PAPI004174-INTER5 pH Regulator Instruction Manual
- June 15, 2024
- PAPI
Table of Contents
PAPI004174-INTER5 pH Regulator
INSTALLATION DIAGRAM
-
The pH corrector container must be kept 2 metres away from any electrical device or any other chemicals. In order for acid fumes to be expelled outside the pool house, a venting system must be placed on the pH
possibly resulting in complete device failure. Personal protective equipment (glasses with side protection, whenever handling the pH corrector or the injection circuit. -
Never use hydrochloric acid, as this may lead to irreversible damage to the device and void the warranty. Only use a sulphuric acid- or alkali-based pH corrector product recommended by your professional dealer. Please note that use of a multi-acid pH corrector requires increased maintenance, and its use may also lead to premature wear of the pH circuit and void the warranty. .
-
Electronics box
-
Ballast filter
-
Peristaltic pump
-
Pool Terre (optional)
-
Probe holder
-
Injection connector
-
pH probe
-
Bracket
-
Semi-flexible tubing
ELEMENTS NOT SUPPLIED -
Electrical power supply
-
pH corrector container
-
Copper cable
-
Electrolysis cell
-
Filter
-
Ground rod
-
Heat pump
-
Filtration pump
-
Venting system
ELECTRONICS BOX
Interface
-
Command keys
-
Red LED
If lit continuously: electronics box stopped.
If flashing: AL alarm triggered. -
Screen
Default display: pH measurement. -
Green LED
If lit continuously: electronics box in operation.
If flashing: peristaltic pump running.
Switching on and off
Make a long press on the left key.
When switching on, a chaser is displayed for a few seconds, then the pH
measurement is displayed.
The pH regulation is activated automatically.
Meaning of menus
FUNCTIONALITY
Adjustment of the pH setpoint
Calibration of the pH probe
Specification of the type of pH corrector used
Specification of the pH concentration rate used
Manual injection of pH corrector
Adjustment of the pH measurement
Specification of basin volume
Adjustment of the pH setpoint
Possible settings : from 6.8 to 7.6, in steps of 0.1.
Default setting : 7.2.
- Make a long press on the right key until the message NA flashes.
- Press the up or down key x times until the message SE flashes.
- Press the right key : the flashing value is the saved setpoint.
- Select a value with the up/down keys.
- Press the right key to validate : the selected value freezes briefly, then the message SE flashes.
- Press the left key twice to return to the default display.
Calibration of the pH probe
The supplied pH probe is already calibrated. It is therefore not necessary to
calibrate the pH probe when the equipment is put into service for the first
time.
However, in order to ensure optimal pH regulation, it is imperative to
calibrate the pH probe at the start of each season when putting back into
service, and after each replacement of the probe.
-
Switch off the filtration (and therefore the electronics box).
-
Open the standard solutions pH 7 and pH 10 (use only single-use standard solutions).
-
If the probe is already installed :
a) Extract the probe from the probe holder, without disconnecting it.
b) Remove the nut from the probe holder and replace it with the plug provided.
If the probe is not yet installed : Connect the probe to the electronics box. -
Switch on the electronics box.
-
Make a long press on the right key until the message flashes.
-
Press the up or down key x times until the message flashes.
-
Press the right key to validate : the message flashes.
-
Insert the probe into the pH 7 standard solution, then wait a few minutes.
-
Press the right key : the display below appears.
Do not touch the probe during this time, and wait until you get one of the displays below. -
2 Possibilities :
The message flashes. In this case, go to step 11.
The message is displayed : calibration failed. To acknowledge this display, press the left key.
In this case, visually check the condition of the probe, then attempt the calibration again, several times if necessary. If the calibration still fails, change the probe and recalibrate. -
Insert the probe into the pH 10 standard solution, then wait a few minutes.
-
Press the right key : the display below appears.
Do not touch the probe during this time, and wait until you get one of the displays below. -
2 Possibilities :
The message is displayed briefly, then the message flashes. Calibration is complete.
The message is displayed : calibration failed. In this case, visually check the condition of the probe, then attempt the calibration again, several times if necessary. If the calibration still fails, change the probe and recalibrate.
To acknowledge these displays, press the left key twice : the default display appears.
The pH 7 and pH 10 standard solutions are for single use. To avoid handling errors, discard these solutions after use.
Specification of the type of pH corrector used
Possible settings : AC (acidic), bA (basic).
Default setting : AC
- Make a long press on the right key until the message NA flashes.
- Press the up or down key x times until the message C0 flashes.
- Press the right key : the flashing message corresponds to the type of pH corrector recorded.
- Select a type of pH corrector with the up/down keys.
- Press the right key to validate : the type of pH corrector selected freezes briefly, then the message C0 flashes.
- Press the left key twice to return to the default display.
Specification of the pH concentration rate used
Possible settings: from 5 to 55 (i.e. from 5% to 55%, in steps of 1%).
Default setting: 37
- Make a long press on the right key until the message NA flashes.
- Press the up or down key x times until the message CC flashes.
- Press the right key : the flashing value is the pH concentration rate recorded.
- Select a value with the up/down keys.
- Press the right key to validate : the selected value freezes briefly, then the message CC flashes.
- Press the left key twice to return to the default display.
Manual injection of pH corrector
This function also allows you to prime the peristaltic pump.
Possible settings of the injection duration : from 1 to 60 (i.e. from 1 s to
60 s, in steps of 1 s), then from 11 to 95 (i.e. from 1 min 10 s to 9 min 50
s, in steps of 10 s).
Setting the default injection duration : 60.
To set the injection duration and then start the injection :
-
Make a long press on the right key until the message flashes.
-
Press the right key : the default injection duration flashes (60 s).
-
Select an injection duration with the up/down keys.
-
Press the right key to validate the duration and start the injection : the injection duration is displayed in real time (time countdown).
To stop the injection before the time has elapsed, press the left or right key. -
When the injection is complete, press the left key twice to return to the default display.
Adjustment of the pH measurement
Possible settings : from 6.5 to 7.5, in steps of 0.1.
-
Make a long press on the right key until the message NA flashes.
-
Press the up or down key x times until the message Ad flashes.
-
Press the right key.
-
Select a value with the up/down keys.
-
Press the right key to validate.
-
2 Possibilities :
The message Oh is displayed briefly, then the message Ad flashes : the adjustment is complete.
The message Er is displayed briefly, then the message Ad flashes : the adjustment failed. In this case, visually check the state of the pH probe, then attempt an adjustment again, several times if necessary. If the adjustment still fails, change the pH probe and perform a pH probe calibration. -
Press the left key twice to return to the default display.
Specification of basin volume
Possible settings : by code, according to the tables below.
Basin volume | Code |
---|---|
from 0 to 1 m3 | 1 |
from 1 to 2 m3 | 2 |
from 2 to 3 m3 | 3 |
from 3 to 4 m3 | 4 |
from 4 to 5 m3 | 5 |
from 5 to 6 m3 | 6 |
from 6 to 7 m3 | 7 |
from 7 to 8 m3 | 8 |
from 8 to 9 m3 | 9 |
from 9 to 10 m3 | 10 |
Basin volume | Code |
--- | --- |
from 10 to 15 m3 | 11 |
from 15 to 20 m3 | 12 |
from 20 to 25 m3 | 13 |
from 25 to 30 m3 | 14 |
from 30 to 35 m3 | 15 |
from 35 to 40 m3 | 16 |
from 40 to 45 m3 | 17 |
from 45 to 50 m3 | 18 |
from 50 to 55 m3 | 19 |
from 55 to 60 m3 | 20 |
Basin volume | Code |
--- | --- |
from 60 to 70 m3 | 21 |
from 70 to 80 m3 | 22 |
from 80 to 90 m3 | 23 |
from 90 to 100 m3 | 24 |
from 100 to 110 m3 | 25 |
from 110 to 120 m3 | 26 |
from 120 to 130 m3 | 27 |
from 130 to 140 m3 | 28 |
from 140 to 150 m3 | 29 |
from 150 to 160 m3 | 30 |
Default setting: 20.
- Make a long press on the right key until the message NA flashes.
- Press the up or down key x times until the message CP flashes.
- Press the right key : the flashing code corresponds to the basin volume recorded.
- Select a code with the up/down keys.
- Press the right key to validate : the selected code freezes briefly, then the message CP flashes.
- Press the left key twice to return to the default display.
Alarms
Flashing display| Fault detected| Immediate automatic
action| Checks and remedies| Acknowledgment
---|---|---|---|---
pH measurement| A difference of + or – 0.5 between the pH measurement and the
pH setpoint| | Manually measure the pH with a recent test kit.
If the value obtained corresponds to the value displayed :
a) Switch off the electronics box.
b) Pour the pH corrector (acidic if the pH is too high, or basic if the pH is too low) into the basin, near the delivery nozzles, so as to obtain a pH of around 7.2.
c) Wait 30 minutes.
d) Restart the electronics box.
e) Check that the pH measured by the electronics box is approximately 7.2.
If the value obtained does not correspond to the value displayed :
Perform a pH probe calibration.
| Automatic
AL
| Succession of several unsuccessful attempts to correct the pH| pH regulation stopped| – Check that the pH corrector container is not empty. If the container is empty, replace it then perform a manual injection of pH corrector.
– Check the condition of the ballast filter and the injection connector.
– Carry out a calibration of the pH probe.
| Press the right key
GUARANTEE
Before contacting your dealer, please have the following to hand :
- your purchase invoice.
- the serial no. of the electronics unit.
- the installation date of the equipment.
- the parameters of your pool (salinity, pH, chlorine levels, water temperature, stabilizer level, pool volume, daily filtration time, etc.).
Every effort and all our technical experience has gone into designing this equipment. It has been subjected to quality controls. If, despite all the attention and expertise involved in its manufacture, you need to make use of our guarantee, it only applies to free
Guarantee period (proven by date of invoice)
Electronics box: 2 years.
pH probe: depending on model.
Repairs and spare parts: 3 months.
The periods indicated above correspond to standard guarantees. However, these
can vary depending on the country of installation and the distribution
network.
Scope of the guarantee
The warranty covers all parts, with the exception of wearing parts that must
be replaced regularly.
The equipment is warranted against manufacturing defects within the strict
limitations of normal use.
Never use hydrochloric acid, as this may lead to irreversible damage to the
device and void the warranty. Only use a sulphuric acid- or alkali-based pH
corrector product recommended by your professional dealer. Please note that
use of a multi-acid pH corrector requires increased maintenance, and its use
may also lead to premature wear of the pH circuit and void the warranty.
After-sales services
All repairs will be performed in the workshop.
Shipping costs in both directions are at the user’s own expense.
Any downtime and loss of use of a device in the event of repairs shall not
give rise to any claim for compensation.
In all cases, the equipment is always sent at the user’s own risk. Before
taking delivery, the user must ensure that it is in perfect condition and, if
necessary, write down any reservations on the shipping note of the carrier.
Confirm with the carrier within 72 hours by recorded letter with
acknowledgment of receipt.
Replacement under guarantee shall in no case extend the original guarantee
period.
Guarantee application limit
In order to improve the quality of their products, the manufacturer reserves
the right to modify the characteristics of the products at any time without
notice.
This documentation is provided for information purposes only and is not
contractually binding with respect to third parties.
Installation, maintenance and, more generally, any servicing of the manufacturer’s products should only be performed by professionals. This work must also be carried out in accordance with the current standards in the country of installation at the time of installation. The use of any parts other than original parts voids the guarantee ipso facto for the entire equipment.
The following are excluded from the guarantee :
- Equipment and labour provided by third parties in installing the device.
- Damage caused by installation not in compliance with the instructions.
- Problems caused by modifications, accidents, misuse, negligence of professionals or end users, unauthorised repairs, fire, floods, lightning, freezing, armed conflict or any other force-majeure events.
Any equipment damaged due to non-compliance with the instructions regarding
safety, installation, use and maintenance contained in this documentation will
not be covered by the guarantee.
Every year, we make improvements to our products and software. These new
versions are compatible with previous models. The new versions of hardware and
software cannot be added to earlier models under the guarantee.
Implementation of the guarantee
For more information regarding this guarantee, contact your dealer or our
After-Sales Service. All requests must be accompanied by a copy of the
purchase invoice.
Legislation and disputes
This guarantee is subject to French law and all European directives or
international treaties in force at the time of the claim, applicable in
France. In case of disputes concerning its interpretation or execution, the
High Court of Montpellier (France) shall have exclusive jurisdiction.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>