TECHNICAL DATA

Application urban roads, residential roads (internal), pedestrians, parkings
Assembly on extension arms with ⌀ 60 x 100 mm ending
Colour inox / black
Ingress protection IP 66 for the optical part and the driver
Optical system PMMA optics, interchangeable LED module
Material anodised aluminium alloy
Expected useful lifetime L90B10 – 100 000 h
CRI >70
Inrush current 43A / 260µs
Input voltage frequency 50/60Hz
Power factor ≥0.95
Number of LED 24
Control system Luminaire has the possibility to connect to an external

control system via DALI interface (optionally via analog signal 1- 10V).
Code| Symbol| LED power| Luminaire power consumption| LED forward current| Colour temperature (CCT)| LEDs luminous flux¹| Luminaire luminous ux¹| Luminous ecacy¹| Unit volume| Net weight
---|---|---|---|---|---|---|---|---|---|---
2210033/6/…²| COSMO LED 48| 48 W| 55 W| 700 mA| 5000 K| 8650 lm| 7800 lm| 141 lm/W| 0.073 m³| 10.2 kg

  1. tolerance +/- 5% due to LEDs accuracy
  2. symbol of chosen optical system eg. 2210035/6/T2 is COSMO LED 72 5000K with T2 optical system

DIRECTIVES AND STANDARDS

DIRECTIVES: 2014/35/UE (Official Journal of the UE L 96/357 29.03.2014), 2014/30/UE (Official Journal of the UE L 96/79 29.03.2014), 2011/65/UE, 2009/125/EC STANDARDS:

CHARGING DISCHARGE FROM THE LED LUMINAIRE HOUSING

In order to efficient discharge the electrostatic charge from the housing of LED fitting installed on the pole from dielectric material (non-conductive) one of the following solutions is required:

  • functional grounding
  • LED luminaire with an additional protection

TECHNICAL DRAWING

Dimensions

PHOTOMETRIC CURVES

COSMO LED 48

Dimensions
Dimensions
Dimensions
Dimensions

POWER SYSTEM FUNCTIONS

Luminaire in standard has following functions of intelligent power supply:

  • Connection to outside control system by DALI interface (operation of analog signal 1-10V as an option),
  • Possibility of programming multistage dimming of luminaire, up to 5 intervals in the range of from 10 to 100% of nominal power,
  • Temperature protection of LED module (from overheating) in case of unintentional luminaire operation during the,
  • Regulation of power / luminous flux – the option of setting another value than the catalogue in the range of 30-100% of nominal one,

ACCETABLE QUANTITY OF LUMINAIRES ON ONE CIRCUIT

Overcurrent switches MCB type B or C

Luminaire| Typ| 2A| 4A| 6A| 10A| 16A| 20A| 25A
---|---|---|---|---|---|---|---|---
COSMO LED 48, 60, 72W| B| 1| 2| 4| 6| 10| 12| 15
C| 1| 4| 6| 10| 17| 20| 25

Fuse – type gG and GL

Luminaire| 2A| 4A| 6A| 10A| 16A| 20A| 25A
---|---|---|---|---|---|---|---
COSMO LED 48, 60, 72W| 0| 4| 8| 11| 22| 31| 44

Zakład Produkcji Sprzętu Oświetleniowego „ROSA” Sp. z o.o. 43-109 Tychy, ul. Strefowa 1 tel. +48 32 73 88 901