HATHEPHS CS01 Smoke Monoxide Detector Alarm User Guide

June 14, 2024
HATHEPHS

SMOKE AND CARBON
MONOXIDE ALARM
Quick Reference Guide

CS01 Smoke Monoxide Detector Alarm

HATHEPHS CS01 Smoke Monoxide Detector Alarm

Model: CS01

Thank you for purchasing our smoke and carbon monoxide alarm device. Please read this manual carefully to ensure proper use and store it in a safe place for future reference.

Product Specifications

Power Supply DC3V CR14505 lithium battery
Battery Life 10 years
Sensor Type Smoke: Photoelectric CO: Electrochemical
CO Sensitivity 50 ppm: 60-90 minutes

100 ppm: 10-40 minutes
300 ppm: 1-3 minutes
Operating Temperature| 14-104 F (-10-40°C)
Coverage Area| 215-430 ft2(20-40 II)
Operating Relative Humidity| ≤ 95%RH (non-condense)
Audible Alarm| ≥ 85dB at 10ft (3m)
Silence Duration| About 10 minutes

Packing List

1 X Smoke and carbon monoxide alarm
1 x Mounting bracket
1 x Screw kit
1 x Adhesive tape
1 x User manual

Product profile:

HATHEPHS CS01 Smoke Monoxide Detector Alarm - Product
profile

NOTE: The Test/ Silence button is the entire top cover.

Installation Instructions

Where to install

  1. At first you should install an alarm in the bedroom and walkway. If there are several bedrooms in the house, please install an alarm in every bedroom.
  2. Install an alarm above the stairway and on every floor of the house.
  3. Smoke, heat and burning things will spread horizontally after rising to the ceiling, so install the alarm in middle of the ceiling.
  4. If the alarm can not be installed in the middle of the ceiling, install it keeping 300mm away from the corners • (see the figure 1).
  5. If the alarm is installed in the wall, it should keep 1 00mm away from the ceiling.
  6. If the length of the room or the hall is beyond 30 feet, you need to install several alarms there.
  7. When the wall or ceiling is slanting, the alarm needs to be installed minimum 500mm away from the highest wall or ceiling point in the room (see the figure 2).

HATHEPHS CS01 Smoke Monoxide Detector Alarm - install

Recommended Placement

HATHEPHS CS01 Smoke Monoxide Detector Alarm -
Placement

Locations to Avoid

  1. High-humidity areas such as bathrooms;
  2. Next to air outlets, fans and central heating;
  3. Dusty, dirty areas or areas with insects;
  4. High-temperature and easily polluted places;
  5. Places with difficult access, making it difficult to operate the test function;
  6. Within l .5m from lamps;
  7. Next to doors or windows;
  8. In the top of rooms with sloping roofs, the corner of the room or other dead-air spaces.

Mounting Alarms

  1. Twist off the mounting bracket from the alarm.
  2. Put the bracket on the installation position and mark the screw holes on the ceiling or the wall.
  3. Drill two mounting holes in the marked place by an electric drill (The diameter of the drill hole is 5mm) and insert two plastic anchor plugs by hammer.
  4. Screw the mounting bracket to the ceiling or the wall (Refer to figure 3).
  5.  Attach the loom to the mounting bracket and turn clockwise to lock the alarm
  6. If you hove any question on installation, please contact your retailer.

WARNING: The installation instructions must be followed strictly in case of any injury.
HATHEPHS CS01 Smoke Monoxide Detector Alarm - Product
profile1 How to Power up & off the device
The device is turned off by default before leaving the factory. Before the device can be used normally, the product must be activated.
Power UP: Press the test button for over 10 seconds. When the red LED indicator lights up, release the test button. The alarm will power up and can work normally.
Power Off: If you want to power off the device, press the test button for over 10 seconds. When the red LED indicator blinks twice, release the test button. The alarm will be powered off and work will be suspended.

Test your Alarm
The Test/ Silence button is the entire top cover. Test the unit to ensure proper operation by pressing the cover; the alarm will sound if the unit is working well. If there are no sounds, you can refer to the “Troubleshooting” section for  solutions.

CAUTION:

  1. DO NOT test your alarm using an open flame. This may damage the smoke alarm, or ignite combustible materials and start a structural fire.
  2. DO NOT stand close to the alarm when the alarm is sounding. Exposure at close range may be harmful to your earing, so step away when testing.
  3. Weekly Test: test this smoke alarm once a week.

LED and Buzzer Indicators

Status LED Indicator Audible Alarm
Normal Green LED flashes every 60 seconds None
Test 2 sets of 3 red flashes followed by 2 sets of 4 red flashes. 2

sets of 3 long beeps followed by 2 sets of quick beeps.
Alarm| Unit detects smoke| Red LED flashes 3 times every 3 seconds.| 3 long beeps every
3 seconds.
Unit detects carbon monoxide| Red LED flashes 4 times every 4 seconds.| 4 quick beeps every
4 seconds.
Hush Mode| Red LED flashes once every 8 seconds| None
Low Battery| Red LED flashes once every 60 seconds| 1 beep every 60 seconds
Malfunction| Red LED flashes once every 40 seconds| 1 beep every 40 seconds

Silence Mode
During the unit is alarming, you can push the test button, it will be paused the unit alarming for approx. 10 minutes. The red LED will flash once every 8 seconds, it indicates the smoke alarm device is running into the silence mode. The  silence feature is to be used only when a known alarm condition, such as smoke from cooking activates the alarm. The smoke alarm device will automatically reset after approximately 1 0 minutes, if after this period, particles of  combustion are still present, the alarm will sound again.
CAUTION.
Before using the alarm’s hush feature, identify the source of the smoke/carbon monoxide and be certain a safe condition exists.

Maintenance and Cleaning

There are a few simple steps you need do to keep it working properly.

  1. Test the alarm once a week.
  2. Clean the alarm surface with a soft brush or cloth every month.
  3. Do not paint the alarm. Paint will seal the vents and interfere with the sensor’s ability to detect smoke.
  4. Never attempt to disassemble the alarm to clean inside. This will In addition to weekly testing, the alarm requires periodic cleaning to remove dust, dirt, and debris.

Clean the alarm at least once a month to remove dust, dirt, or debris.
Use a vacuum cleaner with the soft brush, vacuum all sides and covers of smoke alarm device.
If there is a defective battery or other failures, you can refer to “Trouble shooting” for solution, if there are still failures during warranty, you can return to your retailer.
IMPORTANT: Do not attempt to remove the cover to clean inside. This will void warranty.

Troubleshooting

Problem Method of disposal
The alarm does not sound when testing Please check whether the alarm is power

on.
Red LED flashes and the alarm delivers one beep every 60 seconds| The Battery is low. As the battery is not replaceable, please replace the alarm as quickly as possible.
Red LED flashes and the alarm delivers one beep every 40 seconds.| 1.clean the alarm. Please refer to the “maintenance and cleaning” section.
2.the alarm is malfunctioning. Contact the retailer to replace it.
Nuisance alarms triggered intermittently or when residents are cooking, taking showers, etc.| 1.press silence button.
2.clean the alarm. Please refer to the “maintenance and cleaning,, section.
3.move the alarm to new location.

Manufacturer and Support
Shenzhen Fire Security Technology Co., Ltd
Address: Room 101, No. 1, 8th Road, Yangon Industrial Zone, Shape
Community, Singing Street, Baan District, Shenzhen, 51 2127, China
Email: hathephs@163.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals