waykar PD100A Home Dehumidifier User Manual
- June 5, 2024
- waykar
Table of Contents
waykar PD100A Home Dehumidifier
FOR CUSTOMERS
Thank you for purchasing our dehumidifier.Waykar wishes that our products and services can bring convenience to your work and life. We highly recommend that you keep the manualfor reference if you encounter unexpected events using the unit.Please read the manual carefully to ensure the proper use of the dehumidifier.Our company’s dehumidifiers are widely used in family bedrooms,bathrooms, basements,offices,storagerooms,etc.The dehumidifier from Waykar operates quickly and efficiently to reduce room’s humidity and bring you a healthy and comfortable life.
To Access Customer Support Faster
If there is any problem of the product, please contact Waykar Customer Service at support@waykar.com with your purchase Order ID to help us address the problem faster.
BEFORE FIRST USE:
To prevent any internal damage, it is very important to keep refrigeration
units (like this one) upright throughout their journey. Please leave it
standing upright and outside the box for 24 HOURS before plugging it in.
Statement
The graphics and functions provided in this manual may not be the same as the
actual product. Please always refer to the actual product.
The model of the machine on the manual is for reference only.
Please check the corresponding content on this manual. This manual belongs to
the company rights.
PRECAUTIONS FOR USE
SAFETY NOTES:
For the safety, please read the manual carefully and keep the manual before
you use the product for reference. This product is only for the use of Home
Furnishing, please use this product according to the installation and
operation of this manual.
- When cleaning or storing a dehumidifier, pull out the plug.
- Do not spray water, pesticides or flammable liquids on this machine.
- Do not place the unit near the heater or flammable dangerous goods.
- Please don’t put your finger or strip the articles into the air inlet or outlet.
- The machine level should be maintained, to avoid placing the machine on uneven or sloping ground.
- The machine must not be placed in the closed narrow space.
- If you use dry clothing function, clothing should be at least 40CM above the air outlet distance, so as to avoid water droplets on the clothes into the machine, so that the machine damaged.
- The machine power wiring must be in accordance with national wiring rules, power line and external grounding reliable connection.
- When power line is damaged, must be replaced by the technical staff of the company and approved or qualification
- The fixed wiring of the machine must be equipped with an extreme speed disconnect device (air switch) with at least 3mm contact opening distance.
- Model specification of safety tube 3.15A
- When the use of objects and surrounding the machine at least need to keep a distance of 7.9inches(20cm), as shown in picture.
PARTS DESCRIPTION
Product component description
- Control panel
- Outlet
- Front cover
- Handle
- Inlet
- Continuous drain outlet
- Water tank
CONTROL INTERFACE
Button description
Power button
For control of machine switch machine, digital display and indicator light
will be extinguished when shutdown.
Setting
button
Used for setting humidity values.
Speed
button
Used to control high wind and low wind switching.
Timing
button
Used for timing viewing and setting.
OPERATION INSTRUCTION
Function setting
Humidity setting
In the start up state, press setting button to enter the set humidity status:
setting lights flashing, digital display 52 flashing and display the set
humidity value, every click, set the humidity value increasing 5%RH, set the
range of 30%~80%RH, can cycle setting.
Long press setting key can continuously set the humidity value.
Long time no keystroke operation, then exit the humidity setting state,
digital display shows environment humidity value, setting lights off.When the
humidity value is 30% RH, continuous dehumidification operation.
Timing Setting
In the shutdown state, the timer is set to start up, in the start up state,
the timer is set to the timing shutdown.
When timing function is not turn on,press timing button will enter the set
state: timing lights flashing, digital display shows setting time and
flashing, each click time increased 1 hours, setting range: 1~24 hours, cycle
set. The timing is invalid when the timer time is 00.
When the timing is effective, the digital display shows environment humidity,
timing light light up; press timing button once,the digital display can
display the remaining timing, automatically display the value of environmental
humidity after a few seconds.
Wind speed setting
In the start up state, according to the speed button, can choose high speed or
low speed.
Environmental temperature query
In the start up state, long press the timing button seconds, the digital display can display the ambient temperature, in seconds after the automatic display of environmental humidity value.
Water full protection
When the water tank is full, the machine stops and the water full light
flashing;
when the water full light is removed,the water light is put out and the
machine
can be restarted.
Defrost function
When running at a lower ambient temperature, the system will automatically determine whether there is frost, if frost will automatically defrost. Defrosting action: high wind fan operation, compressor stop Defrost display: when defrosting, defrosting lights flashing
Running instructions
Start: after fan start, delay seconds run the compressor, in the starting
state, restart after power cut, the fan directly start, but the compressor
delay 3 minutes to start.
Shutdown: immediately stop the compressor, fan delay a few seconds to stop.
(other faults or humidity is reached, fan delay tens of seconds to stop)
The compressor has 3 minutes delay protection function, that is, in the state
of power, the compressor stops for three minutes to start again.
State specification
- Shutdown state , power light off; delay start state, power light flashed; when the machine runs, the power light is on;
- When the humidity reaches the setting humidity and stops dehumidification (Humidity controlled state), the digital display and the power light flicker
- Set high wind speed, high light up; setting for low wind speed, low light up
- After the timer is effective, the timing light up, otherwise the light is out
- Defrosting light flashes when defrosting , on the contrary , it will off
- Water full light flashes when water full, on the contrary, it will off
- When the machine fails, the digital display will display the fault code
Fault code
No
| Fault code|
Fault name
---|---|---
1
| E1| Humidity sensor fault
2| E2|
Defrost temperature sensor fault
3
| E3| Environmental temperature sensor fault
4| E4|
Water full alarm
Attention:
- When the El, E2 or E4 fault, the machine continues to allow dehumidification, buzzer alarm and display fault code. Disconnect the power supply and the power is switched on again, the machine can still run dehumidification.
- When the fault occurs, the buzzer alarms seconds, and the alarm tone can be relieved by pressing any key during the alarm period.
Water tank drainage
- Before starting the machine, please ensure that the air outlet has been opened, otherwise the machine will overheat.
- Do not stop by directly unplug the power line way.
When the water tank is full, the water is full of lights flashing, and then automatically stop, at this time must empty the water tank, and correctly placed the water tank.
Empty the water tank
- Do not remove the floater in the water tank. If the floater of the water tank is removed, the water sensor will not be able to normally sense the water level, and the water will overflow from the water tank when the water is full.
- If the tank is dirty, only can be used in cold or warm water wash, do not use detergent, steel wool, chemical processing dust cloth, gasoline, benzene, thinner or other solvent treatment, otherwise it may cause damage to the tank Water Leakage.
- When the water tank is put into use, the water tank is pressed tightly by hand, and if the water tank is not put in tightness, the full water condition can not be relieved, and the machine can not run normally.
Continuous drainage
- In the need to use the external continuous drainage, use the tools such as knives or pliers to remove the plastic from the water tank continuously, and then insert the hose to realize the continuous drainage function;The outlet of water pipe should not be lower than 10cm for continuous drainage outlet, so as to ensure smooth drainage.
CLEANING AND MAINTENANCE
Warning
To avoid electric shock, the machine must be turned off before cleaning and
maintenance, and remove the power plug.
A-Fuselage clean
Wipe the body with a soft, damp cloth.
B-Filter cleaning
- Pullout the filter
- Cleaning filter: use dust collector to gently suck the dust on the filter surface. If the filter is very dirty, wipe it with warm water and detergent and completely dry
- The screen slowly put back the fuselage
C-Dehumidifier storage
If you don’t use the dehumidifier for a long time and want to store it, pay
attention to the procedure
- Empty the water in the tank
- rolls of power cord and tie well
- Clean the filter
- place the machine in a clean and dry environment
COMMON FAULTS AND SOLUTIONS
Check the information below for troubleshooting steps that will save you
time to resolve issues that may happen with the unit. The list includes most
common issues. Listed below are not result of defective unit, crafts or
materials in the unit. If all troubleshooting steps has been exhausted and
issue is still occurring, feel free to get in touch with Waykar Customer
Service to get further assistance.
Problem | Reason | Method |
---|---|---|
Dehumidifier does not work | The power cord is unplugged . | Make sure that the |
unit’s plug is inserted properly into the power outlet.
Is the Tankful indicator blinking? (The tank is full or in a wrong
position.)
| Empty the water in the water tank and then reposition the tank.
Is the room temperature above 95°F (35 °C)or below 41°F (5°C).| This product
does not apply to over hot or cold envi ronment , the machine will
automatically protection , it is a normal phenomenon.
Is the room temperature between 41°F(5 °C) and 68°F(20 °C) ?| When running
under lower ambient temperature ,the machine will automatically defrost , it
is a normal phenomenon. Wait until the defrost process finish , it will
restart dehumidifying again .
The dehumidifier is in the defrosting process.| It is normal the compressor
ceases while defrosting process .Wait until the defrost process finish , it
will restart dehumidifying again .
Does the room humidity is lower than or reach the preset humidity level? (The
room humidity has reached the preset humidity level .the dehumidifier enters
into Standby Mode and the LCD and indicators will flashing.)| Please set the
humidity 5% decrease by degrees than the room humidity or set the humidity to
30 %.
There is prevent frequent start function in the machine. Dose the machine stop
working just now?| Please wait for more than 3 minutes .
Room humidity is low.| The dehumidifier is designed to work in the humidity
range of 30% -80%.Above or below the work humidity range, it will not work.
Dehumidifier does not dry the air as it should| The air filter is dirty.|
Clean the air filter.
Is the air inlet or air outlet obstructed?| Remove the obstruction from the
air inlet or outlet.
The dehumidifier size is too small for application .| Increase the quantity of
dehumidifier. Or change a higher capacity dehumidifier.
Poor air circulation.| Please leave about 7.9inch(20cm) around the product.
Did not allow enough time to remove the moisture.| Allow enough time to remove
the moisture.
When first installed, allow at least 3-4 days to maintain the desired RH.
The room has not been sealed properly.| Check that all doors , windows and
other openings are securely closed.
Room temperature is too low, or below 41°F (5°C)(The machine will not work and
or poor dehumidify efficiency in low temperature| Please wait the temperature
rises above 5°C or higher.
The dehumidifier makes loud noise when operating| The dehumidifier is not
positioned level.| Move the machine to a horizontal position .
Is there blocking around the air inlet?
The air filter is clogged .| Clean up the dirty form the on the air outlet and
intake.
Is the filter installed correctly?| Please check whether the filter packing
bag removed and install correctly.
Dehumidifier operates continuously| Check if the dehumidifier is in CONTINUOUS
MODE.| Don ‘t set the humidity too low. Typically , 40-50% are good settings
to use.
Room humidity is too high.| Change humidity settings. Or change a higher
capacity dehumidifier.
Doors and windows are open.| Ensure that all doors , windows and other
openings are closed.
Overflow of water on floor| Hose to connector or hose connection may be
loose.| Connect the hose with the drain outlet tightly.
The water bucket has not been installed properly.| Re-install the water bucket
properly.
The water tank’s float has been stunk.| Move the float and let it can be swung
freely.
The magnet on the float has come off.| Put the magnet in right position.
Warning:
If the dehumidifier is still not working properly as expected and the
troubleshooting steps or solutions above may not resolve the issue.
Please unplug the power and shut down the dehumidifier then contact waykar
customer service support@waykar.com
SAFETY NOTE
Do not place unit on uneven surface.
Do not insert any sharp objects into air inlet/airoutlet.
Do not operate unit near radiators, kettles or any object that releases steam.
Do not operate unit near windows or doors opening to the outdoor.
Do not obstruct air inlet and outlet.
Unplug power when the unit is not in use for an extended period.
Do not spray any liquid onto unit.
Do not put heavy objects on top of unit.
Wash the air filter once every 2 weeks with cold water. (Do not use water >40 or benzene).
When draining water continuously, make sure drain hose is not tangled.
Do not place filter directly under.
Empty water tank before moving unit.
TECHNICAL PARAMETERS
MODEL | PDlO0A |
---|---|
POWER SOURCE | 120V-60Hz |
RATED POWER(95°F, 90%RH) | 200W |
RATED CURRENT(95°F, 90%RH) | 1.8A |
MOISTURE REMOVAL CAPACITY (65°F, 60%RH) | 8.4 Pints/Day(4L/Day) |
MOISTURE REMOVAL(80°F, 60%RH) | 12.3 Pints/ Day(5.8L/Day) |
MOISTURE REMOVAL(86°F, 80%RH) | 21.8 Pints/Day(l0.3L/Day) |
MOISTURE REMOVAL(95°F, 90%RH) | 29 Pints/Day(l3.7L/Day) |
INPUT POWER(65°F, 60%RH) | 125W |
INPUT CURRENT(65°F, 60%RH) | 1.2A |
IEF( 65°F, 60%RH) | 1.30 liters/kWh |
MOTOR FLA | 0.19A |
MOTOR COMPRESSOR | RLA:1.7A LRA:10.0A |
REFRIGERANT | R134a/4.4ozs(125g) |
MAXLMUM ALLOWABLE PRESSURE | 363 PSI G(2 .5 MPa) |
HIGH PRESSURE | 232 PSIG(l.6MPa) |
LOW PRESSURE | 90 PSI G(0 .62M Pa) |
Water Tank Capacity | 0.26 gal |
Dimensions | 11.22 ” 7.28 ” 18.5″ |
Weight | 2.2LB |
The Company reserves the right to change the product, the above parameters are subject to change without notice.
WARNING:
This product can expose you to chemicals including Styrene and its compounds,
which is known to the State of California to cause cancer and birth defects or
other reproductive harm. For more information go to:
www.P65Warnings.ca.gov
WARRANTY AND CONTACT US
Warranty
Waykar offers a 12-month warranty to all of our products, newly purchased and unused, from Waykar or through an authorized reseller, together with the original proof of purchase when a defect occurred, wholly or substantially, or as a result of faulty manufacturing, parts or workmanship during the Warranty Period. The warranty does not apply if damage is caused by other factors, including without limitation of:
(a) Normal wear and tear;
(b) Abuse, mishandling, accident or failure to follow operating instructions;
(c) Exposure to liquid or infiltration of foreign particles;
(d) Servicing or modification of the product other than by Waykar.
These are our general terms for the warranty service, but we always urge our customers to reach out to us with any issue, regardless of warranty terms. If you experience an issue with a Waykar product, please contact us at support@waykar.com, we will do our best to resolve it for you.
Extend Your Warranty by 1 Year
Register your product at www.waykar.com to extend
your 1-year warranty by an additional year.
*Please filled out all required fields and include your order ID, Date of Purchased if applicable.
Customer Support
If you have any questions or concerns about your product, please feel free to contact our expert support team. Waykar customer service is here to help!
Waykar Office
13211, Spring Street Baldwin Park, CA, US
Email: support@waykar.com
Live Chat: www.waykar.com
Support Hours
24 Hours available
*Please have your order number before contacting customer support.
For FAQs and more information please visit:
www.waykar.com
(Scan the QR Code for Live Chat)
We would love to see our product being used and how it makes your day!! Your support means the world, Please tag us if you share a snap on your social media.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>