Dasqua 1801-1010 Zero Setting Devices Instruction Manual

June 16, 2024
Dasqua

PRODUCT INSTRUCTIONS
ZERO SETTING
**DEVICE

**

ZERO Button: Short press for power on, long press 3 seconds for zero setting
in/mm Button: Short press for inch/metric conversion

FEATURES

LED display
Inductive measurement system
Response speed:3.2m/s
Auto power-off,when no use for 5 minutes Power on when the measuring face moving

SPECIFICATIONS

Resolution: 0.001mm/0.00005″
Accuracy: ±0.002mm/0.00005″
Repeatability: 0.003mm
Protection grade: IP65
Light indicating at “0”
Range: 0-3mm
3V lithium battery,life>1 year

INSTRUCTIONS

Step 1: Zero Setting

  1. Flip over the device,make the top surface of the device touch with the surface of worktable.
  2. Long press zero buttom to reset the position to 0.Dasqua 1801-1010 Zero Setting Devices - Zero Setting

Step 2:Operation

Fix the device on the worktable,conduct the cutting tools and chucks towards the measuring face until 0 point, in the meantime, the LED lights up, that means the “0” position has been set.

Dasqua 1801-1010 Zero Setting Devices - Metal cutting

WARNING THE SAFETY INFORMATION GIVEN INSIDE MUST BE READ AND UNDERSTOOD BY ANY PERSON USING, INSTALLING, REPAIRING OR MAINTAINING THESE PRODUCTS