EPH Controls RFCP-RFCA RF Cylinder Thermostat Instruction Manual
- June 16, 2024
- EPH CONTROLS
Table of Contents
EPH Controls RFCP-RFCA RF Cylinder Thermostat
Specifications
- Class II appliance Pollution degree 2: Resistance to voltage surge 2500V; as per EN 60730
- Internal wiring diagram for RF1: 321LN ON COM OFF L N
- If the mains voltage output is required, terminals L & 2 must be electrically linked.
- MAINS SUPPLY
Mounting
- The RF1 receiver should be wall-mounted in an area within 20 meters distance of the wireless thermostat.
- The receiver must be mounted more than 1 meter away from metal objects as this will affect communication with the thermostat.
- The receiver should also be installed at least 1 meter from any electronic devices such as radio, TV, microwave, or a wireless network adaptor.
The unit can be fitted to:
- Recessed conduit boxes
- Surface mounting boxes
Installation
- Slacken the fastening screw on the bottom of the receiver with a philips screwdriver.
- The receiver is hinged and can be opened 180 degrees. Mount the unit as described in section 2.
- Wire the unit as described in section 1. Close the receiver and tighten the fastening screw.
Button / Symbol Description
- Connect button: Manual override
- System ON (Green LED)
- Reset button
- Wireless connect indicator (Red LED)
- Wireless connect: Once the voltage has been applied this button may be pressed to initialize the pairing process with the wireless thermostat.
- Once pressed the red LED will begin to flash.
- Manual override: This button will manually override the system.
- Wireless connect indicator: This LED will flash on receiving wireless signals.
If it is constantly ON, the RF1 receiver has been disconnected from the wireless thermostat.
Resetting the RF1 Receiver
- Press the RESET button located on the side of the receiver.
- Within 2 seconds, press the connect button. The RF1 receiver is now reset.
To Connect the RF1 Receiver to an RFCA Thermostat
- The wireless connect LED will be constantly red once power has been applied.
- Press the button on the RF1 receiver. Connect
- Both the red and green LED on the RF1 will begin to flash.
- On the RFCA thermostat, press the button on the bottom of the thermostat, the front housing will detach from the baseplate.
- Press the CODE button on the printed circuit board. When r1 appears on the screen, press the hand wheel once.
- The thermostat is now connected to the RF1 receiver.
To Disconnect the RFCA Thermostat from an RF1 Receiver
- On the RF1 receiver, press the reset button on the right side of the housing. Within 2 seconds, press the connect button. The RF1 receiver is now disconnected from the RFCA thermostat.
- On the RFCA thermostat, press the button on the bottom of the thermostat, the front housing will detach from the baseplate. Press the RESET button on the printed circuit board. NO will flash on the screen.
- Rotate the hand wheel clockwise until YES appears on the screen. Press the hand wheel once to confirm the setting. The thermostat is now disconnected from the receiver.
FAQ
Q: How far can the RF1 receiver be from the wireless thermostat?
- A: The RF1 receiver should be mounted within 20 meters distance of the wireless thermostat.
Q: Can the RF1 receiver be mounted near metal objects?
- A: No, the receiver must be mounted more than 1 metre away from metal objects as this will affect communication with the thermostat.
Q: Can the RF1 receiver be installed near electronic devices?
- A: No, the receiver should be installed at least 1 meter from any electronic devices such as radio, TV, microwave or wireless network adaptor.
- Important: Keep this document Prior to operation, it is necessary to complete all required settings described in this section.
Specifications & wiring
- Power Supply: 230 Vac 50Hz
- Contact Rating: 250 Vac 10(3) A
- Ambient Temp: 0~50°C
- Class I appliance
- Pollution degree 2: Resistance to
- voltage surge 2500V; as per EN 60730
- Internal wiring diagram for RF1
- If the mains voltage output is required, terminals L & 2 must be electrically linked.
Mounting
- The RF1 receiver should be wall-mounted in an area within 20 meters distance of the wireless thermostat.
- The receiver must be mounted more than 1 meter away from metal objects as this will affect communication with the thermostat.
- The receiver should also be installed at least 1 meter from any electronic devices such as radio, TV, microwave or wireless network adaptor.
The unit can be fitted to:
- Recessed conduit boxes
- Surface mounting boxes
Installation
- Slacken the fastening screw on the bottom of the receiver with a Philips screwdriver.
- The receiver is hinged and can be opened 180 degrees. Mount the unit as described in section 2. Wire the unit as described in section 1. Close the receiver and tighten the fastening screw.
Button/symbol description
CAUTION!
- Before commencing any work on the electrical connections, you must first disconnect the device from the mains. None of the 230V connections must be live until the installation has been completed and the housing is closed.
- Only qualified electricians or authorized service staff are permitted to open the terminal box.
- Some parts carry mains voltage behind the cover.
- The terminal box must not be left unsupervised when open. (Prevent non-specialists and especially children from gaining access to it.)
- Ensure that this wireless-enabled receiver is installed 1 meter from any metallic object, television, radio, or wireless internet transmitter.
- Wireless connect: Once voltage has been applied this button may be pressed to initialize the pairing process with the wireless thermostat. Once pressed the red LED will begin to flash.
- Manual override: This button will manually override the system.
- Wireless connect indicator: This LED will flash on receiving wireless signals.
- If it is constantly ON, the RF1 receiver has been disconnected from the wireless thermostat.
Resetting the RF1 receiver
- Press the RESET button located on the side of the receiver. Within 2 seconds, press press the connect button. The RF1 receiver is now reset.
To connect the RF1 receiver to an RFCA thermostat
- The wireless connect LED will be constantly red once power has been applied.
- Press the button on the RF1 receiver.
- Both the red and green LED on the RF1 will begin to flash.
- On the RFCA thermostat, press the button on the bottom of the thermostat, the front housing will detach from the baseplate.
- Press the CODE button on the printed circuit board.
- When r1 appears on the screen, press the hand wheel once.
- The thermostat is now connected to the RF1 receiver.
To disconnect the RFCA thermostat from an RF1 receiver
On the RF1 receiver
- Press the reset button on the right side of the housing.
- Within 2 seconds, press the connect button.
- The RF1 receiver is now disconnected from the RFCA thermostat.
On the RFCA thermostat
- Press the button on the bottom of the thermostat, and the front housing will detach from the baseplate.
- Press the RESET button on the printed circuit board. “NO” will flash on the screen.
- Rotate the hand wheel clockwise until “YES” appears on the screen.
- Press the hand wheel once to confirm the setting.
- The thermostat is now disconnected from the receiver.
- EPH Controls Irelandtechnical@ephcontrols.com
- www.ephcontrols.com
- EPH Controls UKtechnical@ephcontrols.co.uk
- www.ephcontrols.co.uk
Documents / Resources
| EPH
Controls RFCP-RFCA RF Cylinder
Thermostat
[pdf] Instruction Manual
RFCP-RFCA RF Cylinder Thermostat, RFCP-RFCA RF, Cylinder Thermostat,
Thermostat
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>