- Package Contents
- Features
- Front Panel Components
- Port Functions
- Rear Panel Components
- Side Panel Components
- Installation Guidelines
- Installing the Switch without a Rack
- Installing the Switch in a Standard 19″ Rack
- Installing Transceivers into the Transceiver Ports
- Power On (AC Power)
- Switch to an End Node
- Switch to Another Switch
- Switch to a Server
- Management Options
- Connecting to the Console Port
- Connecting using SNMP
- Introduction
- Logging into the Web UI
- Web User Interface (Web UI)
- Appendix A – Technical Specifications
- Safety Instructions
- General Precautions for Rack-Mountable Products
- Protecting Against Electrostatic Discharge
- Additional Info
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Multi-G Ethernet Smart Managed Switch
DMS-1250 Series
Hardware Installation Guide
DMS-1250 Series Multi G Ethernet Smart Managed Switch
DMS-1250 Series Multi-G Ethernet Smart Managed Switch Hardware Installation
Guide
Information in this document is subject to change without notice. Reproduction
in any manner whatsoever, without the written permission of D-Link
Corporation, is strictly forbidden.
Trademarks used in this text: D-Link and the D-LINK logo are trademarks of
D-Link Corporation; Microsoft and Windows are registered trademarks of
Microsoft Corporation.
Other trademarks and trade names may be used in this document to refer to
either the entities claiming the marks and names or their products. D-Link
Corporation disclaims any proprietary interest in trademarks and trade names
other than its own.
© 2023 D-Link Corporation. All rights reserved.
April 2023
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
CE Mark Warning
This equipment is compliant with Class A of CISPR 32. In a residential
environment, this equipment may cause radio interference.
Safety Compliance
Warning: Class 1 Laser Product: When using a fiber optic media expansion
module, never look at the transmit laser while it is powered on. In addition,
never look directly at the fiber TX port and fiber cable ends when they are
powered on.
Ensure to connect the power cord to a socket-outlet with earthing connection.
Intended Readers
The DMS-1250 Series Multi-G Ethernet Smart Managed Switch Hardware
Installation Guide contains detailed information about the hardware
specifications of the switches in this series. It also contains brief
information on how to configure and manage a switch in this series. This
manual is intended for advanced level users that are familiar with network
management concepts and terminology. For all practical reasons, all the
switches in this series will simply be referred to as the Switch throughout
this manual.
Typographical Conventions
Convention | Description |
---|---|
Boldface Font | This convention is used to place emphasis on keywords. It also |
indicates a button, toolbar icon, menu, menu item, system message, or a prompt
appearing on the screen. For example, click the Apply button.
Initial capital letter| This convention is used to indicate a window name or
keyboard key. For example, press the Enter key.
Blue Courier Font| This convention is used to represent a Command Line
Interface (CLI) example.
Notes and Cautions
NOTE: A note indicates important information that helps you make better
use of your device.
CAUTION: A caution indicates a potential for property damage, personal
injury, or death.
Switch Description
The DMS-1250 Series is D-Link’s next generation Smart Managed Switch. The
Switch has a combination of 2.5GBASE-T and SFP+ ports that may be used to
connect various networking devices to the Switch. The SFP+ ports are used with
fiber-optical transceiver cabling in order to uplink various other networking
devices for a 1Gbps or 10 Gbps link that may span great distances.
The D-Link DMS-1250 Series includes the following switches:
- DMS-1250-10S: Eight 2.5GE Smart Managed switch with 2 SFP+ ports.
- DMS-1250-10SP: Eight 2.5GE POE Smart Managed switch with 2 SFP+ ports.
- DMS-1250-10SPL: Eight 2.5GE POE Smart Managed switch with 2 SFP+ ports.
- DMS-1250-12TP: Eight 2.5GE POE Smart Managed switch with 2 SFP+ ports and 2 10GE ports.
Package Contents
Open the shipping carton of the Switch and carefully unpack its contents. The box should contain the following items:
- One DMS-1250 Series switch.
- One Safety Notice.
- One AC power cord or power adaptor.
- One rack mounting kit (two brackets and screws).
- Four rubber feet with adhesive backing.
- One power cord retainer set (if with AC inlet power port).
- One RJ45 console cable
- Additional documents based on local regulation requirement (optional).
If any item is missing or damaged, please contact your local D-Link reseller for replacement.
Features
The list of features below highlights the significant features of the Switch.
- Supports a 16K MAC address table.
- Supports Flow Control (802.3x) in full-duplex compliant.
- Supports Jumbo Frames of up to 12KB.
- Supports Spanning Tree with 802.1D 2004 STP/RSTP and 802.1Q 2005 MSTP.
- Supports Loopback Detection (LBD).
- Supports Link Aggregation (802.3ad and 802.3AX) with a maximum of 8 groups per Switch.
- Supports Port Mirroring.
- Supports Layer 2 Multicast Filtering.
- Supports IGMP Snooping (v1, v2, v3 awareness) with up to 256 snooping groups and 128 static multicast addresses. MLD Snooping (v1, v2 awareness) with up to 256 snooping groups and 64 static multicast addresses. IGMP Snooping and MLD Snooping share 128 static groups and 256 snooping groups.
- Supports Virtual LAN (802.1Q) with up to 4K VLAN groups.
- Supports Port-based VLAN.
- Supports Asymmetric VLAN.
- Supports Auto Voice and Surveillance VLAN.
- Supports IPv4/IPv6 interfaces.
- Supports Static Routing.
- Supports Quality of Service (QoS) with Queue Handling and Class of Service (CoS).
- Supports Access Control List (ACL).
- Supports Secure Shell (SSHv2) with IPv4/IPv6 access.
- Support Transport Layer Security (TLS) versions 1.3.
- Supports Port Security of up to 64 MAC addresses per port.
- Supports Broadcast and Multicast Storm Control.
- Supports Traffic Segmentation.
- Supports D-Link SafeGuard Engine.
- Supports ARP Spoofing Prevention.
- Supports IP-MAC-Port Binding (IMPB).
- Supports DoS Attack Prevention.
- Supports Guest VLAN.
- Supports Link Layer Discovery Protocol (LLDP) with LLDP-MED.
- Supports Accessibility using multiple interfaces like the Command Line Interface (CLI), Web-based Graphical User Interface (Web-based GUI), and more.
- Supports Telnet Server.
- Supports Trivial File Transfer Protocol (TFTP) Client.
- Supports Simple Network Management Protocol (SNMP) version 1, 2c, and 3.
- Supports DHCP Client.
- Support Dual Images and Configurations.
- Supports Simple Network Time Protocol (SNTP).
- Support Power Saving using the Link Status Mode.
- Support Time-based Power-over-Ethernet (PoE).
- Supports IEEE 802.3az compliance.
- Supports D-Link Discovery Protocol (DDP).
- Supports MIBs.
Note: The features are subject to change based on implementation plan without prior notice.
Front Panel Components
The front panel of the Switch features a variety of LED indicators, ports, a Reset button, and a Mode button (only of PoE supported switches).
Ports
Ports that can be found on the front panel of this switch are listed in the
table below.
Port | Description |
---|---|
Console | The RJ45 console port can be used to connect to the command line |
interface (CLI) of the switch for configuration, management and monitoring
(for DMS-125010S/DMS-1250-10SP/DMS-1250-12TP).
100/1000/2.5GBASE-T RJ45 Ports| The DMS-1250 series Switches are equipped with
2.5GE RJ45 Ethernet ports.
These ports can operate at 100Mbps, 1Gbps and 2.5Gbps wire-speeds.
100/1000/2.5GBASE-T RJ45 PoE Ports| DMS-1250-10SP, DMS-1250-12TP and
DMS-1250-10SPL Switches are equipped with 8 RJ45 PoE Ethernet ports. These
ports can operate at 100 Mbps, 1 Gbps and 2.5 Gbps wire-speeds and support PoE
function.
10 Gigabit SFP+ Ports| The Switch is equipped with SFP+ ports. These ports can
operate at 1 Gbps and 10 Gbps wire-speeds and support a wide collection of
SFP/SFP+ transceivers.
100/1000/2.5G/5G/10GBASE- T RJ45 Ports| The DMS-1250-12TP Switch supports 2
RJ45 10 Gbps Ethernet ports. These ports can operate at 100, 1000, 2500, 5000
and 10000 Mbps wire speeds.
CAUTION: This equipment is to be connected only to PoE networks without
routing to the outside plant.
For a complete list of SFP/SFP+ transceivers that are compatible with this
switch, refer to the SFP+ Ports section in Port Functions.
Reset Button
On the front panel of the Switch is a Reset button. The Switch will reboot or
reset to factory default settings depending on how long this button is
pressed.
- Press and hold the Reset button for less than 5 seconds (release before 5 seconds) to reboot the Switch. All unsaved configurations will be lost.
- Press and hold the Reset button for more than 5 seconds (release between 6 and 10 seconds or above) to reset the software configuration of the Switch to the factory default settings. All the port LEDs will light up (solid amber) for 2 seconds to indicate the start of the factory reset procedure.
LED Indicators
Located on the front panel of this switch are LED indicators: Power, Console,
Fan Error, and Link/Act indicators for all the ports.
Location | LED indicator | Color | Status | Description |
---|---|---|---|---|
Per Device | Power | Green | Solid Light | Device Power On |
Light off | Device Power Off |
Console
DMS- 1250- 10S DMS-1250-10SP DMS-1250-12TP| Green| Solid light| RJ-45 Console
on
Light off| Console off
Fan Error
DMS- 1250- 10SP
DMS-1250-12 TP| Red| Solid light| The fan has run time failure and is brought
offline
PoE Max.
DMS- 1250- 10SP DMS-1250-12 TP DMS- 1250- 10SPL| Amber| Solid light| Total
power output exceeds Guard Band threshold. The PD will be denied based on port
priority or other PoE rules.
Blinking| When the total power output becomes sufficient and allows to connect
more PDs (more than 7 Watts), PoE MAX LED will blink 5 seconds.
Light off| The PoE power is sufficient and below the guard band threshold.
LED Mode DMS-1250-10SP DMS-1250-12TP DMS- 1250- 10SPL| Green| Solid light| A
LED Mode push button is allowed to select the port Link/ACT status or PoE
status.
•Link/Act/Speed Mode
•PoE Mode
LED Per 2.5GBASE-T Multi-gig Port| LinIdAct/Speed| Blue| Solid light| When
there is a secure 2.5Gbps connection at the port.
Blinking| When there is reception or transmission occurring at the port
Green| Solid light| When there is a secure 1000Mbps connection at the port.
Blinking| When there is reception or transmission occurring at the pot
Amber| Solid light| When there is a secure 10/100Mbps connection at the port.
Blinking| When there is reception or transmission occurring at the port
Off| Light off| No link
LED Per 10GBASE-T Multi-gig Port| Link/Act/Speed DMS-1250-12TP| Blue
and Green| Solid light| When there is a secure 10Gbps connection at the port.
Blinking| When there is reception or transmission occurring at the port
Blue
and Amber| Solid light| When there is a secure 5Gbps connection at the port.
Blinking| When there is reception or transmission occurring at the port
Blue| Solid Light| When there is a secure 2.5Gbps connection at the port.
Blinking| When there is reception or transmission occurring at the port.
Green| Solid light| When there is a secure 1000Mbps connection at the port.
Blinking| When there is reception or transmission occurring at the port.
Amber| Solid light| When there is a secure 10/100Mbps connection at the port.
Blinking| When there is reception or transmission occurring at the port.
Off| Light off| No link
LED Per SFP+ Port| Link/Act/Speed| Green| Solid light| When there
is a secure 10Gbps connection at the port.
Blinking| When there is reception or transmission occurring at the port.
Amber
| Solid light| When there is a secure 1000Mbps connection at the port.
Blinking| When there is reception or transmission occurring at the port.
Off| Light off| No link
LED Per PoE Port| PoE Status| Green| Solid light| Power devices
insert and the PSE supplies the port power successfully.
Amber| Solid light| Power devices insert but failure occurs.
(PSE can’t provide power to PD due to PD error, over current or power budget
shortage.)
Off| Light off| PoE Port is not activated, or no PD connected.
Port Functions
Feature | Description |
---|---|
Console Port | RJ45 interface for Out-Of-Band (OOB) CLI configuration |
RJ45 Ports | Compliant with the following standards: |
• IEEE 802.3 compliance
• IEEE 802.3u compliance
• IEEE 802.3ab compliance
• IEEE 802.3az compliance
• IEEE 802.3bz compliance
• IEEE 802.3an compliance
Support Half-Duplex and Full-Duplex
• IEEE 802.3x Flow Control support for Full-Duplex mode
• Back Pressure for Half-Duplex mode
• Head-of-line blocking prevention
• Manual/auto MDI/MDIX configuration
• Auto-Negotiation for each port
SFP/SFP+ Ports| Compliant with the following standards:
• IEEE 802.3ae compliance
• IEEE 802.3z compliance
SFP Transceivers Supported:
• DEM-310GT (1000BASE-LX, single-mode, 10 km, with DDM)
• DEM-311GT (1000BASE-SX, multi-mode, 550 m)
• DEM-312GT2 (1000BASE-SX, multi-mode, 2 km)
• DEM-314GT (1000BASE-LHX, single-mode, 50 km)
• DEM-315GT (1000BASE-ZX, single-mode, 80 km)
• DGS-712 (1000BASE-T)
WDM (BiDi) SFP Transceivers Supported:
• DEM-330T (1000BASE-BX-D, single-mode, 10 km, TX: 1550 nm / RX: 1310 nm)
• DEM-330R (1000BASE-BX-U, single-mode, 10 km, TX: 1310 nm / RX: 1550 nm)
• DEM-331T (1000BASE-BX-D, single-mode, 40 km, TX: 1550 nm / RX: 1310 nm)
• DEM-331R (1000BASE-BX-U, single-mode, 40 km, TX: 1310 nm / RX: 1550 nm)
SFP+ Transceivers Supported:
• DEM-431XT (10GBASE-SR,multi-mode, 80 km, without DDM)
• DEM-432XT (10GBASE-LR, single-mode, 10 km, without DDM)
• DEM-433XT (10GBASE-ER, single-mode, 40 km, without DDM)
• DEM-434XT (10GBASE-ZR, single-mode, 80 km, without DDM)
• DEM-435XT (10GBASE-LRM Multi-Mode, 200M SFP+ Transceiver)
• DEM-410T (10GBASE-T Copper SFP+ transceiver, 30M)
WDM (BiDi) SFP+ Transceivers Supported:
• DEM-436XT-BXD (10GBASE-LR, single-mode, 20 km, TX: 1330 nm / RX: 1270 nm,
without DDM)
• DEM-436XT-BXU (10GBASE-LR, single-mode, 20 km, TX: 1270 nm / RX: 1310 nm,
without DDM)
FP+ Direct Attached Cables (DAC) Supported:
• DEM-CB100S (10G SFP+, 1 m)
• DEM-CB300S (10G SFP+, 3m)
PoE Ports
DMS-1250-10SP
DMS-1250-12TP
DMS-1250-10SPL| Supports the following:
• IEEE802.3af/at PoE+ compliance (for DMS-1250-10SP/DMS-1250- 12TP)
• IEEE802.3af/at/bt PoE++ compliance (for DMS-1250-10SPL)
• The auto-discovery feature automatically recognizes the connection of the PD
device and provides power
• Automatically disable ports if the port current is over 400~450mA while
other ports will remain active
• Active circuit protection automatically disables the port if there is a
short while other ports remain active
• For 802.3af/at/bt capable devices will provide the power for the following
classifications below:
Class| Usage| Max Power used by PD
---|---|---
0| Default| 0.44 Watt to 12.95 Watt
1| Optional| 0.44 Watt to 3.84 Watt
2| Optional| 3.84 Watt to 6.49 Watt
3| Optional| 6.49 Watt to 12.95 Watt
4| Optional (802.3at Only)| 12.95 Watt to 25.5 Watt
Feature| Description
---|---
| 5| Type 3 (802.3bt)| Max Power used by PD: 51 Watt
• The total PoE power budget of DMS-1250-10SP/12TP : 240 W.
Rear Panel Components
The rear panel of this switch features a security lock, a GND, an AC power connector, and a power cord retainer hole. Components that can be found on the rear panel of this switch are listed in the table below.
Component | Description |
---|---|
Security Lock | Provide a Kensington-compatible security lock to be able to |
connect to a secure immovable device. Insert the lock into the notch and turn
the key to secure the lock. The lock-and-cable apparatus should be purchased
separately.
Switch GND| Use an electrical grounding wire and connect one end of the wire
to the Switch GND and the other end of the wire to an electrical grounding
point most commonly found on the Switch mounting rack itself.
AC or DC power connector| Use with AC power cord or external power adapter to
supply power to the switch.
Power Cord Retainer| The power cord retainer is used to fix the AC power cord
in place and not easily loose. For DMS-1250-10S/DMS-1250-10SP/DMS-1250-12TP)
Note: DMS-1250-10SPL DC power connector is in front panel.
Side Panel Components
The side panels of this switch contain heat vents, fans, and rack-mounting
screw holes. The heat vents are used to dissipate internal heat and facilitate
internal air circulation. Do not block these openings. Leave at least 4 inches
of space at the sides of the Switch for proper ventilation. Without proper
heat dissipation and air circulation, system components might overheat which
could lead to system failure or even severely damaged components. Smart
Fans
The DMS-1250 Series Switches includes smart fans that will automatically
change their speed depending on the internal temperature detected by the
sensors built-in the Switch’s hardware.
The following will explain at what temperature the speed of the fan(s) will
change:
- DMS-1250-10S: Fanless
- DMS-1250-10SP/DMS-1250-12TP: 5-speed Smart FAN setting as below:
- T1 — 10°C, FAN Duty 30%
- T2 — 25°C, FAN Duty 40%
- T3 — 40°C, FAN Duty 60%
- T4 — 50°C, FAN Duty 70%
- T5 — 55°C, FAN Duty 100%
- DMS-1250-10SPL: Fanless
DMS-1250 also can configure the operation state of internal fans through Web
UI or command line interface (CLI).
The switch fans can be manually set to Fan Off mode or Quiet mode if the
ambient temperature or PoE load do not exceed the critical level. Please refer
to User/CLI manual for more details.
Installation Guidelines
This section will discuss the hardware installation guidelines that the user must follow in order to properly and safely install this switch into the appropriate environment.
- Visually inspect the power cord or power adapter is securely attached to the power connector on the Switch, and the electrical outlet that supplies power.
- Install the Switch in a fairly cool and dry place within the acceptable operating temperature and humidity ranges. For more information about the acceptable operating temperature and humidity ranges, refer to the Physical and Environmental section.
- Install the Switch in a site free from strong electromagnetic field generators such as motors, vibration, dust, and direct exposure to sunlight.
Installing the Switch without a Rack
This section is used to guide the user through installing the Switch in an area other than a switch rack. Attach the included rubber feet to the bottom of the Switch. Take note that there should be marked blocks on the bottom of the Switch to indicate where to attach the rubber feet. These markings are usually found in each corner on the bottom of the device. The rubber feet cushion the Switch, protecting the casing from scratches and preventing it from scratching other surfaces. Install the Switch on a sturdy, level surface that can support the weight of the Switch (see the Weight section in Appendix A – Technical Specifications.). Do not place any heavy objects on the Switch. The power outlet should be within 1.82 meters (6 feet) of the Switch. Make sure that there is proper heat dissipation from and adequate ventilation around the Switch. Leave at least 10 cm (4 inches) of space at the front, sides, and rear of the Switch for ventilation.
Installing the Switch in a Standard 19″ Rack
This section is used to guide the user through installing the Switch into a
switch rack. The Switch can be mounted in a standard 19″(1U) rack using the
provided mounting brackets.
Fasten the mounting brackets to the sides of the Switch using the screws
provided. Fasten the mounting brackets in any available open space in the rack
using the screws provided. Make sure that there is adequate space around the
Switch to allow for proper airflow, ventilation, and cooling.
Installing Transceivers into the Transceiver Ports
The Switch is equipped with Small Form-factor Pluggable (SFP) and Enhanced
Small Form-factor Pluggable (SFP+) ports that can be used to connect various
other networking devices to this switch that do not support the standard RJ45
wiring connection. These ports are generally used to connect this switch to
optical fiber connections and can be used to connect devices to the Switch
over great distances. The maximum distance that the RJ45 wiring connection can
reach is 100 meters. Fiber optic connections can span several kilometers.
The figure below illustrates how to properly insert SFP/SFP+ transceivers into
the Switch’s SFP/SFP+ ports. The SFP/SFP+ ports also support other transceiver
form factors like SFP and SFP+ transceivers. A complete list of SFP/SFP+
transceivers, compatible with this switch, can be found in the SFP+/SFP Ports
section in Appendix A – Technical Specifications at the end of this document.
NOTE: Only use pluggable optical modules and Direct-Attach Cables (DAC) that meet the following regulatory requirements:
- Class 1 Laser Product
- UL and/or CSA registered component for North America
- FCC 21 CFR Chapter 1, Sub-chapter J in accordance with FDA & CDRH requirements
- IEC/EN 60825-1/-2: 2007 2nd edition or later, European Standard
Power On (AC Power)
Plug one end of the AC power cord into the power socket of the Switch and the other end into the local power source outlet. After the system is powered on, the LED will blink green to indicate that the system is booting up.
Power Failure (AC Power)
In the event of a power failure, just as a precaution, unplug the power cord
from the Switch. After the power returns, plug the power cord back into the
power socket of the Switch.
Installing Power Cord Retainer
To prevent accidental removal of the AC power cord, it is recommended to
install the power cord retainer together with the power cord.
With the rough side facing down, insert the tie wrap into the hole below the
power socket. Plug the AC power cord into the power socket of the Switch.
Slide the retainer through the tie wrap until the end of the cord. Circle the
tie of the retainer around the power cord and into the locker of the retainer.
Fasten the tie of the retainer until the power cord is secured.
*All the product pictures shown are for illustration purposes only. Actual product appearance may differ from that depicted on the packaging/documentation
Switch to an End Node
An end node is a generic name for edge networking devices that will be
connected to this switch. Typical examples of end nodes are Personal Computers
(PCs), Notebooks, Access Points, Print Servers, VoIP Phones and more. Each end
node should be fitted with a RJ45 networking port. Normally, end nodes will
connect to this switch by using a standard twisted-pair UTP/STP network cable.
When a successful connection is established, the corresponding port light will
illuminate and blink to indicate that network activity is taking place on that
port.
The diagram below displays a typical end node connected to the Switch.
Switch to Another Switch
The Switch can be used to connect to any other switch or hub in the network.
This network topology is used when the Switch does not have enough ports to
cater for all the end nodes in the network.
There is a great deal of flexibility on how connections are made using the
appropriate cabling.
- Connect a 10BASE-T switch port to the Switch using a twisted-pair Category 3, 4, or 5 UTP/STP cable.
- Connect a 100BASE-TX switch port to the Switch via a twisted-pair Category 5 UTP/STP cable.
- Connect a 1000BASE-T switch port to the Switch via a twisted pair Category 5e UTP/STP cable.
- Connect a switch supporting an optical fiber uplink to the Switch’s SFP/SFP+ ports via fiber optical cabling.
- Connect a 10GBASE-T switch port to the Switch via twisted pair Category 6a UTP/STP cable¹ .
1 10GBASE-T ports may be limited to support 10/100Mbps half mode connection.
Switch to a Server
The Switch is ideal for connecting to a network backbone, server, or server farm. The RJ45 ports (Port 11-12) operate at a speed of 100Mbps/1G/2.5G/5G/10G. The SFP+ ports operate at a speed of 1/10 Gbps.
Management Options
This switch provides multiple access platforms that can be used to configure, manage, and monitor networking features available on this switch. Currently there are three management platforms available, which are described below.
Command Line Interface (CLI)
This switch can be managed, out-of-band, by using the console port on the
front panel of the Switch. Alternatively, the Switch can also be managed, in-
band, by using a Telnet connection to any of the LAN ports on the Switch. The
command line interface provides the access to some of switch management
features.
For more information about the CLI, refer to the DMS-1250 Series CLI Reference
Guide.
SNMP-based Management
The Switch can be managed with an SNMP-compatible console program. The Switch
supports SNMP v1, SNMPv2c and SNMPv3. The SNMP agent decodes the incoming SNMP
messages and responds to requests with MIB objects stored in the database. The
SNMP agent updates the MIB objects to generate statistics and counters.
Web User Interface (Web UI)
The Web UI can be accessed from any computer running web browsing software
from its LAN port when it is connected to any of the RJ45 or SFP/SFP+ ports.
The Web UI on the Switch can also be accessed using an HTTPS (SSL) connection.
This management interface is a more graphical representation of the features
that can be viewed and configured on this Switch. Most of the features
available through the CLI can be accessed through the Web UI. Web browsers
like Microsoft’s Internet Explorer, Mozilla Firefox, Google Chrome, or Safari
can be used.
For more information about the Web UI, refer to the DMS-1250 Series Web UI
Reference Gui
Connecting to the Console Port
The front panel of the Switch provides an RJ45 console port to connect a
remote system for monitoring and configuring the Switch.
To use the console port, the following equipment is needed:
- A terminal or a computer with both RJ45 ethernet port and terminal emulation software.
- A RJ45 Ethernet cable.
To connect the RJ45 console port on the Switch to the computer:
- Connect the Ethernet cable to the RJ45 port on the computer running terminal emulation software then insert the RJ45 connector into the RJ45 console port on the front of the Switch.
To configure the terminal emulation software as follows:
- Select the appropriate serial port (COM1 or COM2).
- Set the data rate to 115200 baud.
- Set the data format to 8 data bits, 1 stop bit, and no parity.
- Set flow control to none.
To be able to view the boot procedure, the Switch needs to be rebooted. The
simplest way, at this stage, to reboot the Switch is to unplug and re-insert
the power cable from and into the power receptacle on the back of the Switch.
After correctly configuring the terminal settings and re-inserting the power
cable, the boot procedure will appear in the terminal. After the boot sequence
has been completed, the console login screen will be displayed.
Connecting to the Switch for the First Time
The Switch supports user-based security that can prevent unauthorized users
from accessing the Switch or changing its configuration. This section will
explain how to log into the Switch’s Command Line Interface via the out-of-
band console connection.
Both the default Username and Password is admin. Enter the username and
password when prompt to do so and press enter after each entry. The CLI prompt
will immediately be available, as shown below. NOTE: For security reasons,
it is highly recommended to configure a personal username and password for
this Switch.
Creating a User Account
One of the first and most important tasks will be to create user accounts.
Logging in using a predefined administratorlevel username will give the user
privileged access to the Switch’s management software. Also this will prevent
unauthorized access to the Switch and record the passwords for future
reference.
An example to create an administrator-level account for the Switch call
‘NewUser’:
In the example above:
- Enter the configure terminal command to enter the Global Configuration Mode. Press ENTER.
- Enter the username NewUser password 12345 command to create a user account with the username of NewUser and a password of 12345. Press ENTER.
NOTE: Passwords are case sensitive. Usernames can be up to 32 characters in length. Passwords can be up to 32 plain-text characters in length.
Configuring the IP Address
Each switch must be assigned its own in-band IP Address, which is used for
communication with an SNMP network manager or other TCP/IP applications. The
Switch’s default IP address is 10.90.90.90 with a subnet mask of 255.0.0.0.You
can change the IP address of the Switch to meet the specification of your
networking address scheme.
The IP address of the Switch must be configured before it can be managed, by
the user, via the Web UI.
An example to change the IP address of the Switch to ‘10.50.50.50’, using a
subnet mask of ‘255.0.0.0’:
In the above example,
- Enter the configure terminal command to enter the Global Configuration Mode. Press ENTER.
- Enter the interface vlan 1 command to enter the VLAN Configuration Mode of the default VLAN 1.
- Enter the ip address 10.50.50.50 255.0.0.0 command to change the IP address of the Switch to 10.50.50.50 and the subnet mask to 255.0.0.0.
The Switch can now be accessed and configured through Telnet or the Web UI. The Switch’s IP address can also automatically be obtained by using the DHCP protocol.
Connecting using SNMP
The Simple Network Management Protocol (SNMP) is an OSI Layer 7 (Application
Layer) protocol designed specifically for managing and monitoring network
devices. SNMP enables network management stations to read and modify the
settings of gateways, routers, switches, and other network devices. Use SNMP
to configure system features for proper operation, monitor performance, and
detect potential problems in the Switch, switch group, or network.
Managed devices that support SNMP include software (referred to as an agent),
which runs locally on the device. A defined set of variables (managed objects)
is maintained by the SNMP agent and used to manage the device. These objects
are defined in a Management Information Base (MIB), which provides a standard
presentation of the information controlled by the on-board SNMP agent. SNMP
defines both the format of the MIB specifications and the protocol used to
access this information over the network.
The Switch supports SNMPv1, SMNPv2c, and SNMPv3. The administrator may specify
which SNMP version to use to monitor and control the Switch. The three SNMP
versions vary in the level of security provided between the management station
and the network device.
In SNMPv1 and SNMPv2c, user authentication is accomplished using ‘community
strings’, which function like passwords. The remote user SNMP application and
the Switch SNMP must use the same community string. SNMP packets from any
station that has not been authenticated are ignored (dropped).
The default community strings for the Switch used for SNMPv1 and SNMPv2c
management access are:
- public – Allows authorized management stations to retrieve MIB objects.
- private – Allows authorized management stations to retrieve and modify MIB objects.
SNMPv3 uses a more sophisticated authentication process that is separated into
two parts. The first part is to maintain a list of users and their attributes
that are allowed to act as SNMP managers. The second part describes what each
user on that list can do as an SNMP manager.
The Switch allows groups of users to be listed and configured with a shared
set of privileges. The SNMP version may also be set for a listed group of SNMP
managers. Thus, a group of SNMP managers can be created to view read-only
information or receive traps using SNMPv1 while assigning a higher level of
security to another group, granting read/write privileges using SNMPv3.
Using SNMPv3 individual users or groups of SNMP managers can be allowed to
perform or be restricted from performing specific SNMP management functions.
The functions that have been allowed or restricted are defined using the
Object Identifier (OID) associated with a specific MIB. An additional layer of
security is available for SNMPv3 in that SNMP messages may be encrypted.
Traps
Traps are messages that are sent by an SNMP-enabled device to the NMS, and can
be used to alert network personnel of events that occur on the Switch. The
events can be as serious as a reboot (someone accidentally turned off the
Switch), or less serious like a port status change. The Switch generates traps
and sends them to a preconfigured IP address, usually an NMS. Typical traps
include trap messages for Authentication Failure and Topology Change.
Management Information Base (MIB)
A Management Information Base (MIB) stores management and counter information.
The Switch uses the standard MIB-II Management Information Base module.
Consequently, values for MIB objects can be retrieved from any SNMP-based
network management software. In addition to the standard MIB-II, the Switch
also supports its own proprietary enterprise MIB as an extended Management
Information Base. The proprietary MIB may also be retrieved by specifying the
MIB Object Identifier. MIB values can be either read-only or read-write.
Introduction
Most software functions of the Switch can be managed, configured, and
monitored via the embedded HTML Web UI.
Management can be done on the Switch from remote stations anywhere on the
network through a standard web browser. The web browser acts as a universal
access tool and can communicate directly with the Switch using the HTTP or
HTTPS (SSL) protocol.
The following web browsers are supported:
- Internet Explorer (version 8,9,10,11)
- Firefox
- Google Chrome
- Safari
- Microsoft Edge
NOTE: The default IP address of this switch is 10.90.90.90, with a subnet
mask of 255.0.0.0.
NOTE: The default username is admin and the default password is admin.
Logging into the Web UI
To access the Web UI, open a standard web browser, enter the Switch’s IP
address into the address bar of the browser, and press the ENTER key. After
pressing the ENTER key, the following authentication window should appear, as
shown below. Enter the User Name and Password in the corresponding fields and
click Login. This will open the Web UI.
Management features available in the Web UI of the Switch are explained below.
Web User Interface (Web UI)
The Web UI provides access to various Switch configuration and management windows. It allows the user to view performance statistics, and permits graphical monitoring of the system’s status.
Areas of the Web UI
After logging into the Switch’s Web UI, the following page will be displayed.
The Web UI can be divided into four distinct areas that are described in more
detail in the table below.
Four main areas are displayed in the window.
Area Number | Function |
---|---|
AREA 1 | This area displays a graphical, near real-time image of the front |
panel of the Switch. This area displays the Switch’s ports and expansion
modules. It also shows port activity based on a specific mode. Some management
functions, including port monitoring, are accessible from here. Click the
D-Link logo to go to the D-Link website.
AREA 2| This area displays a file explorer-type menu tree with all
configurable options.
Select the folder or window to display. Open folders and click the hyperlinked
window buttons and subfolders contained within them to display information
pertaining to that category.
AREA 3| This area displays a toolbar used to access Save and Tools menus.
AREA 4| This area displays graphical, real-time monitoring gauges of Device
Information, CPU Usage, and Memory Usage.
Web Pages
In Area 2, mentioned above, the following main folders will be available for
selecting.
Folder Name | Description |
---|---|
System | Features regarding the Switch’s configuration can be viewed and |
configured in this folder.
Management| Features regarding the Switch’s management can be viewed and
configured in this folder.
L2 Features| Features regarding the Layer 2 functionality of the Switch can be
viewed and configured in this folder.
L3 Features| Features regarding the Layer 3 functionality of the Switch can be
viewed and configured in this folder.
QoS| Features regarding the Quality of Service functionality of the Switch can
be viewed and configured in this folder.
ACL| Features regarding the Access Control List functionality of the Switch
can be viewed and configured in this folder.
Security| Features regarding the Switch’s security can be viewed and
configured in this folder.
OAM| Features regarding the Switch’s Operations, Administration, and
Maintenance (OAM) can be viewed and configured in this folder.
Monitoring| The Switch’s configuration and statistics can be viewed and
configured in this folder.
Green| Features regarding the D-Link Green Technology can be viewed and
configured in this folder.
Appendix A – Technical Specifications
General
Feature | Description |
---|---|
Data Transfer Rates | |
Ethernet | 10 Mbps |
Fast Ethernet | 100 Mbps |
Multi-G Ethernet | – |
10 Multi-G Ethernet | – |
Network Cables | UTP/STP Category 3, 4, 5 for 10BASE-T UTP/STP |
Category.5, 5e for 100BASE-TX UTP/STP Category 5e for 1000/2.5G/5GBASE-T UTP/STP Category 6a for 10GBASE-T
Physical and Environmental
Feature | Description |
---|---|
Internal AC Power Supply | DMS-1250-10S:100~240VAC, 50~60Hz, 0.35A |
DMS-1250-10SP: 100~240VAC, 50~60Hz, 3.48A
DMS-1250-12TP: 100~240VAC, 50~60Hz, 3.51A
DMS-1250-10SPL: 54V/2.78A external power adapter
Security Lock| Provides a Kensington-compatible security lock, on the rear
panel of the Switch, to be able to connect to a secure immovable device.
Insert the lock into the notch and turn the key to secure the lock. The lock-
andcable apparatus
should be purchased separately
Fans| The IC Sensor detects the temperature on the switch automatically and
adjusts the speed.
DMS-1250-10S: Fanless
DMS-1250-10SP: 2 fans
DMS-1250-12TP: 2 fans
DMS-1250-10SPL: Fanless
Power Consumption| Maximum Power Consumption:
DMS-1250-10S: 13.522 Watts
DMS-1250-10SP: 21.221 Watts (w/o PoE), 287.58 Watts (PoE on)
DMS-1250-12TP: 28.33 Watts (w/o PoE), 289.74 Watts (PoE on)
DMS-1250-10SPL: 10.274 Watts (w/o PoE), 147 W (PoE on)
Standby Power Consumption:
DMS-1250-10S: 5.443 Watts
DMS-1250-10SP: 10.936 Watts
DMS-1250-12TP: 14.020 Watts
DMS-1250-10SPL: 10.274W Watts
Temperature| Operating:
0~50 °C for DMS-1250-10-10S/DMS-1250-10SP/DMS-1250-12TP
0~40 °C for DMS-1250-10SPL
| Storage: -20 °C to 70 °C (-4 °F to 158 °F)
Humidity| Operating: 0 % to 95 % RH (non-condensing)
Storage: 0 % to 95 % RH (non-condensing)
Heat Dissipation| DMS-1250-10S: 46.33 BTU/hr
DMS-1250-10SP: 981.223 BTU/hr
DMS-1250-12TP: 988.63 BTU/hr
Dimensions| DMS-1250-12T: 440x210x44mm
DMS-1250-10S/10SP: 330x200x44mm
Weight| DMS-1250-10S: 1.877 kg (4.14 lbs)
DMS-1250-10SP: 2.377 kg (5.24 lbs)
DMS-1250-12TP: 3.24 kg (7.14 lbs)
DMS-1250-10SPL:1.34 kgs (2.95 lbs)
EMC Certifications| CE Class A, FCC Class A, ISED Class A, VCCI Class A, RCM
Class A, BSMI Class A
Safety Certifications| IEC60950-1, IEC62368-1, UL/CSA62368-1, BSMI Class A
Performance
Feature | Description |
---|---|
Transmission Method | Store-and-forward |
Packet Buffer | 12 Mbits per device |
Jumbo Frame Size | 12KB |
Switching Capacity | DMS-1250-10S: 80Gbps |
DMS-1250-1SP: 80Gbps
DMS-1250-12TP: 120Gbps
DMS-1250-10SPL: 80Gbps
Maximum Packet Forwarding Rate| DMS-1250-10S: 59.53Mpps
DMS-1250-10SP:59.53Mpps
DMS-1250-12TP:89.29Mbps
DMS-1250-10SPL: 59.53Mpps
Priority Queues| 8 Priority Queues per port.
MAC Address Table| DMS-1250-10S: 16K
DMS-1250-10SP: 16K
DMS-1250-12TP: 16K
DMS-1250-10SPL: 16K
Supports 256 Static MAC addresses
Safety Instructions
Please pay careful attention to the following safety guidelines to ensure your own personal safety and to help protect your system from potential damage.
Safety Cautions
To greatly reduce the risk of physical injury, electrical shock, fire, and
damage to equipment, observe the following precautions.
Observe and follow service markings.
- Do not attempt to service any product, except when it is explained in the system’s documentation.
- Opening or removing covers, marked with a high voltage sign, may expose the user to electrical shock.
- Only a trained service technician should service components inside these compartments.
If any of the following conditions occur, unplug the product from the electrical outlet and replace the part or contact your trained service provider:
- Damage to the power cable, extension cable, or plug.
- An object has fallen into the product.
- The product has been exposed to water.
- The product has been dropped or damaged.
- The product does not operate correctly when the operating instructions are correctly followed.
General safety cautions:
- Electrical Hazard: Only qualified personnel should perform installation procedures.
- Before servicing, disconnect all power cords to remove power from the device.
- Keep the system away from radiators and heat sources. Also, do not block cooling vents.
- Do not spill food or liquids on system components, and never operate the product in a wet environment. If the system gets wet, contact your trained service provider.
- Do not push any objects into the openings of the system. Doing so can cause fire or electric shock by shorting out interior components.
- Only use this product with approved equipment.
- Allow the product to cool before removing the cover or touching internal components.
- Operate the product only from the type of external power source indicated on the electrical ratings label. If unsure of the type of power source required, consult your service provider or local power company.
- Be sure that attached devices are electrically rated to operate with the power available in your location.
- Use only approved power cable(s). If you have not been provided with a power cable for your system or for any AC-powered option intended for your system, purchase a power cable that is approved for use in your country. The power cable must be rated for the product and for the voltage and current marked on the product’s electrical ratings label. The voltage and current rating of the cable should be greater than the ratings marked on the product.
- To help prevent electric shock, plug the system and peripheral power cables into properly grounded electrical outlets. These cables are equipped with three-prong plugs to help ensure proper grounding. Do not use adapter plugs or remove the grounding prong from a cable. If using an extension cable is necessary, use a 3-wire cable with properly grounded plugs.
- Observe the extension cable and power strip ratings. Make sure that the total ampere rating of all products plugged into the extension cable or power strip does not exceed 80 percent of the ampere ratings limit for the extension cable or power strip.
- To help protect the system from sudden, transient increases and decreases in electrical power, use a surge suppressor, line conditioner, or uninterruptible power supply (UPS).
- Position system cables and power cables carefully. Route cables so that they cannot be stepped on or tripped over. Be sure that nothing rests on any cables.
- Do not modify power cables or plugs. Consult a licensed electrician or your power company for site modifications. Always follow your local or national wiring rules.
When connecting or disconnecting power to and from hot-pluggable power supplies, observe the following guidelines:
- Install the power supply before connecting the power cable to the power supply.
- Unplug the power cable before removing the power supply.
- If the system has multiple sources of power, disconnect power from the system by unplugging all power cables from the power supplies.
- Move products with care and ensure that all casters and stabilizers are firmly connected to the system. Avoid sudden stops and uneven surfaces.
To help avoid damage to the system, be sure that the voltage selection switch, on the power supply, is set to match the power available at the Switch’s location:
- 115V/60Hz is used mostly in North and South America as well as Far Eastern countries like as South Korea and Taiwan
- 100V/50Hz is used mostly in Eastern Japan and 100V/60Hz in Western Japan
- 230V/50Hz is used mostly in Europe, the Middle East, Africa and the Far East
General Precautions for Rack-Mountable Products
Please pay careful attention to the following precautions concerning rack
stability and safety. Systems are considered to be components in a rack. Thus,
a component refers to any system, as well as to various peripherals or
supporting hardware:
CAUTION: Installing systems in a rack without the front and side
stabilizers installed could cause the rack to tip over, potentially resulting
in bodily injury under certain circumstances. Therefore, always install the
stabilizers before installing components in the rack. After installing
system/components in a rack, never pull more than one component out of the
rack on its slide assemblies at one time. The weight of more than one extended
component could cause the rack to tip over and may result in serious injury.
- Before working on the rack, make sure that the stabilizers are secured to the rack, extended to the floor, and that the full weight of the rack rests on the floor. Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks efore working on the rack.
- Always load the rack from the bottom up, and load the heaviest item in the rack first.
- Make sure that the rack is level and stable before extending a component from the rack.
- Use caution when pressing the component rail release latches and sliding a component into or out of a rack; the slide rails can pinch your fingers.
- After a component is inserted into the rack, carefully extend the rail into a locking position, and then slide the component into the rack.
- Do not overload the AC supply branch circuit that provides power to the rack. The total rack load should not exceed 80 percent of the branch circuit rating.
- Ensure that proper airflow is provided to components in the rack.
- Do not step on or stand on any component when servicing other components in a rack.
CAUTION: Never defeat the ground conductor or operate the equipment in
the absence of a suitably installed ground conductor. Contact the appropriate
electrical inspection authority or an electrician if uncertain that suitable
grounding is available.
CAUTION: The system chassis must be positively grounded to the rack
cabinet frame. Do not attempt to connect power to the system until grounding
cables are connected. Completed power and safety ground wiring must be
inspected by a qualified electrical inspector. An energy hazard will exist if
the safety ground cable is omitted or disconnected.
Protecting Against Electrostatic Discharge
Static electricity can harm delicate components inside the system. To prevent
static damage, discharge static electricity from your body before touching any
of the electronic components, such as the microprocessor. This can be done by
periodically touching an unpainted metal surface on the chassis.
The following steps can also be taken prevent damage from electrostatic
discharge (ESD):
- When unpacking a static-sensitive component from its shipping carton, do not remove the component from the antistatic packing material until ready to install the component in the system. Just before unwrapping the antistatic packaging, be sure to discharge static electricity from your body.
- When transporting a sensitive component, first place it in an antistatic container or packaging.
- Handle all sensitive components in a static-safe area. If possible, use antistatic floor pads, workbench pads and an antistatic grounding strap.
Additional Info
Documentation/Support/Warranty
Online Documentation
www.dlink.com/resources/business
Online Support
https://www.dlink.com/en/support
Warranty Information
References