TECHNICAL DATA

Application residential roads (internal), surrounding oce buildings, parks, pedestrians
Assembly on extension arms with ⌀ 42 x 30 mm ending
Colour inox / graphite
Ingress protection IP 66
Optical system PMMA optics
Material anodised aluminium alloy
Expected useful lifetime L90B10 – 100 000 h
CRI >70
Inrush current 21A / 225µs
Input voltage frequency 50/60Hz
Power factor ≥0.95
Number of LED 16
Control system Luminaire has the possibility to connect to an external control system via DALI interface (optionally via analog signal 1- 10V).

Code| Symbol| LED power| Luminaire power consumption| LED forward current| Colour temperature (CCT )| LEDs luminous flux| Luminaire luminous flux¹| Luminous ecacy ¹| Unit volume| Net weight
---|---|---|---|---|---|---|---|---|---|---
214930/6/…²| DROP LED 24| 24 W| 28 W| 500 mA| 5000 K| 4350 lm| 4150 lm| 148 lm/W| 0.041 m³| 4.9 kg

  1. tolerance +/- 5% due to LEDs accuracy
  2. symbol of chosen optical system eg. 214933/6/S is DROP LED 48 5000K with symetric optical system

DIRECTIVES AND STANDARDS

DIRECTIVES: 2014/35/UE (Official Journal of the UE L 96/357 29.03.2014), 2014/30/UE (Official Journal of the UE L 96/79 29.03.2014), 2011/65/UE, 2009/125/EC STANDARDS: –

CHARGING DISCHARGE FROM THE LED LUMINAIRE HOUSING

In order to efficient discharge the electrostatic charge from the housing of LED fitting installed on the pole from dielectric material (non-conductive) one of the following solutions is required:

  • functional grounding
  • LED luminaire with an additional protection device

TECHNICAL DRAWING

PHOTOMETRIC CURVES

POWER SYSTEM FUNCTIONS

Luminaire in standard has following functions of intelligent power supply:

  • Connection to outside control system by DALI interface (operation of analog signal 1-10V as an option),
  • Possibility of programming multistage dimming of luminaire, up to 5 intervals in the range of from 10 to 100% of nominal power,
  • Temperature protection of LED module (from overheating) in case of unintentional luminaire operation during the,
  • Regulation of power / luminous ux – the option of setting another value than the catalogue in the range of 30-100% of nominal one,

ACCETABLE QUANTITY OF LUMINAIRES ON ONE CIRCUIT

Overcurrent switches MCB type B or C

Luminaire| Typ| 2A| 4A| 6A| 10A| 16A| 20A| 25A
---|---|---|---|---|---|---|---|---
DROP LED 48| B| 1| 2| 4| 6| 12| 12| 15
| C| 1| 4| 6| 10| 17| 20| 26
DROP LED 24, 36| B| 3| 6| 10| 16| 26| 32| 40
| C| 3| 10| 16| 27| 44| 54| 67

Fuse – type gG and GL

Luminaire| 2A| 4A| 6A| 10A| 16A| 20A| 25A
---|---|---|---|---|---|---|---
DROP LED 48| 0| 4| 8| 11| 22| 31| 44
DROP LED 24, 36| 1| 10| 19| 25| 50| 68| 97

Zakład Produkcji Sprzętu Oświetleniowego „ROSA” Sp. z o.o.
43-109 Tychy, ul. Strefowa 1 tel. +48 32 73 88 901