BEFORE FIRST USE:
To prevent any internal damage, it s very important to keep the product upright throughout their journey. Please leave it standing upright and outside the box for 24 HOURS before plugging it in. Waykar DP903B 216 Pints
Commercial Dehumidifier with Pump - partsFOR CUSTOMERS
Thank you for purchasing our dehumidifier.
Waykar wishes that our products and services can bring convenience to your work and life. We highly recommend that you keep the manual for reference if you encounter unexpected events using the unit. Please read the manual carefully to ensure the proper  use of the dehumidifier.
Our company’s dehumidifiers are widely used in family bedrooms, bath­ rooms, basements, offices, storage rooms, etc.
The dehumidifier from Waykar operates quickly and efficiently to reduce room’s humidity and bring you a healthy and comfortable life.
To Access Customer Support Faster
If there is any problem of the product, please contact Waykar Customer Service at [email protected] with your Purchase Order ID to help us address the problem faster.

Safety Instructions

For your safety, please read and keep the manual properly before or after using the unit.
Please use the product in accordance with the instructions in this manual.

  • Unplug the dehumidifier from the power source when cleaning.
  • Do not splash water into the machine or put it near places where it can be splashed.
  • Please do not place the machine near a heating device or dangerous inflammable things.
  • Do not put your fingers or any hard materials into the air inlet or outlet.
  • Do not sit on the unit.
  • Drain the water properly (manual or continuous drainage).
  • Please make sure that the drain hose is installed on a downward slope so that the water can be drained out properly.
  • Do not place the machine on uneven surfaces.
  • Do not spray water on this machine.
  • Do not spray pesticides or flammable liquid on this machine.
  • Do not put or place heavy objects on the machine or place children and pets on the unit.
  • Do not place this machine in a confined space.
  • If the power cord is damaged, please contact the manufacturer or qualified person to replace it to avoid hazards.
  • When using the laundry mode, please keep 15.75 inches; clearance between the clothes and the unit outlet, to avoid the water dripping into the dehumidifier and damaging the unit.
  • The wiring of the machine must be in accordance with national wiring regulations. The power cord should be connected to a reliable external naught wire.
  • The fixed wiring connected to the machine must be equipped with an all-pole disconnect device (air switch) with a contact distance of at least 0.12 inches.
  • The specification of the fuse: 5A/250V.
  • Atleast 39 inches distance shall be kept from the surround objects when using the unit.
  • Maintain the minimum clearance around the dehumidifier when the unit is operating as shown at the right.

Waykar DP903B 216 Pints Commercial Dehumidifier with Pump -
parts1

Parts Description

Waykar DP903B 216 Pints Commercial Dehumidifier with Pump -
parts2

Operation Instructions

1. Control PanelWaykar DP903B 216 Pints Commercial Dehumidifier with
Pump - parts3 Button Instructions

| Up
Turn up the parameters ncluding humidity level,timing or cleaning hours.
---|---
| Down
Turn down the parameters ncluding humidity level, timing or cleaning hours.
| Timer
Turn on or off the timer function or set up the timing hours.
| Power
Turn on or off the unit.
| OK
Set up the humidity, timing hours or cleaning mode, etc.
| Purge
Enable the pump.

Operation Descriptions

2. Indicators on the LCD Display

” ” lights up when turn on the dehumidifier and lights off when turn it off.
“ ” ights up when the dehumidifier has been plugged in but not turned on yet.
“ ” shows the current room humidity. When you press “ ” or “ ” button to set the target humidity , it will turn to display the previous setting value and keep blinking.
” ” ights up when the fan s running and lights off when it stops running.
“ ” flickers typically because the compressor is not kicked in. It usually happens when the dehumidifier is under the 3-minute compressor delay status, or the dehumidifier s programmed to delay-start (AUTO ON TIMER).
“ ” lights up when the setting humidity is 10%, and the dehumidifier enters into continuous mode.
“ ” flashes when the dehumidifier is defrosting. The dehumidifier will defrost when the frost accumulated on the nterior of the dehumidifier. The fan keeps running when defrosting, while the compressor is not. The dehumidifying function will cease until the frost melted. “ ” will light off when the defrosting completed, then the dehumidifier begins to dehumidify automatically.
NOTE: Frequent defrost process indicates that the room temperature s too low. Therefore, if the room temperature is lower than 60°F, please consider adding heat to promote proper drying.
” ” lights up when the pump is in good condition. It will light up once you turn on the dehumidifier. It flashes when the pump is working to drain the water out.
“ ” and “ ” will blink when the ambient humidity value is lower than or equal to the preset humidity value. After 30 seconds, the compressor and fan stop working. The dehumidifier will automatically restart when the ambient humidity exceeds the preset value.
3. Setting
Power

Press the” ” button to turn the dehumidifier on. When the dehumidifier is on, the “ ” indicator ights off, and the  indicator ights up.
Check the Room Humidity
Check the room humidity readout (“ “) on the control panel.
Set a Desired Humidity Percentage Value
Press “ ” or “ ” button to preset your desired humidity level. The humidity level can be set within a range of 10%RH(Relative Humidity) to 90%RH(Relative Humidity) in 1%RH increment. The setting humidity needs to be at east 5% lower than the room humidity. After setting the target humidity, press “ ” or wait 5 seconds to confirm.
NOTE:

  1. The dehumidifier will stop and start automatically to maintain room humidity level within a range of ±5% of the preset target humitity.
    For example, if the set humidity is 50%:
    When the detected humidity is 45%, 5% lower than the preset humidity, the dehumidifier will automatically stop and enter nto standby mode, the compressor stops working and indicators “ ” and “ ” flash.
    When detected humidity raises to 55%, 5% higher than the preset humidity, the dehumid­ifier will automatically restart.

  2. If the preset humidity is equal to or higher than the room humidity, the dehumidifier will not start.

  3. If the preset humidity level is 10%, the dehumidifier will enter continuous mode and run continuously.

Timer Setting

The “ ” function enables you to either delay AUTO-ON or delay AUTO-OFF the dehu­ midifier in the choice from 1 hour to 24 hours. Press “ ” and “ ” to adjust the timer by 1 hour increments.

  • Setting AUTO-ON timer: When the dehumidifier is off, press “ ” to set a timer to auto­ matically start the machine.
  • Setting AUTO-OFF timer: When the dehumidifier is on, press “ ” to set a timer to automatically shut down the machine.

NOTE:

  1. Before setting AUTO-ON TIMER, make sure the dehumidifier is plugged in.
  2. For AUTO-ON setting, please turn on the dehumidifier to set a desired humidity level. Otherwise, it will maintain the previous setting humidity.
  3. You can only set AUTO-ON timer when the dehumidifier is off or set AUTO-OFF timer when the mechine is on. It is not able to set both AUTO-ON and AUTO-OFF timer at the same time.
  4. The timer will ONLY function one time instead of cycling the dehumidifier on or off indefinitely.
  5. The timer function will be disabled when the dehumidifier has been powered on/off manually.
  6. Set the timer as 00, the timer function will not be activated.

Drainage Setting
During operation, it will automatically pump the water out via the drain hose when the pump reservoir is full. No need manual intervention.
Before moving the dehumidifier, press “ ” to empty the pump reservoir to avoid water spillage.
“ ” will blink when the pump is draining. The pump will stop working automatically in 40 seconds and stop blinking when the pump reservoir is almost empty.
NOTE: Please press “ ” to empty the inbuilt reservoir first to avoid water leakage while moving the dehumidifier.Waykar DP903B 216 Pints
Commercial Dehumidifier with Pump - parts4 Turn the Dehumidifier off
Press “ ” to turn the dehumidifier off. When the mechine is turned off, the “ ” indicator lights up, and the “ ” indicator lights off.
NOTE: To protect the compressor, the fan will continue to operate for 5 seconds after the dehumidifier shuts off. So please do not disconnect the power cord to force the dehumidifier to stop. Always use the “ ” button.
4. Smart Functions
3 Minutes Compressor Delay Mechanism
To avoid any damage to the dehumidifier, the unit will not start working in a 3 minutes com­ plete cycle. In other word, if you turn the dehumidifier off and then restart it immediately, the compressor will not kick in until 3 minutes later. During this period, you  can see the indi­cator flashing on the LCD screen until the compressor kicks in.
Auto Defrost
When the frost builds up on the evaporator coils, the compressor will stop working and the fan will continue to run until the frost melted. When the dehumidifier is defrosting, you can see the  indicator lights up on the LCD screen.
Auto Drainage
Thanks to the built-in pump, the dehumidifier will drain the condensation water automatically.
Auto-Restart
If the dehumidifier shuts off unexpectedly due to power outage, it will restart with the previous function settings automatically when the power resumes.
The timer function will not be retained and you need to reset it.
Temperature Protection Function
When the room temperature is higher than 113°F, the dehumidifier will automatically enter into HIGH-TEMPERATURE PROTECTION SYSTEM where the LCD screen shows “ ” and the compressor stops working.
When the room temperature is lower than 40°F, the dehumidifier will automatically enter into LOW-TEMPERATURE PROTECTION SYSTEM where the LCD screen shows “ ” and the dehumidifier stops working.

Drainage

Pump Drainage
During operation, the dehumidifier will automatically pump the water out via the drain hose when the pump reservoir is full. No need manual intervention.
Before turning on the dehumidifier, make sure the hose has been connected to the drain outlet properly. Waykar DP903B 216 Pints Commercial Dehumidifier
with Pump - parts5NOTE:
Place the unattached end n a sink, drain, bucket or outdoors – anywhere that water can drain out safely. ( Ensure there are no kinks or other obstructions that will stop the water to flow.)
If you use a bucket or other container for water collection, check it regularly to prevent overflows. The drain hose for the water pump can drain up to 15ft vertically. More than 15ft may cause water flow back to the pump and result in water leakage.
Continuous DrainageWaykar DP903B 216 Pints Commercial Dehumidifier with
Pump - parts6 NOTE:

  1. Please make sure the connections are tightly connected to avoid water leakage.
  2. The hose should be lower than the drain outlet to avoid backflow.
  3. The hose cannot be distorted or has substantial turning.

Maintenance

WARNING:
Ensure the dehumidifier is turned OFF and unplugged before cleaning or maintenance.
Machine Cleaning
Wipe the dehumidifier housing with a soft damp cloth. Do not submerge or place water on the dehumidifier or control panel. Water may damage the electronic components of the machine. Do not use chemical solvents such as benzene, alcohol, gasoline or other heavy-duty cleaners, for they may damage or deform the surface.
Filter Cleaning
It’s advised to clean the filter regularly and properly. Make sure clean the filter at least once a month.

  1. Open the panel from above and remove the filter.
  2. Clean the dust on the surface with the vacuum or flush and wash the filter with deter­ gent and place it at somewhere ventilated. Do not expose the filter to strong sunshine or dry the filter with high temperayure, or it may be distorted.
  3. Install the filter and close the panel.

Waykar DP903B 216 Pints Commercial Dehumidifier with Pump -
parts7

Storage
When the unit is not being used for a long period of time and you want to store it, please following the steps:

  1. Press the Purge Button to drain out the water that accumulates at the bottom of the pump. (The recommendation is to operate 2-3 times.)
  2. Unplug and wrap the cord with the power cord buckle.
  3. Clean the air filter.
  4. Cover the unit with a plastic bag.
  5. Store the unit upright in a cool and dry place.

Troubleshooting

When the breakdown and problems occurs on the dehumidifier, please refer to the troubleshooting part in the manual. Do not dismantle or repair the unit yourself, for improper repair may cause danger.
If a condition listed below occurs, please check the following items before calling customer service. It may save you time and expense.

Problems Analyses Solutions
Not working Dark Display Check the power cord socket and the wiring.
Defrost indicator lights up Defrost function is running, and the indicator

will light off after auto-defrost finished.
” ” indicator lights up| The unit shall not used in high-temperature conditions.
” ” indicator lights up| The unit shall not used in low-temperature conditions.
Much Noise| The unit is place at uneven surface.| Place the unit at somewhere flat and even.
The filter may be blocked.| Clean the filter.
See “Maintenance”.
The inlet or outlet may be blocked.| Keep the unit iniet or outlet away from objects.

Warning
If the dehumidifier is still not working properly as expected and the troubleshooting steps or solutions above may not resolve the issue, please shut down and unplug the dehumid­ ifier, then contact Waykar Customer Service at [email protected].

Error Codes

Error Codes Handling Method
El Replace the temperature and humidity sensor.
E2 Replace the temperature sensor.
E3 Make sure the water tank is well placed, and the WF port is properly

connected.
E4| Replace the temperature and humidity sensor.
E6| Make sure the display circuit has been connected right, and the DISPLAY port is well connected.
| No problem. The unit resumes working when unit temperature goes down.
| No problem. The unit resumes working when unit temperature goes up.

  1. If the problems persist, please turn off and unplug the dehumidifier, and contact Waykar Customer Service: [email protected].
  2. When E1, E2 and E4 fault alarm, the dehumidifier can operate normally, but some functions are disabled. The dehumidifier will automatically resume to operate after the fault is eliminated.

Special Notes

  1. When using the machine, please do not put it on a soft or uneven ground to prevent vibration and movement.
  2. Do not insert any thin rods or hard items into the machine to prevent malfunctions and dangers.
  3. Please do not put any objects on the dehumidifier.
  4. When using the machine, please keep it away from any heating furnaces, electric kettles and other heating sources.
  5. When using the machine, please close doors and windows for the optimal moisture removal effect.Waykar DP903B 216 Pints Commercial Dehumidifier with Pump - parts12
  6. Please do not put any objects around the machine. The dehumidification effect will be affected if the ventilation is bad.
  7. Please unplug the machine from the power source if you do not use it for a long time.Waykar DP903B 216 Pints Commercial Dehumidifier with Pump - parts14
  8. When cleaning the machine, please use wet cloth to wipe gently. Do not spray water on it directly.
  9. Please clean the filter every two weeks. Do not use hot water above 104°F, alcohol, gasoline or toluene.Waykar DP903B 216 Pints Commercial Dehumidifier with Pump - parts16
  10. After cleaning the filter, please do not dry it under direct sunlight to prevent it from deforming.Waykar DP903B 216 Pints Commercial Dehumidifier with Pump - parts17
  11. When using the hose to drain continuously, please place the hose horizontally and make sure it is even and not winded.Waykar DP903B 216 Pints Commercial Dehumidifier with Pump - parts18
  12. Before moving or carrying the machine around, please empty the water tank first.

Specifications

MODEL DP903B
POWER SOURCE 115V-60Hz
TOTAL INPUT CURRENT 11.3A
MOISTURE REMOVAL (65°F, 60%RH) 72 Pints/Day (34L/Day)
MOISTURE REMOVAL (80°F, 60%RH) 115 Pints/Day (54L/Day)
MOISTURE REMOVAL (86°F, 80%RH) 190 Pints/Day (90L/Day)
MOISTURE REMOVAL (95°F, 90%RH) 216 Pints/Day (102L/Day)
INPUT POWER (65°F, 60%RH) 790W
INPUT CURRENT(65°F,60%RH) 8.1A
MOTOR FLA 1.2A
MOTOR COMPRESSOR (RLA/LRA) RLA:9.4A LRA:47A
REFRGERANT R410a/650g
MAXIMUM ALLOWABLE PRESSURE 5.5MPa (800PSIG)
HIGH PRESSURE 4.0MPa (580PSIG)
LOW PRESSURE 1.7MPa (247PSIG)

If specifications are changed in the future, the product nameplate will reflect the new specifications.
The working temperature range of this machine is between 41°F(5°C) and 100°F(37.8°C).
If the room temperature is not within this range, the unit will not operate normally.
WARNING:
This product can expose you to chemicals including Styrene and its compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to: www.P65Warnings.ca.gov

Warranty & Contact Us

Warranty
Waykar offers a 12-month warranty to all of our products together with the original proof of purchase when a defect occured, including those newly purchased and unused, from Waykar or through an authorized reseller, wholly or substantially, or as a result of faulty manufacturing parts, or workmanship during the Warranty Period.
The warranty does not apply if damage s caused by other factors, including but without limitation of:
(a) Normal wear and tear;
(b)Abuse, mishandling, accident or failure to follow operating instructions;
(c) Exposure to liquid or infiltration of foreign particles;
(d) Servicing or modification of the product other than by Waykar.
There are our general terms for the warranty service, but we always encourage our customers to contact us f any ssues, regardless of warranty terms. If you are experi­ encing an issue with Waykar product, you can reach out to us at [email protected], we will dedicate our efforts to resolve it for you.
Extend Your Warranty by 1 Year
Remember to register your product on www.waykar.com within 14 days of receiving, to extend your 1-year warranty by an additional year.
Please fill out all required fields and include your Order ID, Date of Purchased if applicable.
Customer Support
If you have any questions or concerns about our product, please feel free to contact our expert support team. Waykar customer service is ready to help.
Waykar Office
805 Victory Trail Rd, Gaffney, SC 29340 USA
Email: [email protected]
Live Chat: www.waykar.com
Support Hours
24 Hours available
Please have your Order Number ready before contacting customer support.

For FAQs and more information please visit:
www.waykar.com
@Waykar
@Waykar
@Waykar
@WaykarWaykar DP903B 216 Pints Commercial Dehumidifier with Pump - QR
codehttps://www.waykar.com/
(Scan the QR Code for Live Chat)
We are expecting to see our products fulfill your life and hear your voice.
Your satisfaction means a lot to us.
Please tag us if you share a snap on your social media.
www.waykar.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

waykar User Manuals

Related Manuals