RAB TOMO- 2FT Adjustable Light Installation Guide
- June 16, 2024
- RAB
Table of Contents
RAB TOMO- 2FT Adjustable Light
Product Information
Specifications :
- Product Name : TOMO LED Lighting
- Available Sizes : 2FT, 4FT, 8FT
- Mounting Options : Surface Mounting and Canopy Kit-to-Fixture
- Energy Efficiency : Energy-efficient LED lighting
Product Usage Instructions
Surface Mounting :
- Secure the Surface Mounting Plate to the Junction Box (by others). For longer fixtures, additional attachment to the ceiling may be needed.
- Remove the Silicone Plugs located on each end of the Housing Cover.
- Pull the End Caps out of each end of the fixture to separate the Housing Cover from the Lens and Tray Assembly. Slide the Housing Cover either right or left to unlock it from the Key Slots.
- Pull the supply wires from the Junction Box (by others) through the center of the Surface Mounting Plate. Use appropriate UL rated wire connectors to make electrical splices to fixture leads.
- Align the Surface Mount Adapter Plate to the Housing Cover and secure it using the provided Screws.
- Follow appropriate wiring instructions per code.
- Push the Lens and Tray Assembly into the Housing Cover. Align the Keys into Key Slots and slide to the right or left to lock the Housing Cover into the Lens and Tray Assembly.
- Snap-on the End Caps and insert Silicone Plugs into the Housing Cover.
Canopy Kit-to-Fixture Installation:
- Remove the End Caps and slide the Lens Tray Assembly from the Housing Cover to release the Tray Assembly by sliding the fixture to the right to unlock it from the Key Slots.
- For Canopy Mounting, remove the two Knockouts on the Housing Cover.
- Insert the Cable Couplers from the inside of the Housing Cover through the two respective Cable Coupler Knockouts.
- Secure the Cable Couplers with Cable Coupler Nuts onto the Housing Cover.
Frequently Asked Questions
How can I contact RAB Lighting for comments or inquiries?
You can call the Marketing Department at 888-RAB-1000 or email them at marketing@rablighting.com.
INSTRUCTIONS
FIELD-ADJUSTABLE TOMO™ INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING THE FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety.
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING : Make certain power is OFF before installing or maintaining the fixture. No user-serviceable parts inside. The fixture is suitable for indoor applications. Suitable for damp locations. Ceiling, Canopy, and Pendant mount only.
SURFACE MOUNTING
1. Secure the Surface Mounting Plate to the Junction Box (by others).
(Additional attachment to the ceiling may be needed for longer fixtures). 8ft
TOMO includes a 2nd Surface Mounting Plate and Surface Mount Adapter Plate
(see Fig. 2).
2. Remove Silicone Plugs located on each end of the Housing Cover as shown in
Fig. 2 (do not discard Silicone Plugs).
3. Pull the End Caps out of each end of the fixture as shown in Fig. 1.
Separate the Housing Cover from the Lens and Tray Assembly by sliding the
Housing Cover either right of left to unlock from Key Slots as shown in Fig.
3. Pre-installed Tether Cables (2) will prevent Lens and Tray Assembly from
separating from Housing Cover (Fig. 1).
4. Pull supply wires from the Junction Box (by others) through the center of
the Surface Mounting Plate. Use appropriate UL rated wire connectors as
required by NEC and local code to make electrical splices to fixture leads.
5. Align the Surface Mount Adapter Plate to the Housing Cover. Using (4)
Screws (provided) secure Surface Mount Adaptor Plate and Housing Cover to the
Surface Mounting Plate.
6. Follow appropriate wiring instructions per code (Fig. 12).
7. Push the Lens and Tray Assembly into the Housing Cover. Align Keys into
Key Slots and slide to the right or left to lock the Housing Cover into the
Lens and Tray Assembly. Snap on End Caps and insert Silicone Plugs into
Housing Cover.
WARNING : To prevent wiring damage or abrasion, do not expose wiring to the edges of sharp objects.
CANOPY KIT-TO-FIXTURE INSTALLATION
- Remove End Caps. Slide Lens Tray Assembly from Housing Cover to release Tray Assembly by sliding the fixture to the right to unlock from Key Slots as shown in Fig. 3. Pre-installed Tether Cables (2) will prevent Lens and Tray Assembly from separating from Housing Cover as shown in Fig. 1.
- For Canopy Mounting, remove (2) Knockouts on the Housing Cover as shown in Fig. 4.
- Insert Cable Couplers from the inside of the Housing Cover through the two respective Cable Coupler Knockouts as shown in Fig. 5.
- Secure the Cable Couplers with Cable Coupler Nuts onto the Housing Cover as shown in Fig. 5.
- Insert the Cable into the Cable Couplers. Adjust the length of the Cable and tighten the Locknuts and trim any excess cable inside the fixture.
- Pull supply wires through Power Cord Knockout and make a connection inside the fixture. Pass the Power Cord and Cable through the Canopy Rings. Adjust the length of the Power Cord and tighten it on the Canopy with Strain Reliefs (Fig. 6).
- Mount all Canopies to the Fixture with appropriate Cable length.
- Follow appropriate wiring instructions per NEC and local code (Fig. 12).
CANOPY-TO-SURFACE MOUNTING
- Slide the Power Cord through the hole on the Canopy and tighten with Strain Relief.
- Connect wires per NEC and local code as shown in the wiring diagram (Fig. 12). Push all wires back into the Junction Box. Be careful not to pinch wires. Mount the Cross Bar on Junction Box.
- Mount the Canopy to the Junction Box. Push the Cable Coupler on the 1/4-20 Stud and tighten the Coupler.
- Canopy and Cable without Power Cord can be mounted with a 1/4 -20 Stud and hardware appropriate to mounting surface.
- Push Lens and Tray Assembly into the Housing Cover. Align Keys into Key Slots and slide to the left to lock the Housing Cover into the Lens and Tray Assembly. Snap on End Caps.
WARNING : To prevent wiring damage or abrasion, do not expose wiring to edges of sharp objects.
CONTINUOUS RUN MOUNTING
-
Multiple fixtures can be mounted together using TOMO CONNECT (sold separately).
Note : Continuous Run Mounting is not available with LIGHTCLOUD® /LC, /LC/E, /LCB suffix. -
For continuous run, remove fixture End Caps (Fig. 6). Pop out Silicone Plugs, push Fixtures together using TOMO CONNECT (ordered separately) between fixtures for quick connect installation (Fig. 7). TOMO CONNECT is provided with (2) Fixing Screws. Install Fixing Screws in Silicone Plug points. Only (1) one Fixture needs to be electrically hard wired from above (Fig. 8).
-
CAUTION: The maximum number of fixtures allowed to be linked together is indicated in table below (120V through 277V only).
WARNING : To prevent wiring damage or abrasion, do not expose wiring to sharp objects.
Catalog # | Maximum Number of Linked Fixtures |
---|---|
TOMO-2 | Up to 28 fixtures |
TOMO-4 | Up to 14 fixtures |
TOMO-8 | Up to 7 fixtures |
FIELD ADJUSTMENT
Follow the instructions below to change the fixture Color Temperature (CCT)
and Power (W) from the factory settings.
Factory Settings : TOMO-2 18W / 4000K
- TOMO-4 36W / 4000K
- TOMO-8 72W / 4000K
- Remove End Caps. Slide Lens Tray Assembly from Housing Cover to release Tray Assembly from Housing Cover bysliding the fixture to the right to unlock from Key Slots as shown in Fig. 3. Pre-installed Tether Cables (2) will prevent Lens and Tray Assembly from separating from Housing Cover as shown in Fig. 1.
- Locate the selector switches inside the Lens & Tray Assembly as shown below for TOMO-2, TOMO-4 TOMO-8 (Fig. 9, 10, 11).
- Note: TOMO-8 is equipped with two (2) Color Temperature (CCT) switches and (2) two Power (W) switches.
- Select a Color Temperature (CCT) and Power (W) by sliding the respective switch to the desired value.
- After the switch is positioned to the desired setting, push Lens and Tray Assembly into the Housing Cover. Align Keys into Key Slots and slide to the left to lock the Housing Cover into the Lens and Tray Assembly. Snap on End Caps.
WARNING : To prevent wiring damage or abrasion, do not expose wiring to edges of sharp objects.
PIR MODELS (INTERNAL)
See factory settings below (optional remote sold separately for custom settings, CAT# TOMO-REMOTE). Factory Settings:
- Hold Time : 1 Minute
- Stand-by period : 1 Minute
- Stand-by dimming level : 10%
- Constant Lux : 50Lux
- Detection range : Disabled
DETECTION PATTERN
DIMMABLE WIRING
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz. For 0-10V dimming, follow the wiring directions as shown in Fig. 12.
- Connect the black fixture lead to the LINE supply lead.
- Connect the white fixture lead to the COMMON supply lead.
- Connect the GROUND wire from fixture to supply ground.
- Connect the purple fixture lead to the (V+) DIM lead.
- Connect the pink fixture lead to the (V-) DIM lead.
- Cap the yellow fixture lead, if present. Do NOT connect.
MAINTENANCE AND TROUBLESHOOTING
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch.
Do not clean or maintain while fixture is energized.
- Clean acrylic lens with non-abrasive cleaning solution.
- Do not open the fixture to clean the LEDs. Do not touch the LEDs.
TROUBLESHOOTING
- Check that the line voltage at the fixture is correct. Refer to wiring directions.
- Is the fixture grounded properly?
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation vor maintenance.
BATTERY BACKUP MODELS
WIRING
CAUTION: FOR BATTERY BACKUP FIXTURE (TOMO-4/TOMO-8) Voltage could be present in BATTERY. To prevent high voltage from being present on output leads, Inverter Connector must be open. Do not join BATTERY connector until installation is complete and AC power is supplied to the emergency driver (Fig. 13).
NOTE: Make sure that the necessary branch circuit wiring is available. An UNSWITCHED AC source of power is required. The emergency driver must be fed from the same branch circuit as the LED driver.
CAUTION: Do not use any supply voltage other than 120-277V 50/60 HZ.
- Connect UNSWITCHED HOT fixture lead to HOT AC supply line.
- If using an UNSWITCHED circuit, connect UNSWITCHED and SWITCHED lines together.
- If using a SWITCHED circuit, connect SWITCHED HOT AC fixture lead to the external control.
- For 0-10V dimming, connect DIM (+) purple lead and DIM (-) pink lead to 0-10V dimmer connections.
- Connect GROUND lead from the fixture to the supply ground. Do not connect GROUND to the output leads.
- All unused leads must be capped and insulated.
- After installation is complete, supply AC power to the fixture and connect the BATTERY (Fig. 13).
- When power is on, the fixture should be on and the Charging Indicator Light should illuminate to indicate the battery is charging.
- Once the BATTERY has charged for at least one hour, a short duration test may be performed by pressing the test button.
- After the battery has charged for 24 hours, a long duration test can be performed by shutting power to the fixture.
OPERATION
- When AC power is applied, the charging indicator light is illuminated indicating that the BATTERY is being charged.
- When power fails, the standby power automatically switches to backup mode at reduced power resulting in lower illumination. The emergency driver supplies power in standby mode for a minimum of 90 minutes.
- When AC power is restored, the emergency driver automatically returns to charging mode.
MAINTENANCE
Although no routine maintenance is required to keep the emergency driver functional, it should be checked periodically to ensure that it is working. The following schedule is recommended:
- Visually inspect the charging indicator light monthly. It should be illuminated.
- Test the emergency operation of the fixture at 30-day intervals for a minimum of 30 seconds.
- Conduct a 90-minute discharge test once a year. Fixture would operate at reduced illumination for a minimum of 90 minutes.
TROUBLESHOOTING
- Is the fixture grounded properly?
- If the charging indicator light does not illuminate after pressing the Test Button (Fig. 14), check if battery is connected properly.
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
Contacts
Easy Answers
- Visit our website for product info rablighting.com
Tech Help Line
- Call our experts: 888 722-1000
- e-mail: Answered promptly – sales@rablighting.com
Free Lighting Layouts
Answered online or by request
© 2022 RAB LIGHTING Inc.
WARRANTY
RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.
© 2022 RAB LIGHTING Inc.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>