Features

  • 8 channel actuator in a compact size
  • Suitable for various and mixed applications
  • For AX, C-load, capacitive & inductive of loads
  • Program via ETS5.0 software
  • Manual control via Push button
  • Programmable various time and scene function
  • 3 years warranty

Applications

  • Building Automation
  • Lighting switch
  • Shutter/Blind control
  • Heating control
  • Ventilation function

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

The KNX actuator is a 8 channel device with high quality independent latching relay for switch, shutter or any possible mixed applications. The compact design with 4 units (72 mm) wide modular makes it suitable for installation in the distribution board on 35 mm mounting rails in the EIB / KNX application. The connection to the KNX bus is implemented via a bus connection terminal.The switching relays are particularly suitable for switching ohmic loads, capacitive loads, for instance LED drivers and inductive loads as well as motors in shutter or blind applications.The actuator are powered via the EIB/ KNX and do not require any additional power supply.

Model Encoding

Type Function Note
Blank 8 channel actuator, 16A per channel ln stock
-10 8 channel actuator, 10A per channel ln stock

SPECIFICATION

ORDER NO. KAA-8R-16 KAA-8R-10
SUPPLY SAFETY MODEL NO. KAA-8R
KNX BUS VOLTAGE 21~31V
CURRENT CONSUMPTION <6mA
POWER CONSUMPTION <180mW
Nr. OF SWITCHING OUTPUT 8
Nr. OF SHUTTER OUTPUT 4
OUTPUT TYPE Independent, potential-free bistable(latching) relay
OUTPUT SWITCHING RATINGS VOLTAGE 230VAC@50Hz
CURRENT OHMIC LOAD 16A
CAPACITIVE LOAD 220μF(See Note.2) 220μF(See Note.2)
MAX. INRUSH CURRENT 800A(max. 200μs),165A(max. 20ms) 400A(max.

200μs),80A(max. 20ms)
B S E N/EN60947-4- 1 AC1(CO S θ =0.8 )| 16A| 10A
B S EN/EN60947-4- 1 AC3(CO S θ =0.45 )| 8A| 5A
B S EN/EN60947-4- 1 AC5a(CO S θ =0.45 )| 8A| 8A
BS EN/EN60947-4-1 AC5b| 16A| 10A
MAX. TOTAL CURRENT OF THE ACTUATOR| 80A| 56A
OUTPUT SERVICE LIFE| MECHANICAL SERVICE LIFE| >10⁶
ELECTRICAL ENDURANCE BS EN/EN60669-1 19.1| 10⁴ (See Note.2)| 410⁴ (See Note.2)
BS EN/EN60669-1 19.2 , FLOURSCENT LAMP(AX)| 10⁴(See Note.2)| 10⁴ (See Note.2)
OPERATING & **DISPLAY| PROGRAMMING BUTTON/LED| Program the individual address
MANUAL BUTTON/LED| Manual control and indication
ENVIRONMENT| WORKING TEMP.| -30 ~ +45℃(3K5)
STORAGE TEMP.| -35 ~ +70℃
WORKING HUMIDITY| 10 ~ 95% RH non-condensing
PROTECTION CLASS| Ⅱ, According to BS EN/EN61140
OVER VOLTAGE CATEGORY| Ⅲ, According to BS EN/EN60664-1
POLLUTION DEGREE| 2, According to BS EN/EN60664-1
DEGREE OF PROTECTION| IP20,According to BS EN/EN60529
SAFETY & **EMC| SAFETY STANDARDS| BS EN/EN50491-3, BS EN/EN60669-1, BS EN/EN60669-2-1, BS EN/EN60669-2-5(See Note.2), EAC TP TC 004 approved
EMC EMISSION| Compliance to BS EN/EN50491-5-1,-2,-3, BS EN/EN50090-2-2, BS EN/EN60669-2-1, BS EN/EN60669-2-5, BS EN/EN63044-5-1,-2,-3(See Note.2), EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN50491-5-1,-2,-3, BS EN/EN50090-2-2, BS EN/EN60669-2-1, BS EN/EN60669-2-5, BS EN/EN63044-5-1,-2,-3(See Note.2), EAC TP TC 020
CONNECTIONS| SCREW TERMINAL| 0.5 – 4.0mm² solid core 0.5 – 2.5mm² finely stranded
KNX BUS CONNECTION TERMINAL| 0.8mmψ, solid core
OTHERS| MTBF| 605.5K hrs min.
Telcordia SR-332 (Bellcore) ; 493.1K hrs min.
MIL-HDBK-217F (25℃)
DIMENSION| 72
9057mm (WH*D)
MOUNTING WIDTH IN UNITS| 4
DIN RAIL MOUNTING| 35mm mounting rail according to DIN BS EN/EN60715
PACKING| 0.312Kg ; 48pcs/16Kg/1.02CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Notified Body test report is provided.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

Mechanical Specification

Max. output load per channel

Maximum load KAA-8R KAA-8R-10
Resistive load or heater 3680W 2300W
LED driver refer to table below refer to table below
Incandescent lamps 2300W 2300W
Halogen lamps 230V 2300W 2300W
Halogen lamps, electronic transformer 1300W 1300W
Fluorescent lamps, not compensated 2000W 2000W
Fluorescent lamps, parallel comp. 1200W 1200W
Max. number of electronic transformers 15 15
Shutter motor 600W 600W

Nr. of driver per channel

The maximum number of the MEANWELL LED driver that can be connected to each channel at 230V is shown as below

Suggested model| KAA-8R| KAA-8R-10
APC-8| 22| 22
APC-12| 11| 11
APC-16| 18| 18
APC-25| 11| 11
APC-35| 11| 11
APC-8E| 22| 22
APC-12E| 18| 18
APC-16E| 15| 15
APV-8| 22| 22
APV-12| 11| 11
APV-16| 18| 18
APV-25| 11| 11
APV-35| 11| 11
APV-8E| 22| 22
APV-12E| 18| 18
APV-16E| 15| 15
LCM-25| 25| 25
LCM-40| 25| 25
LCM-60| 25| 25
LCM-25DA| 25| 25
LCM-40DA| 25| 25
LCM-60DA| 25| 25
LPC-20| 11| 11
LPC-35| 9| 9
LPC-60| 8| 8
LPC-100| 7| 7
LPC-150| 13| 5
LPF-16| 18| 18
---|---|---
LPF-25| 16| 16
LPF-40| 16| 16
LPF-60| 9| 9
LPF-90| 7| 7
LPF-16D| 18| 18
LPF-25D| 16| 16
LPF-40D| 16| 16
LPF-60D| 9| 9
LPF-90D| 7| 7
LPH-18| 16| 16
LPHC-18| 16| 16
LPV-20| 11| 11
LPV-35| 9| 9
LPV-60| 8| 8
LPV-100| 7| 7
LPV-150| 8| 8
NPF-40| 10| 10
NPF-60| 10| 10
NPF-90| 8| 8
NPF-120| 8| 8
NPF-40D| 10| 10
NPF-60D| 10| 10
NPF-90D| 8| 8
NPF-120D| 8| 8
PCD-16B| 80| 80
PCD-25B| 53| 53
PCD-40B| 45| 45
PCD-60B| 26| 26
PLC-30| 23| 23
PLC-45| 23| 23
PLC-60| 23| 23
PLC-100| 13| 13
PLD-16B| 40| 40
PLD-25| 32| 32
PLD-40B| 32| 32
PLD-60B| 32| 32
PLM-12| 53| 53
PLM-25| 53| 53
PLM-40| 53| 53
PLN-20| 23| 23
PLN-30| 23| 23
PLN-45| 23| 23
PLN-60| 23| 23
PLN-100| 13| 13
PLP-30| 32| 32
PLP-45| 27| 27
PLP-60| 23| 23
PWM-40| 10| 10
PWM-60| 10| 10
PWM-90| 8| 8
PWM-120| 8| 8
HLN-40H| 10| 10
---|---|---
HLN-60H| 9| 9
HLN-80H| 7| 7
HLP-40H| 7| 7
HLP-60H| 9| 9
HLP-80H| 7| 7
CEN-60| 22| 22
CEN-75| 22| 22
CEN-100| 22| 22
CLG-60| 23| 23
CLG-100| 13| 13
CLG-150| 8| 8
ELG-75| 10| 10
ELG-100| 8| 8
ELG-150| 8| 8
ELG-75-C| 10| 10
ELG-100-C| 13| 13
ELG-150-C| 8| 8
HBG-100| 8| 8
HBG-160| 8| 8
HBG-240| 7| 7
HBG-60| 18| 18
HLG-40H| 16| 16
HLG-60H| 9| 9
HLG-80H| 7| 7
HLG-100H| 8| 8
HLG-120H| 8| 8
HLG-150H| 8| 8
HLG-185H| 8| 8
HLG-240H| 7| 5
HLG-320H| 7| 6
HLG-600H| 4| 3
HLG-60H-C| 8| 8
HLG-80H-C| 8| 8
HLG-120H-C| 10| 10
HLG-185H-C| 9| 9
HLG-240H-C| 7| 7
HLG-320H-C| 7| 6
HSG-70| 9| 9
HVG-65| 20| 20
HVG-100| 8| 8
HVG-150| 8| 8
HVG-240| 5| 5
HVG-320| 4| 4
HVGC-65| 20| 20
HVGC-100| 8| 8
HVGC-150| 8| 8
HVGC-240| 5| 5
HVGC-320| 4| 4

Configuration and Commissioning
The application program(database) can be downloaded via Online Catalogs from ETS or via https://www.meanwell.com//Upload/PDF/KNX_Application%20Database.pdf
It is also used to check the corresponding firmware version that works with database.

Typical application

Application 1: Work with non-dimmable driver

◎ Application 2:Work with shutter/blind control

Note: Check installation manual of shutter motor for wiring.
◎ Application 3: Work with Heater

Recommended Screwdriver, Wire and Torque Setting

  1. Screwdr i ver(W i dthTh i ck):S l otted screwdr i ver 2.50.4~3.5*0.6
  2. W i re:0.5~4.0mm2 so l i d core or 0.5~2.5mm2 f i ne l y stranded
  3. Torque:0.8Nm

Installation Manual
Please refer to: http://www.meanwell.com/manual.html

https://www.meanwell.com/webapp/product/search.aspx?prod=KAA- 8R&pdf=S0FBLThSLUUucGRm&a=4

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals