USE AND CARE GUIDE
MINI PENDANT LIGHT WITH COLOR PREFERENCE® AND NIGHTLIGHT

NOTE: Keep your receipt and these instructions for proof of purchase.
WARNING: Shut off the power at the circuit breaker or fuse panel before removing the old fixture, ballast, or fluorescent tubes.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.

INSTALLATION

  1.  Shut off power at the electrical panel before beginning the installation.

  2. Remove existing fixture and set aside to recycle in accordance with local

  3. Choose your favorite correlated color temperature (CCT) before installing the fixture.
    NOTE : The factory setting for the correlated color temperature (CCT) is 3000K.

  4. Loosen the screw in strain relief (L) until power cord (B) slides easily, being careful not to completely remove screw. Slide canopy (D) down cord until the fixture (A) is the desired distance below the canopy (D).
    Tighten the screw in the strain relief (L) until cord (B) does not slide.Being careful not to over tighten.
    NOTE: These steps should only be performed by someone familiar with working with electrical wiring. Care must be taken when adjusting the length of the cord (B) to ensure insulation on internal wires is not damaged. After adjusting the required length, tie a knot on the end close to canopy (D) to prevent dragging. Leaving at least 1 inch (25.4mm) of outer insulation above the canopy (D).

  5. Pass the hot and neutral (black and white) wires from the electrical outlet box (H) through the middle hole of the mounting bracket (G).
    Align the mounting bracket (G) using the mounting screws (F) and tighten securely to the electrical box (H).

  6. Connect the hot and neutral (black and white) wires from the electrical box to the same color wires from the power cord (B).
    Connect the grounding wire from the electrical box to the green wire from power cord (B).
    Cover the wire connections using the wire connectors (E). Make sure to fasten them well. Cover the wire connectors (E) with electrical tape (not included) for a more secure connection.
    Wrap the bare grounding wire (K) from the fixture canopy (D) around the green grounding screw (I) on the mounting bracket (G) and tighten the grounding screw (I).

  7. After wires are connected, position the wires back carefully inside the electrical box (H).
    Raise fixture canopy (D) allowing the mounting screw (J) to protrude through the hole in the canopy (D), and secure with cap nuts (E).

PACKAGE CONTENTS

Part Description Quantity
A Fixture body 1
B Power Cord 1
C Cap Nuts 2
D Fixture Canopy 1
E Wire Connector 3
F Mounting Screw for

Electrical Box

| 2
G| Mounting Bracket| 1
H| Electrical Outlet Box (Not included)| 1
I| Grounding Screw| 1
J| Mounting Screw in Bracket| 2
K| Grounding Wire| 1
L| Strain Relief| 1

ETi 547041110 Mini Pendant Light with Color Preference and Nightlight fig
1

SELECTING MAIN LIGHT OR NIGHTLIGHT MODE

The product can be used in one of two modes: Main light mode, which provides full brightness and allows selection from five color temperatures, or nightlight mode.
Nighlight mode provides reduced light output at 2000K color temperature for very soft illumination at night.

TO TURN ON THE MAIN LIGHT

Turn on the light switch to activate the light fixture.

TO CHANGE TO NIGHTLIGHT MODE WITH REDUCED LIGHT OUTPUT:
Switch the main light off and back on again in 3 seconds to active nightlight mode.ETi 547041110 Mini Pendant Light with Color Preference and Nightlight
fig 3

NOTE: The main light will not provide light output when the nightlight trim is illuminated.

TO RETURN TO THE MAIN LIGHT WITH FULL LIGHT OUTPUT WHEN IN NIGHTLIGHT MODE:
Toggle the switch off and back on to active.

WARNING: Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so could lead to electric shock, fire, or other injuries which could be hazardous or even fatal. • Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker. • Under no circumstances should a fixture be hung on house electrical wires, nor should a swag type fixture be installed on a ceiling which contains a radiant type heating system.

NOTICE : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit different from that to which the receiver is connected, and consult the dealer or an experienced radio/TV.

  • Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.

Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. – 5 p.m., CST, Monday – Friday
1-855-ETI-SSLI (1-855-384-7754) www.ETiSSL.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals