OCULAR LTE Plus Type 2 Cable Installation Guide
- June 9, 2024
- OCULAR
Table of Contents
OCULAR LTE Plus Type 2 Cable
Ocular LTE Overview
Accessories of Tethered Model
Station Overview
Technical Parameters
Level 2 EV Charging Station
Phase Mode: Single Phase
Installation Method: Wall/Stand
Certificate: CE, TUV, RCM
IP Rating: IP66
Rated Voltage: 230VAC +/- 10%
Rated Current: 32A
Maximum Power: 7.2 kW
Ambient External Temp: -25°C ~ +55°C
Enclosure Material: ABS + PC alloy
Warranty: 2 years
Phase Mode: Three Phase
Installation Method: Wall/Stand
Certificate: CE, TUV, RCM
IP Rating: IP66
Rated Voltage: 400VAC +/- 10%
Rated Current: 32A
Maximum Power: 22 kW
Ambient External Temp: -25°C ~ +55°C
Enclosure Material: ABS + PC alloy
Warranty: 2 years
Instruction for Use
Make sure the wall box is connected to power
Connect the EV and the wall box with the EV charging cable
◆Hang the cable on the hook when it is not in use
Installation Guide
Note: Power cables must be crimped with suitable ferrules otherwise product warranty will be voided
Illustration of Screen and LED
-
Start-up screen (the version no. is for reference only)
-
Wait for inserting the plug
-
Wait for identification
-
Wait for the car to be ready
-
During charging process
-
During charging process pulling out the plug
-
Real-time power
-
Three Live Wire data
-
Charging Time
-
Power Consumption
-
Charging Icon
-
PCB Temperature
-
Emergency stop
-
Over Current
-
Over Temperature
-
Leakage protection
-
Short Current
| IDLE| CONNECTED| CHARGING| FINISHED| ERROR
---|---|---|---|---|---
Instruction of LED Status
| | | | |
Note :
The Ocular LTE plus will automatically restart when minor problems occur.
For serious failures, the system cannot automatically recover. In order to
remind user of this failure, the system will automatically countdown 10
seconds to restart.
Safety Warning
- Regularly check whether the charging station has visible damage.
- Make sure that all safety facilities are available at all times and are tested regularly to
- ensure they can operate normally. Visit ocularcharging.com.au for a yearly maintenance check according to Australian standards.
- If a ground fault occurs, it must be assumed that the cable carries voltage. Please confirm that there’s no high-voltage power in the system before inspecting the charging station.
- Persons who install and use charging stations must obey the principles and regulations mentioned to ensure personal and equipment safety.
- Before powering on the device, please confirm that the device is properly grounded to avoid unnecessary accidents.
- All tools’ unnecessarily exposed metal parts should be insulated to prevent them from touching the metal frame to avoid short circuits.
- Do not modify, retrofit, or change any part by yourself under any circumstances.
- To ensure the service life and stable operation of the charging station, the operating environment should be kept clean as possible with a relatively stable temperature and humidity. The charging station must not be used in a flammable environment or environments with volatile gas.
- Be sure to confirm that the input voltage, frequency, circuit breakers and other conditions of the device meet the specifications before the device is powered on
Maintenance
Ocular LTE is only recommended for use in residential applications and use outside of this area (i.e. for commercial application) is outside of warranty.
In order to ensure the normal service life of the charging station and reduce risk, maintenance must be performed every 12 months. The maintenance and installation of the equipment must be completed by a licensed electrician. Visit ocularcharging.com.au to book your service.
The product should be placed at an ambient temperature of -25C~+55C in relative humidity of no more than 95%. The air should not contain acids, alkalis, or other corrosive and explosive gases.
Ocular Charging Stations are subject to stringent quality inspections. From the day of purchase, any problem quality can be reflected to the dealer within two years.
Any direct damage or malfunction caused by neglect, incorrect use, installation, usage, repair by the users or natural damage are not covered by the warranty.
Welcome to your Ocular LTE PLUS
Scan here to check the quick installation guide.
WARNING! This product shall only be installed, repaired or serviced by an authorised electrician. All applicable local, regional and national regulations for electrical installations must be respected .
You can scan here to download EVSE Master APP.
Enjoy your daily charging.
Scan here for FAQs | Scan here for support documents |
---|---|
We have gathered all of the user manuals and technical documents here. And you will also find answers to the most common questions we receive from our private customers.
A smart choice for the environment!
How to charge – LTE Plus
-
Starting a charging session
LTE tethered model: Plug the attached charging cable into your car port. -
Stopping a charging session
The charging sessions can be terminated either by the car or the charger.
• To stop charging via the car please consult your car manual.
• To stop charging via the charger, simply remove the charging plug from the port
-
Changing the charging speed
Before plugging the charging cable into the car, press the silver button on the right side of the charger to adjust the charging speed.
Scan for a tutorial on the EVSE master app
CUSTOMER SUPPORT
MANUFACTURER
Ocular Charging
ocularcharging.com.au
sales@ocularcharging.com.au