**OCULAR OC20-BA-22kW-A LTE Three Phase Universal Charging Station User Manual
**
How to charge – LTE
Starting a charging session
LTE socket model: Grab a charging cable and plug each end into their
respective ports.
LTE tethered model: Plug the attached charging cable into your car port.
Stopping a charging session
The charging sessions can be terminated either by the car or the charger.
- To stop charging via the car please consult your car manual.
- To stop charging via the charger, simply remove the charging plug from the port
Changing the charging speed
Before plugging the charging cable into the car, press the silver button on
the right side of the charger to adjust the charging speed.
How to program output current
Current Selection Mode
Press the silver button on the right hand side of the charger 3 times within
10 seconds This must be done within 60 seconds after restarting the charging
unit.
Please note that after 60 seconds from restarting, the charging unit will
continue with its normal booting process. Restart again if the button is not
pressed in this time.
Charging Current display
The LCD display will automatically switch to a new screen in this mode. It
will display the set output current. To change the set output current, press
the silver button until you reach the required Amperage. It will start at 32
Amps, and will go down to 6 Amps before returning back to 32 Amps.
The current will be changed in 1 Amp intervals.
Finalizing new charging limit
In order to finalize the new output current, once you have selected the
required Amperage in Step 2, leave the charger for 20 seconds until it
reboots.
Please note: the new output current will be set on the charger and will not
need to be reset each time the charger is rebooted.