EPH CONTROLS R37V2 3 Zone Programmer User Guide
Installation Instructions
Factory Default Settings
Specifications
LCD Display
- Displays current time.
- Displays current day of the week.
- Displays when frost protection is activated.
- Displays when keypad is locked.
- Displays current date.
- Displays zone title.
- Displays current mode.
Button Description
Wiring Diagram
Mounting & Installation
Caution!
- Installation and connection should only be carried out by a qualified person.
- Only qualified electricians or authorised service staff are permitted to open the programmer.
- If the programmer is used in a way not specified by the manufacturer, its safety may be impaired.
- Prior to setting the programmer, it is necessary to complete all required settings described in this section.
- Before commencing installation, the programmer must be first disconnected from the mains.
This programmer can be surface mounted or mounted to a recessed conduit box.
-
Remove the programmer from its packaging.
-
Choose a mounting location for the programmer:
– Mount the programmer 1.5 metres above the floor level.
– Prevent direct exposure to sunlight or other heating / cooling sources. -
Use a philips screwdriver to loosen the screws of the backplate on the bottom of the programmer. The programmer is lifted upwards from the bottom and removed from the backplate.
(See Diagram 3 on Page 7) -
Screw the backplate onto a recessed conduit box or directly to the surface.
-
Wire the backplate as per the wiring diagram on page 6.
-
Sit the programmer onto the backplate making sure the programmer pins and the backplate contacts are making a sound connection, push the programmer flush to the surface and tighten the screws of the backplate from the bottom. (See Diagram 6 on Page 7)
Operating Instructions
Quick introduction to your R37V2 programmer:
The R37V2 programmer will be used to control three separate zones in your
central heating system.
Each zone can be independently operated and programmed to suit your needs.
Each zone has up to three daily heating programs called P1, P2 and P3. See
Page 13 for instructions on how to adjust the program settings.
On the LCD screen of your programmer you will see three separate sections, one
to represent each zone.
Within these sections you can see what mode the zone is currently in.
When in the AUTO mode, it will show when the zone is next programmed to be
switched ON or OFF.
For `Mode Selection’ please see page 11 for further explanation.
When the zone is ON, you will see the red LED for that zone light up. This
indicates that power is being sent from the programmer on this zone.
Mode Selection
AUTO
There are four modes available for selection.
AUTO The zone operates up to three ‘ON/OFF’ periods per day (P1, P2, P3).
ALL DAY The zone operates one ‘ON/OFF’ period per day. This operates from the
past ‘ON’ time to the third ’OFF’ time.
ON The zone is permanently ON.
OFF The zone is permanently OFF.
Press Select to change between AUTO, ALL DAY, ON & OFF.
The current mode will be shown on the screen under the specie zone.
The Select are found under the front cover. Each zone has its own Select .
Programming Modes
This programmer has the following programming modes. 5/2 Day mode Programming
Monday to Friday as one block and
5/2 Day mode Programming Monday to Friday as one block and Saturday and Sunday
as a 2nd block.
7 Day mode Programming all 7 days individually.
24 Hour mode Programming all 7 days as one block.
Factory Program Settings 5/2d
Adjust the Program Setting in 5/2 Day Mode
Reviewing the Program Settings
Press PROG .
Press OK to scroll through the periods for the individual day (block of days).
Press Select to jump to the next day (block of days).
Press MENU to return to normal operation.
You must press the specific Select to review the schedule for that zone.
Boost Function
Each zone can be boosted for 30 minutes, 1, 2 or 3 hours while the zone is in
the AUTO, ALL DAY & OFF mode. Press Boost 1, 2, 3 or 4 times, to apply the
desired BOOST period to the Zone. When a Boost is pressed there is a 5 second
delay before activation where `BOOST’ will flash on the screen, this gives the
user the time to select the desired BOOST period. To cancel a BOOST, press the
respective Boost again. When a BOOST period has ended or has been cancelled,
the Zone will return to the mode that was previously active prior to the
BOOST.
Note: A BOOST cannot be applied while in the ON or Holiday Mode.
Advance Function
When a zone is in the AUTO or ALLDAY mode, the Advance function allows the
user to bring the zone or zones forward to the next switching time. If the
zone is currently timed to be OFF and ADV is pressed, the zone will be
switched ON until the end of the next switching time. If the zone is currently
timed to be ON and ADV is pressed, the zone will be switched OFF until the
start of the next switching time. Press ADV . Zone1, Zone 2, Zone 3 and Zone 4
will begin to flash. Press the appropriate Select . The zone will display
ADVANCE ON’ or
ADVANCE OFF’ until the end of the next switching time. Zone 1
will stop flashing and enter Advance mode. Zone 2 and Zone 3 will remain
flashing. Repeat this process with Zone 2 and Zone 3 if required. Press OK To
cancel an ADVANCE, press the appropriate Select . When an ADVANCE period has
ended or has been cancelled, the zone will return to the mode that was
previously active prior to the ADVANCE.
Menu
This menu allows the user to adjust additional functions. To access the menu, press MENU .
P01 Setting the Date, Time and the Programming Mode DST ON
Note: Please see page 12 for descriptions of Programming Modes.
P02 Holiday Mode
P03 Frost Protection OFF
The Frost symbol will display on the screen if the user activates it in the menu.
If the ambient room temperature drops below the desired frost protection temperature, all zones of the programmer will activate and the frost symbol will flash until the frost protection temperature has been achieved.
P04 Zone Title
This menu allows the user to select different titles for each zone. The options are:
P05 PIN
This menu allows the user to put a PIN lock on the programmer. The PIN lock
will reduce the functionality of the programmer.
Set up the PIN
Copy Function
Copy function can only be used when the 7d mode is selected. (See page 16 to
select 7d mode) Press PROG to program the ON and OFF periods for the day for
the week you want to copy. Do not press OK on the P3 OFF time, leave this
period flashing. Press ADV , COPY’ will appear on the screen, with the next day of the week flashing. To add the desired schedule to this day press . To skip this day press . Press OK when the schedule has been applied to the desired days. Ensure the zone is in the
Auto’ mode for this schedule to
operate accordingly. Repeat this process for Zone 2 or Zone 3 if required.
Note: You cannot copy schedules from one zone to another, E.g. Copying Zone 1
schedule to Zone 2 is not possible.
Backlight Mode Selection ON
There are 3 backlight settings available for selection:
AUTO Backlight stays on for 10 seconds when any button is pressed.
ON Backlight is permanently On.
OFF Backlight is permanently Off.
To adjust the backlight press and hold OK for 10 seconds. `Auto’ appears on the screen. Press or to change the mode between Auto, On and Off. Press OK to confirm selection and to return to normal operation.
Locking the Keypad
Resetting the Programmer
To reset the programmer to factory settings:
Press MENU .
‘P01’ will appear on the screen.
Press until ‘P06 rESEt’ appears on the screen.
Press OK to select.
‘nO’ will begin to flash.
Press , to change from ‘nO’ to ‘YES’.
Press OK to confirm.
The programmer will restart and revert to its factory defined settings.
The time and date will not be reset.
Master Reset
To master reset the programmer to factory settings, locate the master reset button on the right-hand side underneath the programmer. (see page 5) Press the Master Reset button and release it. The screen will go blank and reboot. The programmer will restart and revert to its factory defined settings.
Service Interval OFF
The service interval gives the installer the ability to put an annual
countdown timer on the programmer. When the Service Interval is activated
`SErv’ will appear on the screen which will alert the user that their annual
boiler service is due.
For details on how to enable or disable the Service Interval, please contact
customer service.
EPH Controls IE
technical@ephcontrols.com
www.ephcontrols.com/contact-us T +353 21 471
8440WWW.ephcontrols.com
EPH Controls UK
technical@ephcontrols.co.uk
www.ephcontrols.co.uk/contact-us T +44 1933
322 072www.ephcontrols.co.uk
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>