nVent CADDY BC8P Conduit to Beam Clamp Owner’s Manual

June 16, 2024
nVent Caddy

nVent CADDY BC8P Conduit to Beam Clamp

nVent-CADDY-BC8P-Conduit-to-Beam-Clamp-product

Product Information

Specifications

  • Product Name: BC-P Conduit to Beam Clamp
  • Catalog Number: BC8P
  • Material: Spring Steel
  • Finish: nVent CADDY Armour
  • EMT Conduit Size: 1/2
  • Flange Thickness: 1/2
  • Max Torque: 20 ft lb
  • Ultimate Static Load: 25 lb

Features

  • Easy installation to beam flanges
  • Eliminates offset bending conduit

Warning

nVent products shall be installed and used only as indicated in nVent’s product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication, or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death, and/or void your warranty.

Product Usage Instructions

Step 1: Preparation

Gather the following materials:

  • BC-P Conduit to Beam Clamp (Catalog Number: BC8P)
  • 1/2 EMT Conduit
  • Tools required for installation (wrench, screwdriver, etc.)

Step 2: Inspection

Before installation, inspect the BC-P Conduit to Beam Clamp for any visible damage or defects. Do not use if the product is damaged.

Step 3: Installation

  1. Identify the beam flanges where you want to install the conduit clamp.
  2. Position the BC-P Conduit to Beam Clamp on the desired location of the beam flanges.
  3. Securely tighten the clamp using the appropriate tools to achieve a torque of 20 ft lb.
  4. Verify that the clamp is properly aligned and securely attached to the beam flanges.

Step 4: Conduit Installation

  1. Insert the 1/2 EMT Conduit into the BC-P Conduit to Beam Clamp.
  2. Route and secure the conduit according to your specific application requirements.
  3. Ensure that the conduit is properly fastened and supported along its entire length.

Step 5: Final Check

  • After installation, visually inspect the entire setup to ensure that the BC-P Conduit to Beam Clamp and the conduit are securely installed and aligned.
  • Make any necessary adjustments if required.

Maintenance

  • Regularly inspect the BC-P Conduit to Beam Clamp and the conduit for any signs of damage or wear.
  • Replace any damaged parts immediately to ensure proper functionality and safety.

Removal

  • To remove the BC-P Conduit to Beam Clamp, carefully loosen the clamp using the appropriate tools.
  • Remove the conduit from the clamp and detach the clamp from the beam flanges.

Frequently Asked Questions

  • Q: Can I use the BC-P Conduit to Beam Clamp with a different size of EMT conduit?
    • A: No, the BC-P Conduit to Beam Clamp is specifically designed for use with 1/2 EMT conduit. Using a different size may result in improper fit and compromised performance.
  • Q: What is the maximum torque required for tightening the BC-P Conduit to Beam Clamp?
    • A: The maximum torque required is 20 ft lb. Ensure that you do not exceed this torque value during installation to prevent damage to the clamp or beam flanges.
  • Q: What is the maximum static load capacity of the BC-P Conduit to Beam Clamp?
    • A: The BC-P Conduit to Beam Clamp has an ultimate static load capacity of 25 lb. Do not exceed this limit to maintain the clamp’s structural integrity.

FEATURES AND PRODUCT ATTRIBUTES

FEATURES

  • Easy installation to beam flanges
  • Eliminates offset bending conduit

PRODUCT ATTRIBUTES

  • Material: Spring Steel
  • Finish: nVent CADDY Armour
  • EMT Conduit Size: 1/2″
  • Flange Thickness: 1/2″ Max
  • Torque: 20 ft lb
  • Ultimate Static Load: 25 lb

DIAGRAMS

nVent-CADDY-BC8P-Conduit-to-Beam-Clamp-FIG-1

WARNING

nVent products shall be installed and used only as indicated in nVent’s product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty.

CONTACTS

North America

  • +1.800.753.9221
  • Option 1 – Customer Care
  • Option 2 – Technical Support

Europe

  • Netherlands: +31 800-0200135

Europe

  • Germany: 800 1890272
  • Other Countries: +31 13 5835404

APAC

  • Shanghai: + 86 21 2412 1618/19
  • Sydney: +61 2 9751 8500

Our powerful portfolio of brands:

  • CADDY
  • ERICO
  • HOFFMAN
  • RAYCHEM
  • SCHROFF
  • TRACER

nVent.com

© 2023 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners.
nVent reserves the right to change specifications without notice.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

nVent Caddy User Manuals

Related Manuals