vacation or when no one has been in the household for several days. Stand at arm’s length from the smoke & CO alarm when testing. The alarm horn is loud to alert you to an emergency and can be harmful to hearing. Press the button for 2 seconds. The alarm will sound loud short beeps. The alarm may stop sounding once releasing the test button.

How do I mount the smoke & CO alarm on a wall or ceiling?

Follow these steps:

  1. Drill two 6.0 mm holes in the wall or ceiling.
  2. Insert two plastic anchor plugs into the holes with a hammer.
  3. Attach the mounting bracket to the surface of the wall or ceiling with two screws.
  4. Mount the alarm into the bracket by pushing them together and twisting the unit clockwise.
  5. Test the unit by using the Test/Silence button. Ensure the unit sounds in an alarm pattern.

How do I deactivate the smoke & CO alarm?

The deactivation of the alarm is permanent and unrecoverable. To deactivate the alarm at the end of its 10-year life, break the label with a screwdriver and insert a screwdriver into the slot. Push the plastic plate inward, and the alarm will be deactivated.

IMPORTANT!

This user manual contains important information about your combination smoke & carbon monoxide alarm’s operation. To ensure proper use and trouble-free operation, please read this manual carefully and store it in a safe place for future reference.

PACK LIST

HATHEPHS-AJ-961SC-Smoke-And-Carbon-Monoxide-Alarm-
FIG-4 HATHEPHS-AJ-961SC-Smoke-And-
Carbon-Monoxide-Alarm-FIG-5

CONTENTS

  1. FUNCTION DESCRIPTION
  2. LCD DISPLAY
  3. IMPORTANT SAFETY INFORMATION
  4. WHERE TO LOCATE
  5. LOCATIONS TO AVOID
  6. MOUNTING STEPS
  7. DEACTIVATION OF ALARM
  8. TESTING THE SMOKE & CO ALARM
  9. MAINTENANCE AND CLEANING
  10. PRACTICE FIRE SAFETY
  11. IF THE SMOKE/CO ALARM SOUNDS
  12. LIMITATIONS OF SMOKE & CO ALARMS
  13. MANUFACTURER AND SERVICE INFORMATION

FUNCTION DESCRIPTION

Make sure to power on the alarm before operation. Buckle the base with the alarm will turn on the device automatically or turn on the switch manually.

  1. Testing
    Test your alarm by pressing the Test/Hush button and the unit will proceed to 3 long beeps with the red LED flashing 3 times. After 2 seconds of silence, the unit will proceed to 4 short beeps with the red LED flashing 4 times.

  2. Hush button
    Press the test button during an alarm to make the unit enter silence mode. If the smoke and CO concentration still exceeds the alarm threshold, the unit will enter another alarm state. Otherwise, the unit will exit the silence mode after 9 minutes and resume normal operation.

  3. CO alarm levels
    The unit is programmed to sound an alarm at the following CO concentrations within the time periods listed:HATHEPHS-AJ-961SC-Smoke-And-Carbon-Monoxide-
Alarm-FIG-6

ATTENTION:

When the carbon monoxide concentration is greater than or equal to 300PM, the device cannot be muted.

  1. Battery indicator:
  2. Concentration indicator:

LCD DISPLAY

HATHEPHS-AJ-961SC-Smoke-And-Carbon-Monoxide-Alarm-
FIG-7 HATHEPHS-AJ-961SC-Smoke-And-
Carbon-Monoxide-Alarm-FIG-8

IMPORTANT SAFETY INFORMATION

WARNING!

  • DO NOT remove or disconnect the battery to quiet unwanted alarms. This will remove your protection. Open windows or fan the air around smoke & CO alarm to silence it. The test button accurately tests all smoke & CO alarm functions. DO NOT use any other test method. Test smoke & CO alarm weekly to ensure proper operation.This smoke & CO alarm IS NOT designed to be the PRIMA-  RY protection for buildings that require complete fire alarm systems. Buildings of this type include hotels, motels, dormitories, hospitals, nursing homes, and group homes
  • This is true even if they were once single-family homes. However, this smoke & CO alarm MAY be used inside individual rooms as SUPPLEMENTAL protection.
  • Install a smoke & CO alarm in every room and on every level of the home. Smoke may not reach the smoke & CO alarm for many reasons. For example, if a fire starts in a remote part of the home, on another level, in a chimney,  wall, roof, or on the other side of a closed door, smoke may not reach the smoke & CO alarm in time to alert household members. A smoke & CO alarm will not promptly detect a fire EXCEPT in the area or room in which it is installed.
  • Smoke & CO alarms may not alert every household member every time. The alarm horn is loud in order to alert individuals to a potential danger. However, there may be limiting circumstances where a household member may not hear the alarm (i.e., outdoor or indoor noise, sound sleepers, drug or alcohol usage, the hard of hearing, etc.). If you suspect that this smoke & CO alarm may not alert a household member, install and maintain specialty Smoke & CO alarms. Household members must hear the alarm’s warning sound and quickly respond to it to reduce the risk of damage, injury, or death that may result from fire. If a household member is hard of hearing, install special smoke alarms with lights or vibrating devices to alert occupants.
  • Smoke & CO alarms can sound their alarms only when they detect smoke / CO. Smoke & CO alarms detect combustion particles in the air. They do not sense heat, flame, or gas. This smoke & CO alarm is designed to give audible warning of a developing fire. However, many fires are fast-burning, explosive, or intentional. Others are caused by carelessness or safety hazards. Smoke may not reach the smoke & CO alarm QUICKLY ENOUGH to ensure safe escape. Smoke & CO alarms have limitations. This smoke & CO alarm is not foolproof and is not warranted to protect lives or property from fire. Smoke & CO alarms are not a substitute for insurance. Homeowners and renters should insure their lives and property. In addition, it is possible for the smoke & CO alarm to fail at any time. For this reason, you must test the smoke & CO alarm weekly and replace every 10 years.

WHERE TO LOCATE

  1. As a minimum, smoke & CO alarms should be located between sleeping areas and potential sources of fire such as living rooms and kitchens. In single story homes with one sleeping area, a smoke & CO alarm should be installed in the hallway, as close as possible to the living accommo- dation. To ensure audibility in bedrooms, no smoke & CO alarm should be further away than 3m from any bedroom door. It may be necessary to install more than one smoke & CO alarm, particularly the hallway is more than 15m long. In single story homes with two separate sleeping areas, a minimum of two smoke & CO alarms is required, one outside each sleeping area. In multilevel or split level homes, as a minimum a smoke & CO alarm should be installed on the ground floor between the staircase and any rooms in which a fire might start and on each story in circulation areas which form part of escape route (normally hallways and landings),
  2. Additional alarms should be installed in bedrooms in anticipation of fires originating here, caused by faulty wiring, lights, appliances, smokers or other hazards.
  3. For best protection, smoke & CO alarms should be installed in every room in your home, apart from those listed in the Section 4 LOCATIONS TO AVOID. Heat alarms should be used in kitchens, boiler rooms, laundry, rooms, garages and such like, where smoke & CO alarms would be unsuitable.
  4. Install smoke & CO alarms in circulation areas at a distance no greater than 7.5m from the farthest wall, no greater than 75m from a door to any room in which a fire might start and no greater than 7.5m from the next smoke & CO alarm.
  5. As it is impossible to predict the source of a fire, the best location for an alarm is usually the center of a room or hallway. If it is necessary to place a smoke & CO alarm on a wall, always locate the detection element of the alarm 150mm to 300mm(6 to 12 inches) below the ceiling and the bottom of the alarm above the level of doors and other openings.
  6. In rooms with simple sloped, peaked or gabled ceilings, install smoke & CO alarms on the ceiling 900mm(3feet) from the highest point of the ceiling. “Dead air” at the peak of a ceiling may prevent the smoke from reaching the alarm in time to provide an early warning.
  7. Read Section 4. LOCATIONS TO AVOID and Section and 13. LIMITATIONS OF SMOKE & CO ALARMS in this manual.

CAUTION:
Research indicates that substantial increases in warning time can be obtained with each properly installed, additional alarm. It is strongly recommended that advice in above be followed to ensure maximum protection.HATHEPHS-AJ-
961SC-Smoke-And-Carbon-Monoxide-Alarm-FIG-9

IMPORTANT:

These alarms are intended to primarily for single-occupancy private dwellings. For use in other applications, the manufacturer’s advice must be sought.

LOCATIONS TO AVOID

DO NOT locate smoke & CO alarms:

  1. In turbulent air from fans, heaters, doors, windows, etc., which could draw smoke or Carbon monoxide gas away from the alarm.
  2. In high humidity area such as bathrooms and shower rooms, or where the temperature exceeds 39 C (100°F) or falls below 5C(40°F), as high humidity can trigger nuisance alarm.
  3. At the peal of an “A” frame ceiling. “Dead air” at the top may prevent smoke or carbon monoxide gas from reaching the alarm in time to provide early warning.
  4. Less than 300mm(12 inches) from the wall when mounted on the ceiling.
  5. In insect-infested areas. Tiny insects may affect performance.
  6. In kitchens, boiler rooms, laundry rooms, garages. Combustion particles from cooking or car exhaust and dust and moisture could trigger a nuisance alarm.
  7. In very dusty or dirty areas. Dirt and dust can build up and impair performance.
  8. Within 300mm(12 inches)of light fittings or room corners.
  9. In locations which would make routine testing or maintenance hazardous (e.g.over a stairwell).
  10. On Poorly insulated walls or ceilings.
  11. Near objects such as ceiling decorations which might impede the path of smoke to the alarm.
  12. Within 1500mm (5 feet) of fluorescent light fittings.

Mounting Steps

  1. Drill two @ 6.0 mm holes in the wall or ceiling, then insert two plastic anchor plugs into the holes with a hammer.
  2. Attach the mounting bracket to the surface of the wall or ceiling with two screws and mount the alarm into the bracket by pushing them together and twisting the unit clockwise.
  3. Test the unit by using the Test/Silence button. Ensure the unit sounds in an alarm pattern.

Note: This model is equipped with a feature that automatically activates the alarm when the alarm is attached to the mounting bracket for the first time.

DEACTIVATION OF ALARM

WARNING

The deactivation of alarm is permanent and unrecoverable. Please deactivate the alarm at the end of the 10-year life.  Break the label with a screwdriver and insert a screwdriver into the slot and push the plastic plate inward, then the alarm will be deactivated.

TESTING THE SMOKE & CO ALARM

WARNING:

Test each smoke & CO alarm to be sure it is installed  correctly and operating properly, The test button accurately tests all functions. DO NOT usean open flame or CO gas exposure in the air to test this  smoke & CO alarm. You many ignite and damage thesmoke & CO alarm or your home. Test alarms weekly and upon returning from vacation or when no one has been in the household for several days. Stand at arm’s length from the smoke & CO alarm when testing. The alarm horn is loud to alert you to an emergency and can be harmful to hearing. Press the but ton 2 seconds. The alarm will sound loud short beeps. The alarm may stop sounding once releasing the test button.
NOTE: REPLACE THE ALARM IF THE TEST FUNCTION DOES NOT OPERATE PROPERLY AFTER FOLLOWING THE PROCEDURES OUTLINED ABOVE.
DANGER: If alarm buzzer sounds, and smoke & CO alarm is not being tested, the smoke & CO alarm is sensing smoke or carbon monoxide.
THE SOUND OF THE ALARM HORN REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION.

MAINTENANCE AND CLEANING

This unit has been designed to be as maintenance-free as possible, but there are a few simple things you must do to keep it working properly:

  1. Test it at least once a week.
  2. Clean the smoke & CO alarm at least once a mouth; Gentally vacuum the outside of the smoke & CO alarm using your household vacuum’s soft brush attachment. Test the smoke & CO alarm. Never use water, cleaners or solvents since they may damage the unit.
  3. If the smoke & CO alarm becomes contaminated by excessive dirt, dust and/or grime, and cannot be cleaned to avoid unwanted alarms, replace the unit immediately.
  4. Relocate the unit if it sounds frequent unwanted alarms. See Section 4 LOCATIONS TO AVOID for details.
  5. When the battery becomes weak, the smoke & CO alarm will sound onetime one beeps every 60s seconds and Red LED flashes onetime(the low battery warning). You should replace the alarm immediately to continue your protection.

PRACTICAL FIRE SAFETY

If the smoke & CO alarm sounds its alarm horn, and you have not pushed the test button, it is warning of a danger ous situation. Your immediate response is necessary. To prepare for such occurrences, develop family escape plans, discuss them with ALL household members, and practice them regularly.

  1. Expose everyone to the sound of a smoke & CO alarm and explain what the sound means.
  2. Determine TWO exits from each room and an escape route to the outside from each exit.
  3. Teach all household members to touch the door and use an alternate exit if the door is hot. INSTRUCT THEM NOT TO OPEN THE DOOR IF THE DOOR TEMPERATURE IS HIGH.
  4. Teach household members to crawl along the floor to stay below dangerous smoke, fumes, and gases.
  5. Determine a safe meeting place for all members outside the building.

IF THE SMOKE/CO ALARM SOUNDS

  1. Don’t panic; stay calm.
  2. Leave the building as quickly as possible. Touch doors to feel if they are hot before opening them. Use an alternate exit if necessary. Crawl along the floor, and DO NOT stop to collect anything.
  3. Meet at a pre-arranged meeting place outside the building.
  4. Call the fire department from OUTSIDE the building.
  5. DO NOT GO BACK INSIDE A BURNING BUILDING. Wait for the fire department to arrive.

NOTE: These guidelines will assist you in the event of a fire. However, to reduce the chance that fires will start, practicefire safety rules and prevent hazardous situations.

LIMITATIONS OF SMOKE & CO ALARMS

Smoke & CO alarms have played a key role in reducing deaths resulting from home fires and CO poisoning worldwide. However, like any warning device, Smoke & CO Alarms can only work if they are properly located, instaled, and maintained, and if smoke & CO reaches the Alarms. They are not foolproof.

  1. Smoke & CO alarms may not waken all individuals. Practice the escape plan at least twice a year, making sure that everyone is involved – from kids to grandparents. Allow children to master fire escape planning and practice before holding a fire drill at night when they are sleeping. If children or others do not readily waken to the sound of the smoke & CO alarm, or if there are infants or family members with mobility limitations, make sure that someone is assigned to assist them in fire drill and in the event of an emergency. It is recommended that you hold a fire drill while family members are sleeping in order to determine their response to the sound of the smoke & CO alarm while sleeping and to determine whether they may need assistance in the event of an emergency.
  2. Smoke & CO alarms cannot detect fires if the smoke does not reach the alarms. Smoke from fires in chimneys or walls, on roofs, or on the other side of dosed doors may not reach bedroom or sleeping area-especially if bedroom or sleeping area doors are closed at night and in the hallway between them.
  3. Smoke & CO alarms may not have time to alarm before the fire itself causes damage, injury, or death, since smoke from some fires may not reach the unit immediately. Examples of this include persons smoking in bed, children playing with matches, or fires caused by violent explosions resulting from escaping gas.
  4. Smoke & CO alarms are not foolproof. Like any electronic device, smoke & CO alarms are made of components that can wear out or fail at any time. You must test the unit weekly to ensure your continued protection. Smoke & CO alarms cannot prevent or extinguish fires. They are not a substitute for property or life insurance.
  5. Smoke & CO alarms have a limited life. The unit should be replaced immediately if it is not operating properly. You should always replace a smoke & CO alarm after 10 years from date of purchase. Write the purchase date on the space provided on back of unit.