TROX IDH Induction Unit Ceiling Installation Guide
- June 16, 2024
- TROX
Table of Contents
TROX IDH Induction Unit Ceiling
Product Information
Specifications
- Type: IDH
- Installation: Ceiling installation
- Air Discharge: One-way or two-way
- Heat Exchanger: Vertical
- Condensate Drip Tray: Yes
Application Range
The IDH Induction unit is designed for heating and cooling in large
internal spaces such as exhibition or production halls. It is suitable for
freely suspended installation.
Optional Equipment and Accessories
- Control System: One-way or two-way air discharge
- Powder Coating: Available in many different colours, e.g. RAL CLASSIC
**Installation
**
To install the IDH Induction unit, follow these steps:
- Select a suitable location on the ceiling for installation.
- Ensure that the ceiling can support the weight of the unit.
- Connect the necessary ductwork to the unit for air supply and discharge.
- If using the condensate drip tray, position it correctly below the unit to collect any condensation.
- Securely mount the unit to the ceiling using appropriate hardware.
INSTALLATION EXAMPLE IDH
Type IDH
Induction unit for ceiling installation, with one-way or two-way air
discharge, vertical heat exchanger and condensate drip tray Induction unit for
heating and cooling, with 2-pipe heat exchanger, for freely suspended
installation in large internal spaces, e.g. exhibition or production halls.
The condensate drip tray is useful if the temperature temporarily falls below
the dew point.
- Very high heating capacity and cooling capacity (up to 27 kW) when installed at a height of 8 to 25 m
- High comfort levels due to low airflow velocity in the occupied zone
- Non-combustible nozzles made of aluminium
- Motorised damper blade allows for precise setting of air discharge direction
- Heat exchanger with plain Cu pipe (Ø22 mm) for the water connection
Optional equipment and accessories
- Control system
- One-way or two-way air discharge
- Powder coating in many different colours, e.g. RAL CLASSIC
For further product information please click here
Operation
Once the IDH Induction unit is properly installed, follow these instructions to operate it:
- Ensure that the unit is connected to a suitable power source.
- Set the desired temperature and mode (heating or cooling) using the control system.
- Monitor the unit to ensure proper air discharge and temperature regulation.
- If using the condensate drip tray, periodically check and empty it as needed.
Maintenance
To maintain the IDH Induction unit and ensure its optimal performance, follow these maintenance guidelines:
- Regularly clean the unit’s air filters to remove dust and debris.
- Inspect the unit for any signs of damage or malfunction.
- If necessary, contact a qualified technician for repairs or servicing.
FAQ
-
Q: What is the purpose of the condensate drip tray?
A: The condensate drip tray is useful when the temperature temporarily falls below the dew point. It collects any condensation to prevent water damage. -
Q: Can I choose a custom color for the powder coating?
A: Yes, the IDH Induction unit is available with powder coating in many different colors, including those from the RAL CLASSIC color palette. Please consult the product information for available options.
References
- TROX UK - Industry leading manufacturers and suppliers of superior quality air conditioning, ventilation, fire and smoke protection systems, components and controls | TROX UK Ltd
- CONTACT | TROX UK Ltd
- Disclaimer | TROX UK Ltd
- Imprint | TROX UK Ltd
- OUR PRIVACY POLICY | TROX UK Ltd
- TROX UK's Terms and Conditions of Sale | TROX UK Ltd
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>