RAB T8-17-48P-8TW-SD-BYP Linear Tube Ballast Bypass With MVS Sensor User Guide
- June 16, 2024
- RAB
Table of Contents
- T8-17-48P-8TW-SD-BYP Linear Tube Ballast Bypass With MVS Sensor
- Product Features
- Safety Information
- Installing your Lightcloud Blue Lamp
- Sensor Coverage
- Controlling your Lightcloud Blue Device
- Setting Device to Pairing Mode
- Functionality
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Welcome
Lightcloud
Linear T8 Tube Ballast Bypass
with MVS Sensor T8-17-48P-8TW-SD-BYP/LCBS/MVS
WE’RE HERE TO HELP:
1(844) LIGHTCLOUD
1(844) 544-4825
T8-17-48P-8TW-SD-BYP Linear Tube Ballast Bypass With MVS Sensor
Hello
Lightcloud Blue is a Bluetooth mesh wireless lighting control system that
allows you to control RAB’s various compatible devices. With RAB’s patent-
pending Rapid Provisioning technology, devices can be quickly and easily
commissioned for residential and large commercial applications using the
Lightcloud Blue mobile app. Each device in a system can communicate with any
other device, eliminating the need for a Gateway or Hub and maximizing the
control system’s reach.
Product Features
Direct Connect LED, No Gateway or Hub required
Wire directly to Line Voltage, bypass the ballast
Wireless control from your mobile device
On/off and dimming
Tunable White 2700K-6500K
Wireless remote control
Create custom scenes
Sensor compatible
Schedules and automations
SmartShift™ automated circadian schedule
Catalog Number: T8-17-48P-8TW-SD-BYP/LCBS/MVS
Model Number: T8-17-48P-8TW-SD-BYP/LCBS/MVS
Electrical: 17W, 2100lm, 120-277Vac, 50/60Hz
Construction: Lamp Base: G13
Retrofit application includes these items: Installation Instructions, LED
Lamps (Max. 4), Luminaire Marking Labels.
Safety Information
- WARNING – Risk of fire or electric shock. LED Rettofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
- WARNING – Risk of fire or electric shock. Install this kit only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
- WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
- WARNING – To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing shunted bi-pin lampholders. Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/IS. For more information, contact the LED luminaire retrofit kit manufacturer.
- Not suitable for use with dimmers and sensors unless specifically designed for RAB Lightcloud Blue lamps.
- This device is not intended for use with emergency exits.
- Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when connected to a standard (Incandescent) dimmer or dimming control.
- Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
- Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.
- The retrofit kit is accepted as a component of a luminaire where the suitability of the combination shall be determined by authorities having jurisdiction. Product must be installed by a qualified electrician in accordance with the applicable and appropriate electrical codes. The installation guide does not supersede local or national regulations for electrical installations.
- Installers should examine all parts that are not intended to be replaced by the retrofit kit for damage and replace any damaged parts prior to installation of the retrofit kit.
- Only dimmed by wireless control.
- Retrofit application includes these items: Installation Instructions, LED Lamps (Max. 4), Luminaire Marking Labels.
- TYPE B LAMP – Intended for operation in luminaires with traditional fluorescent-type lampholders wired directly to the branch circuit. This includes both factory-wired luminaires as well as those converted for this purpose under a retrofit program.
- CAUTION – RISK OF ELECTRIC SHOCK. Do not use if outer lamp envelope is damaged or broken. (For glass tube)
Installing your Lightcloud Blue Lamp
- Turn off power
• Place the wall switch in the off position.
• Turn off the main power at the breaker panel or remove the fuse from the fuse box.
1.a Find a suitable location
• Lightcloud Blue devices should be positioned within 60 ft. of each other.
• Building materials such as brick, concrete and steel construction may
require additional Lightcloud Blue devices to extend around an obstruction.
-
Remove lens or diffuser (/fapplicable)
-
Remove existing fluorescent lamps from the luminaire (Fig. 1)
-
Wire LED T8 directly to line voltage. Use the below wiring diagram based on current ballast wiring configuration for guidance.
Note: The ballast wiring represents typical configuration.
The actual ballast wiring varies according to ballast model.
It is not needed to change socket (ifin good condition) to operate double ended lamps, regardless of the type of sockets. Please make sure one side of fixture is connected to Live (L) and the other side to Neutral (N).
For retrofit luminaire with more than 1 lamp, please make sure only one T8-17 -48P-8TW-SD-BYP/LCBS/MVS tube sensor is enabled, others are disabled via Lightcloud Blue App configuration. We recommend to use one T8-17-48P-8TW-SD- BYP/LCBS/MVS and others LCBT8-18-48P-8TW-SD-BYP-SS tubes combination.
This product is not recommend to use in metal grille luminaire, which will impact the sensor performance.
4.a Single-ended wiring
CAUTION: Use only non-shunted lampholders for single-ended wiring installation.
Do not perform single-ended wiring installation of product in a fixture with shunted lampholders (found in all fixtures using instant start ballasts). lf the existing lampholders are shunted, please refer double-ended wiring installations below. Make new connections directly to lampholder terminal as shown.
Retrofit luminaire with 1 lamp
Program Start or Rapid Start
The Minimum distance between two luminaires is 80cm.
Retrofit luminaire with 2 lamps
Program Start or Rapid Start
Retrofit luminaire with 3 lamps
Program Start or Rapid Start
Retrofit luminaire with 4 lamps
Program Start or Rapid Start
4.b Double-ended wiring
Retrofit luminaire with 1 lamp
Instant Start
Program Start or Rapid Start
Retrofit luminaire with 2 lamps
Instant Start
Program Start or Rapid Start
Retrofit luminaire with 3 lamps
Instant Start
Program Start or Rapid Start
Minimum lamp compartment dimensions
MINIMUM LAMP COMPARTMENT DIMENSIONS
Lamp compartment of luminaire
overall dimensions, (Length x Width x Height)| Maximum lamps in luminaire|
Lamp side-to-side spacing
123 x 51 x 12 (cm)
(4.84 x 2.01 x 0.47 (inch))| 4| 8.5 (cm)
(0.33 (inch))
5. Bring LED lamp to luminaire and insert lamp pins into luminaire lamp holders.
Rotate LED lamp until lamp locks in place. Ensure that the LED lamp front
points away from the back of the luminaire. (Fig.2)
- Place lens or diffuser back in place (if applicable)
*For more in-depth wiring diagrams for specific ballast types and number of lamps please visit rablighting.com
Sensor Coverage
Sensor settings can be configured using the Lightcloud Blue mobile app.
Controlling your Lightcloud Blue Device
-
Confirm your device is powered on.
After installed, turn the power on and the lamp will enter pairing mode automatically if it has not already been paired. Once the lamp has been paired, it will indicate by flashing on and off 5 times and then dim to 30% brightness. -
Download the Lightcloud Blue app from the Apple® App Store or Google® Play store.
-
Launch the App and create an account.
-
Tap the “add device” icon in the app to start connecting devices.
-
Follow the remaining steps in the app. Create areas, groups, and scenes to organize and control your devices.
-
You’re all set!
Setting Device to Pairing Mode
If your Lightcloud Blue lamp is already paired, you can reset it by using the below methods.
Method 1: Delete from App
Open the app and access the device settings for the paired device.
Be sure that the lamp is online and select “Delete”.
Method 2: Manual
Power the lamp off and on 5 times consecutively. Do not allow less than 1
second and more than 3 seconds to elapse between switching. The lamp will
flash 3 times, then reset to 100% brightness at default CCT.
Method 3: Rapid Reset Tool
The rapid reset process must be done by professional electricians qualified by
RAB. Reach out to your RAB sales manager to request a Rapid Reset Tool. The
tool simply needs to be placed directly on the small Lightcloud logo on
downlight for 2 seconds. The downlight will flash 3 times, then reset to 100%
brightness at default CCT.
Functionality
Configuration
All configuration of Lightcloud Blue products may be performed using the
Lightcloud Blue app.
Emergency default
If communication is lost, the Lightcloud Blue lamps may fall back to a
specific state, such as turning the Lightcloud Blue lamps on.
WE’RE HERE TO HELP:
1 844-544-4825
support@lightcloud.com
[ Warning: Any wires not in use must be capped off or otherwise insulated. ]
FCC Information:
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: 1. This device may not cause harmful
interference, and 2. This device must accept any interference received,
including interference that may cause undesired operation.
Note: This device has been tested and found to comply with the limits for
Class B digital devices pursuant to Part 15 Subpart B, of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential environ ment. This equipment generates, uses,
and can radiate radio frequency energy, and if not installed and used in
accordance with the instruction manual, may cause harmful interference to
radio communications. However, there is no guarantee that inter ference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try and correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To comply with the FCC’s RF exposure limits for general population /
uncontrolled exposure, this transmitter must be installed to provide a
separation distance of at least 20 cm from all persons and must not be co-
located or operating in conjunction with any other antenna or transmitter.
The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment.
Such modifications could void the user’s authority to operate the equipment.
CAUTION: Changes or modifications to this equipment not expressly approved by RAB Lighting may void the user’s authority to operate this equipment.
Lightcloud
Lightcloud Blue is a Bluetooth mesh wireless lighting control system that allows you to control RAB’s various compatible devices. With RAB’s patent- pending Rapid Provisioning technology, devices can be quickly and easily commissioned for residential and large commercial applications using the Lightcloud Blue mobile app. Each device in a system can communicate with any other device, eliminating the need for a Gateway or Hub and maximizing the control system’s reach. Learn more at www.rablighting.com
1(844) LIGHTCLOUD
1(844) 544-4825
©2023 RAB LIGHTING Inc.
Made in China
Pat. rablighting.com/ip
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>