ROSA DROP Led 36 Owner’s Manual
- June 12, 2024
- ROSA
Table of Contents
ROSA DROP Led 36
Product Information
Product Name: DROP LED 36
Technical Data:
- Application: Residential roads (internal), surrounding office buildings, parks, pedestrians
- Assembly: On extension arms with 42 x 30 mm ending
- Colour: Inox / Graphite
- Ingress Protection: IP 66
- Optical System: PMMA optics
- Material: Anodised aluminium alloy
- Expected Useful Lifetime: L90B10 – 100,000 h
- CRI: >80
- Inrush Current: Input voltage frequency 50/60Hz
- Power Factor: 0.95
- Number of LED: 16
- Control System: Luminaire has the possibility to connect to an external control system via DALI interface (optionally via analog signal 1-10V)
- Code: Symbol LED power Luminaire power consumption LED forward current Colour temperature (CCT) LEDs luminous Luminaire luminous
- Tolerance: +/- 5% due to LEDs accuracy
Product Usage Instructions
- Step 1: Ensure functional grounding and LED luminaire with an additional protection device are in place for efficient discharge of electrostatic charge from the housing.
- Step 2: Install the luminaire on extension arms with 42 x 30 mm ending.
- Step 3: Connect the luminaire to an external control system via DALI interface or analog signal 1-10V (optional).
- Step 4: Use appropriate overcurrent switches (MCB type B or C) for acceptable quantity of luminaires on one circuit. Refer to the provided table for the number of luminaires based on different amperage ratings.
Note: For detailed technical drawings and photometric curves, please refer to the product manual or visit the manufacturer’s website at www.rosa.pl.
TECHNICAL DATA
- Application residential roads (internal), surrounding office buildings, parks, pedestrians
- Assembly on extension arms with ⌀ 42 x 30 mm ending
- Color inox/graphite
- Ingress protection IP 66
- Optical system PMMA optics
- Material anodised aluminum alloy
- Expected useful lifetime L90B10 – 100 000 h
- CRI >80
- Inrush current 21A / 225μs
- Input voltage frequency 50/60Hz
- Power factor ≥0.95
- Number of LED 16
- Control system Luminaire has the possibility to connect to an external control system via DALI interface (optionally via analog signal 1- 10V).
- tolerance +/- 5% due to LEDs accuracy
- symbol of chosen optical system eg. 214933/6/S is DROP LED 48 5000K with symetric optical system
DIRECTIVES AND STANDARDS
DIRECTIVES:
2014/35/UE (Official Journal of the UE L 96/357 29.03.2014), 2014/30/UE
(Official Journal of the UE L 96/79 29.03.2014), 2011/65/UE, 2009/125/EC
STANDARDS:
–
CHARGING DISCHARGE FROM THE LED LUMINAIRE HOUSING
- In order to efficient discharge the electrostatic charge from the housing of LED fitting installed on the pole from dielectric material (non-conductive) one of the following solutions is required:
- functional grounding
- LED luminaire with an additional protection device
TECHNICAL DRAWING
PHOTOMETRIC CURVES
DROP LED 36
POWER SYSTEM FUNCTIONS
Luminaire in standard has following functions of intelligent power supply:
- Connection to outside control system by DALI interface (operation of analog signal 1-10V as an option),
- Possibility of programming multistage dimming of luminaire, up to 5 intervals in the range of from 10 to 100% of nominal power,
- Temperature protection of LED module (from overheating) in case of unintentional luminaire operation during the,
- Regulation of power / luminous flux – the option of setting another value than the catalogue in the range of 30-100% of nominal one,
ACCETABLE QUANTITY OF LUMINAIRES ON ONE CIRCUIT
Zakład Produkcji Sprzętu Oświetleniowego „ROSA” Sp. z o.o.
43-109 Tychy, ul. Strefowa 1 tel. +48 32 73 88 901
www.rosa.pl
Updated at: 28-06-2023
Read User Manual Online (PDF format)