Specification

  • Input: 125VAC 60Hz
  • Frequency: 908.42 MHz
  • Loading: 200W Incandescent 100W
  • Dimmable CFL/LED

Indoor use in dry location

Features:

  1. Z-Wave on/off + dimmer control.
  2. Grounded 3-wire power connection for safety.
  3. Remember and restore on/off status after power failure.
  4. Built-in Z-\Wave Plus signal repeater to extend network range
  5. 52 security and 800 Z-Wave chip for reliable wireless communication
  6. Work with all certificated Z-Wave controllers.7. Support Long Range.

Min brightness level setting (Refer to Parameter 11)

  1. Press the button 5 times quickly, the LED indicator flashes slowly to enter the setting “Min brightness” mode. The lamp will adjusts to the min brightness automatically.
  2. Hold the button to adjust the brightness of the bulb, select the appropriate brightness to set the min brightness.3: Press the button 5 times quickly to confirm it (the min brightness setting is completed). The LED indicator will flashes 3 times.

Max brightness level setting (Refer to Parameter 12)

  1. Press the button 10 times quickly, the LED indicator flashes slowly to enter the setting”Max brightness” mode. The lamp will adjusts to the max brightness automatically.
  2. Hold the button to adjust the brightness of the bulb, select the appropriate brightness to set the max brightness.
  3. Press the button 10 times quickly to confirm it (the max brightness setting is completed).
    The LED indicator will flashes 3 times. Remark: If the setting is not confirmed at Step 3, the setting mode will be exited after 10S.

Z-WAVE INTEROPERABILITY

This product can be included and operated in any Z-Wave network with other -Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. This Device supports Lifeline (association group 1) supporting 1 node for lifeline communication. Group 1 must be assigned the Node ID of the primary controller where unsolicited notifications will be sent.The Z-Wave controller should set this association automatically after inclusion.Lifeline association only supports the “Device Reset Locally” function.

Adding Device To Z-Wave Network for QR CODE

900115294003421093116320775447815891832722201022891400100179303078022000634286725734500256

Scan here for SmartStar inclusion Note: FULL DSK can be found on the packaging box.
Do not remove or damage them.

Z-Wave Network Configuration

Adding Device To Z-Wave Network

  1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave
  2. Once the controller is ready to add your device, press the Manual/ Program button on the smart plug 3 times quickly.

Add QR Code For LR:
The device is compatible with smartstart. SmartStart enabled products can be added to a Z- Wave network by scanning the Z-Wave QR Code found on the top of the outlet or the back of the box with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on and in the network vicinity.
Note: Z-Wave Long Range device can only support be included via SmartStart. Extract the DSK from the end device and paste it into the DSK Value in the PC Controller, make sure the “Long Range” option is ticked.
To Remove The Device

  1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z- Wave network.
  2. Once the controller is ready to remove your device, press the manual / program button on the smart plug 3 times quickly.
    The green light is on for 25 when the removal is successful.

To Return The Device To Factory Defaults
Manual: press the button twice quickly then hold a 3rd press for 10 seconds.
Host reset: Remove it from hub, the device will be restore tofactory default.
Association Group
(LED flashes twice when the configuration parameter changed.)
Support 2 groups, each group max support 5 devices Group 1lifeline Group 2 Left outlet send basic set.

Parameter Settings

This parameter can access you to choose the LED indicator to be on when the plug(light) is on/off, or LED indicator remains on/off all times.
(LED flashes 3 times when the configuration parameter changed.)

— Parameter =2, size =1byte, Default =0
Value=0 (default) LED is On when switch (light) is Off.
Value=1 — LED is On when switch (light) is On.
Value=2 — LED is always Off.
Value=3 — LED is always On.

Auto Turn-Off Timer

This parameter can access you to set a timer to make the switch turn off automatically after the switch turns on.The numberentered as value corresponds to number of minutes. Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
— Parameter =4, Size=4, Value: 0-65535(minutes);
Value=O(default) disable

Auto Turn-On Timer

This parameter can access you to set a timer to make the switch turn on automatically after the switch turned off. The numberentered as value corresponds to number of minutes. Operation:
Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
— Parameter =6, Size=4, Value: 0-65535(minutes);
Value=O(default) disable turn on the outlet

Night Light Set
it as a night light.
(LED flashes 3 times when the configuration parameter changed.)
— Parameter =7, Size=1, Default = 2
Value=1 — 10% brightness
Value=2 — 20% brightness /
Value=10 — 100% brightness

Restores state after power failure
This parameter can access you to set the switch to be on/off after power failure.
Operation: quickly press 8 times to change this parameter.
(LED flashes 3 times when the configuration parameter changed.)
Parameter=8, Size=1, Value=2(default)
Value=1 — The switch is on regardless of the state prior to power failure.
Value=2(default) memory state before power failure
This switch will be return to state prior to the power failure after power is restored.

Dimmer speed (ON/OFF Control)
This parameter can access you to set the time from maximum brightness to minimum brightness or minimum brightness to maximum brightness
(Only when turn ON/ OFF the light) Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
Parameter=9, Size=1, Default = 2
Value=0 —instant on/
Value-1— from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value=2—from 0x63 to 0x00 or from 0x00 to 0x63 need 2s /
Value-10— from 0x63 to 0x00 or from 0x00 to 0x63 need 10s

Dimmer speed (Dimmer Control)
This parameter can access you to set the time from maximum brightness to minimum brightness or minimum brightness to maximum brightness.
(Only when hold it to change the brightness or control from HUB).
Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
Parameter=10, Size=1, Default=4
Value=1—from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value-2—from 0x63 to 0x00 or from 0x00 to 0x63 need 2s /
Value=10—from 0x63 to 0x00 or from 0x00 to 0x63 need 10s

Multilevel minimum value can be set

Operation: quickly press 5 times to change this parameter.
(LED flashes 3 times when the configuration parameter changed.)
—Parameter=11, Size=1, Default = 10
Value=0 — disable
Value=1
/
Value=99

Multilevel maximum value can be set
Operation: quickly press 10 times to change this parameter.
(LED flashes 3 times when the configuration parameter changed.)
—Parameter=12, Size=1, Default =99
Value=0 — disable
Value=1
/
Value=99

Generic Device Class:

FCC / IC
This device complies with part 15 of the FCC and Industry Canada license- exempt RSS

  1. This device may not cause harmful interference,
  2. This device must accept any standard(s). Operation is subjected to the following two conditions: interference received, including interference that may cause undesired operation.

FCC NOTE: The manufacturer is not responsible for any radio or TV interference the user’s authority to operate the equipment.

  • Reorient or relocate the receiving antenna. caused by unauthorized modifications to this equipment. Such modifications could void receiver is connected.
  • Increase the separation between the equipment and receiver.
  • Consult the dealer or an experienced radio / TV technician for help.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide generates, uses and can radiate radio frequency energy and, if not installed and used in determined by turning the equipmen couraged to try to correct the reasonable protection against harmful interference in a residential installation. This equipment accordance with the instructions may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Connect the equipment into an outlet on a circuit di erent from that to which the receiver is
  • Increase the separation between the equipment and receiver. connected.
  • Consult the dealer or an experienced radio/TV technician for help.

NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide generates, uses and can radiate radio frequency energy  and, if not installed and used in determined by turning the equipmen couraged to try to correct the reasonable protection against harmful interference in a residential installation. This equipment accordance with the instructions may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  •  Connect the equipment into an outlet on a circuit di erent from that to which the receiver is
  • Increase the separation between the equipment and receiver. connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Important note : To comply with the FCC RF exposure compliance requirements, no change to the  antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s authority to operate the device.

CAUTION – PLEASE READ!
This device is intended for installation in accordance with the National Electric Code and local regulations in the United States, or the Canadian Electrical Code and local regulations in Canada If you are unsure or uncomfortable about performing this installation consult a qualified electrician.

WARNING
RISK OF FIRE / RISK OF ELECTRICAL SHOCK / RISK OF BURNS TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS PRODUCT HAS A GROUNDING TYPE PLUG THAT HAS A THIRD (GROUNDING) PIN. THIS PLUG WILL ONLY FIT INTO A GROUNDING TYPE POWER OUTLET.
IF THE PLUG DOES NOT FIT INTO THE OUTLET, CONTACT A QUALIFIED ELECTRICIAN TO INSTALL THE PROPER OUTLET. DO NOT CHANGE THE PLUG IN ANY WAY.
CONTROLLING APPLIANCES:

CAUTION : TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT

  • DO NOT EXCEED RATINGS
  • DO NOT USE TO CONTROL ANY DEVICE

WHERE UNINTENDED OPERATION COULD
CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)

MEDICAL EQUIPMENT

Please DO NOT use this switch to control Medical or Life Support equipment.
Z-Wave devices should never be used to control the On / Off status of Medical and / or Life Support equipment.

CONTROLLING APPLIANCES
Please exercise EXTREME CAUTION when using Z-Wave devices to control appliances. Reason being is because the appliance you want to control may be in a separate room and if unintentional behavior occurs (such as adevice turning on or off – either intentionally via schedules, or unintentionally via network error) this event may lead to a hazardous condition.
For these reasons, please note the following suggestions:

  1. Do not include Z-Wave devices in Groups or Scenes if they control appliances.
  2. Do not use Z-Wave devices to control electric heaters or any other appliances which may present a hazardous condition due to unattended, unintentional, or automatic power control.

RF warning for Portable device:
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals