Dasqua 1804-6771 Digital Display Angle Ruler Instruction Manual

June 1, 2024
Dasqua

Dasqua 1804-6771 Digital Display Angle Ruler

Dasqua-1804-6771-Digital-Display-Angle-Ruler-PRODUCT

Product Specifications

  • 1. Shift/Set button
  • 2. Toggle CROWN mode
  • 3. LCD screen
  • 4. Switch button for single/multiple cutting mode, switch button for actual value mode
  • 5. Function key for value retention and corner compensation
  • 6. Power button/zero button

Product Usage Instructions

Power On/Off

  • To power on the device, press the set/on button. To power off the device, press and hold the power button for 5 seconds until “OFF” is displayed.

Normal mode

  • In Normal Mode, only the current angle is displayed.

CROWN fashion

  • To enter CROWN Mode, briefly press the CROWN button. Use the NEXT/SEL button to navigate and select values ​​in this mode.

Custom Angle Setting (CUS)

  • In CROWN Mode, use the NEXT/SEL button to select CUS. Rotate the measuring panel to set the desired value, then long-press NEXT/SEL to confirm.

Measurement display

  • After setting the CROWN Mode and measuring the actual angle, use NEXT/SEL to display converted values ​​like MITER and BEVEL.

HOLD mode

  • In HOLD Mode, briefly press the HOLD/REV button to lock the display with an “H” symbol.

REV Mode

  • In REV Mode, the current correction degree is displayed.

S/M CUT fashion

  • Press to switch between NORMAL, MITER (double board mode), and S CUT (single board mode). This function is not available in CROWN and REV modes.

Frequently Asked Questions (FAQ)

Q: How do I reset the device?

A: To reset the device, press the reset button located next to the power button.

Q: Can I change the language of the display?

A: Unfortunately, the language of the display cannot be changed as it is fixed based on the device’s settings.

Please read the product instructions carefully and use the product correctly under the instruction

FUNCTION

  1. NEXT/SEL button
  2. CROWN” mode switching button
  3. LCD Screen
  4. Single/Multiple cut mode switching, actual value mode switching key
  5. Value holding and corner compensation function key
  6. Power/Zero button

FEATURES

  • Gauge system with a response speed of 39 revolutions per second.
  • CR2032 lithium battery, battery life >6 months, storage >1.5 years.
  • Protection class : IP 40
  • Low voltage alarm: The symbol is displayed for low voltage.
  • Automatically screen shuts off if no operation for 5 minutes; Automatically turn off the power if no operation for 72 hours; Press the power off buttton for 5 seconds, and “OFF” will be displayed on the screen, to turn off the power.

MAINTENANCE

  1. Do not disassemble or modify this product.
  2. For maintenance, soak a soft cloth in diluted neutral detergent and use it.
  3. The use of organic solvents may cause deformation or malfunction of the product.
  4. Dirt and grime on the stem may cause malfunction. Clean the stem with a cloth moistened with alcohol or other antirust oil.
  5. Remove the batteries when the product is not used for more than 3 months. Otherwise, the battery fluid may leak out and damage the unit.

TROUBLESHOOTING

  • If the data is displayed incorrectly, remove the battery, wait for 30s and replace a new battery.
  • LCD screen error, remove and replace the battery.

INSTRUCTION

  1. Press the set/  key to turn on the power, Tap to close the measuring arm, and zero the value before use.

  2. NORMALMode: In “NORMAL” mode, only the actual angle will be displaved.

  3. CROWN Mode: Short press the “CROWN” key to enter CROWN measurement mode, short press the “NEXT/SEL” key to toggle the blinking digit, and press and hold the “NEXT/SEL” key to select the digit. Press the “NEXT/SEL” key to select the number. If the customer has an optional “CUS” user-defined function, there will be “CUS”  and “0” options.

  4. CUS” user-defined angle setting: Short press the “CROWN” key to enter the “CROWN” measurement mode, short press the “NEXT/SEL” key to switch to make “CUS” blink, turn the measurement panel, so that the screen number to the desired value, long press “NEXT/SEL” key, the system will be the value as the user’s customized value. The system will take this value as the user’s customized value. After the setting is completed, the user-defined value cannot be queried.Dasqua-1804-6771-Digital-Display-Angle-Ruler-FIG-6

  5. After the CROWN mode is set and the actual angle is measured, press NEXT/SEL briefly to display the converted MITER” value, and then press NEXT/SEL again to display the converted “MITER” value. Press NEXT/SEL again to display the formula-converted “MITER” value. Press NEXT/SEL again to display the “BEVEL” value converted by the formula. Turn the measuring arm to update the “MITER, BEVEL” values in real time.Dasqua-1804-6771-Digital-Display-Angle-Ruler-FIG-7

  6. HOLD   mode: Press the “HOLD/REV” button briefly to display the “H” character and lock the display; press the button briefly again to disappear the “H” character and unlock the display.
    REV” mode: Press “HOLD/REV” to enter REV mode, and the screen displays the current degree of correction. Not available in “CROWN” and “S/M CUT” modes.

  7. S/M CUT mode: Short press to switch between “NORMAL”, “MITER” (dual board mode), and “S-CUT” (single board mode). (Dual board mode), “S-CUT” (Single board mode). This button has no effect in “CROWN” mode and REV” mode. Key has no effect in “CROWN” mode and “REV” mode.

Note Even though you have a high-quality product, same as with any other electrical product, certain caveats have to be noted: Avoid contact with liquids and magnetic fields. Do not expose the product to sunlight and do not disassemble the product.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals