ROSA OW LED 36 LED Lamp For Pedestrian Crossings Instruction Manual
- June 16, 2024
- ROSA
Table of Contents
ROSA OW LED 36 LED Lamp For Pedestrian Crossings Instruction Manual
TECHNICAL DATA
- Application: urban roads, residential roads (internal), parks, pedestrians, parkings
- Assembly: on extension arms, wall brackets, columns with extension arms with ⌀ 42 x 40 mm ending
- Colour: black
- Ingress protection: IP 66
- Material: body and cap – anodised aluminium formed sheet metal
- Operating temperature range: from -40°C to +55°C
- Expected useful lifetime: L90B10 – 100 000 h
- CRI: >70
- Inrush current: 21A / 225µs
- Input voltage frequency: 50/60Hz
- Power factor: ≥0.95
- Number of LED: 12
- Control system: Luminaire has the possibility to connect to an external control system via DALI interface (optionally via analog signal 1- 10V).
Symbol
Code| Symbol| LED power| Luminaire power consumptio| LED forward current|
Colour temperature (CCT)| LEDs luminous flux¹| Luminaire luminous ux| Luminous
ecacy¹| Unit volume| Net weight
---|---|---|---|---|---|---|---|---|---|---
2109032/4/…²| OW LED 36| 36 W| 40 W| 1000 mA| 4000 K| 6000 lm| 5350 lm| 134
lm/W| 0.16 m³| 4.6 kg
- tolerance +/- 5% due to LEDs accuracy
- symbol of chosen optical system eg. 2109033/6/T2 is OW LED 48 5000K with T2 optical system
DIRECTIVES AND STANDARDS
DIRECTIVES: 2014/35/UE (Official Journal of the UE L 96/357 29.03.2014),
2014/30/UE (Official Journal of the UE L 96/79 29.03.2014), 2011/65/UE,
2009/125/EC
STANDARDS: –
CHARGING DISCHARGE FROM THE LED LUMINAIRE HOUSING
In order to efficient discharge the electrostatic charge from the housing of LED fitting installed on the pole from dielectric material (non-conductive) one of the following solutions is required:
- functional grounding
- LED luminaire with an additional protection device
TECHNICAL DRAWING
OW LED
OW LED Z KLOSZEM
PHOTOMETRIC CURVES
POWER SYSTEM FUNCTIONS
Luminaire in standard has following functions of intelligent power supply:
- Connection to outside control system by DALI interface (operation of analog signal 1-10V as an option),
- Possibility of programming multistage dimming of luminaire, up to 5 intervals in the range of from 10 to 100% of nominal power,
- Temperature protection of LED module (from overheating) in case of unintentional luminaire operation during the,
- Regulation of power / luminous flux – the option of setting another value than the catalogue in the range of 30-100% of nominal one,
ACCETABLE QUANTITY OF LUMINAIRES ON ONE CIRCUIT
KLOSZE DO OPRAWY OW LED
Zakład Produkcji Sprzętu Oświetleniowego „ROSA” Sp. z o.o.
43-109 Tychy, ul. Strefowa 1 tel. +48 32 73 88 901
www.rosa.pl