Oase PondoVac 5 Vaccuum Tennessee Water Gardens Instructions
- June 15, 2024
- Oase
Table of Contents
- Oase PondoVac 5 Vaccuum Tennessee Water Gardens
- Product Information
- Product Usage Instructions
- FAQ
- Safety information
- Safe operation
- Intended use
- Scope of delivery
- Unit overview
- Opening/closing the tank
- Assembling the vacuum cleaner
- Installation and connection
- Operation
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Oase PondoVac 5 Vaccuum Tennessee Water Gardens
Product Information
Specifications
- Model: PondoVac 5 HU
- Languages: DE, EN, FR, NL, ES, PT, IT, DA, NO, SV, FI, PL, CS, SK, SL, HR, RO, BG, UK, ZH, RU
Product Usage Instructions
Commissioning
To commission the PondoVac 5 HU, follow these steps:
- Mount the output.
- Mount the input.
- Attach the suction hose to the input.
Safety Instructions
Before using the product, please read and follow these safety instructions:
- Disconnect all electrical devices in the water from the power supply.
- Ensure safe operation.
Electrical Connection
To connect the PondoVac 5 HU to an electrical supply:
- Refer to the electrical connection section in the manual for
detailed instructions.
Safe Operation
To ensure safe operation of the PondoVac 5 HU:
- Follow the safety instructions provided in the manual.
- Do not exceed the operating current of 30 mA.
- Only use the product for its intended use.
Scope of Delivery
The following items are included in the scope of delivery:
- 1 x extension tube, transparent
FAQ
Q: Where can I download the full manual?
A: You can download the full manual in PDF format from our website at www.oase.com/manual.
Q: How do I assemble the vacuum cleaner?
A: To assemble the vacuum cleaner, follow these steps:
- Release the locking clips to open the tank. Insert the wheels into the wheel bush and push them until they lock into place.
- Check the correct seating of the adapter with non-return valve before fitting the outlet.
- Refer to the manual for further instructions.
Q: What should I do before working on the unit?
A: Before working on the unit, make sure to disconnect it from the mains to avoid the risk of electric shock.
Original manual. This manual belongs with the unit and must always be passed on together with the unit.
WARNING
- Disconnect all electrical devices in the water from the power supply before reaching into the water. Otherwise there is a risk of severe in-juries or death by electrocution.
- This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of expe-rience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow chil-dren to carry out cleaning and user maintenance under supervision.
Further instructions in a PDF format are available for download online at: www.oase.com/manual
The following additional topics are addressed in the operating manual:
- Product properties, function description
- Symbols on the unit
- Cleaning and maintenance, storage/winter-proofing, malfunction repair
- Technical data, wear parts, spare parts, disposal
Safety information
Electrical connection
-
Special regulations apply for electrical installation in outdoor spaces. Only a qualified electri-cian may perform the electrical installation.
The qualified electrician has the necessary professional training, knowledge and experience to perform electrical installation in outdoor spaces. The electrician can detect potential dangers and knows how to adhere to regional and national standards, regulations and direc-tives.
For your own safety, please consult a qualified electrician. -
Only connect the unit if the electrical data of the unit and the power supply match.
-
Only plug the unit into a correctly installed outlet.
-
The device is to be supplied through a residual current device (RCD) having a rated residual op-erating current not exceeding 30 mA.
-
Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
-
Protect open plugs and sockets from moisture.
Safe operation
- Do not operate or leave the unit in the rain.
- Minimum safety distance between the unit and the water: 2 m.
- Never operate the unit if either the electrical cables or the housing are defective!
- Do not carry or pull the unit by its electrical cable.
- Route cords/hoses/lines in a way that they are protected against damage, and ensure that they do not present a tripping obstacle.
- Only open the unit housing or its attendant components, when this is explicitly required in the operating instructions.
- Only execute work on the unit that is described in this manual. If problems cannot be over-come, please contact an authorised customer service point or, when in doubt, the manufac-turer.
- Only use original spare parts and accessories for the unit.
- Never carry out technical modifications to the unit.
- Operate the unit only when there are no people in the water.
Intended use
Only use the product described in this manual as follows:
- For pond sludge removal.
- For cleaning ponds, swimming ponds and pools.
- Only operate the vacuum cleaner with the debris collection bag in place.
- While adhering to the technical specifications.
The following restrictions apply to the unit:
- Never run the unit without water.
- Never use the unit with fluids other than water.
- The debris/dirt must contain at least 20 % water.
- Only operate with water at a water temperature of +4 °C to +35 °C.
- Do not use for industrial purposes.
Scope of delivery
The parts included in the scope of delivery are inside the container and have to be removed first!
A
-
1× multi-purpose vacuum cleaner PondoVac 5
-
1× suction hose with handle
-
1 × drain hose
-
1 × extension tube
-
1 x extension tube, transparent
-
1 × surface nozzle
For cleaning large, smooth surfaces -
1× wet suction nozzle
For removing dirty or residual water for operation as a wet vacuum cleaner -
1× string algae nozzle
For separating and removing string algae -
1× universal nozzle
For removing pond sludge without vacuuming up the pond gravel -
1× brush nozzle:
For removing stubborn dirt -
1× operating instructions
-
2× wheel
-
1× Storz fixed coupling type C
-
1× inlet distributor
-
1× debris collection bag
-
1× Velcro tape for debris collection bag
-
1× fine filter bag
Unit overview
B
-
Transport handle
-
Transport brace
-
Locking screw for fastening the transport brace
-
Power switch
For switching the vacuum cleaner on and off -
Vacuum head
-
Locking clips (6 ×)
-
Plug connector (designed to prevent misconnection) for connecting the pump
-
Foam filter
Protects the electronics in the vacuum head from the ingress of dirt particles. -
Filter support basket
The integrated float protects the electronics from the ingress of water if the maximum water level is exceeded. -
Power cable with power plug
-
Wheel (2×)
-
Outlet (pressure socket) with Storz coupling type C
-
Pump base
-
Discharge pump
-
Container
-
Adapter with non-return valve
The non-return valve prevents water running back via the discharge hose. -
Debris collection bag
-
Inlet (suction socket)
Opening/closing the tank
WARNING
Risk of severe injuries or death by electric shock.
Disconnect the unit from the mains before you start working on it.
How to proceed:
C
-
Release the locking clips.
To do this, grip the clips from underneath and pull upwards. -
Lift off the vacuum head and the adapter ring.
The vacuum head and adapter ring can be removed separately.
The plug connector for the discharge pump does not need to be disconnected. -
Assemble the parts in the reverse order and fasten with the locking clips.
Ensure that the parts are precisely aligned in relation to each other.
Ensure that the seal on the adapter ring is correctly seated so that it is not damaged during assembly.
Assembling the vacuum cleaner
Fitting the wheels
How to proceed:
D
- Insert the wheel into the wheel bush.
- Firmly push the wheel until it locks into place.
Fitting the outlet
Prerequisite: The tank is open. (→ Opening/closing the tank) How to proceed:
E
-
Check the correct seating of the adapter with non-return valve.
Ensure that the adapter is locked into place in the tank wall. -
Screw the Storz coupling type C onto the outlet and hand-tighten.
Fitting the inlet
Prerequisite: The tank is open. (→ Opening/closing the tank)
How to proceed:
F
-
Insert the intake distributor into the opening.
Guide the pins on the intake distributor through the notches of the opening. -
Twist the intake distributor to lock it into place (bayonet closure).
Ensure that the outlet of the intake distributor in the tank is angled downwards. -
Fit the debris collection bag onto the intake distributor in the tank.
Ensure that the elastic of the debris collection bag is seated in the groove of the intake dis-tributor.
Secure the debris collection bag with the Velcro tape.
Installation and connection
G
WARNING
Risk of severe injuries or death by electric shock.
- Install the unit at a distance of at least 2 m from the water.
- Place the unit on horizontal, firm ground to prevent it from tipping over.
NOTE
The vacuum cleaner can be set up and operated in a position that is up to 0.3 m lower than the water level. However, when the vacuum cleaner is switched off, the water will automatically flow through the tank while the suction hose remains in the pond/pool. This will empty the pond or pool.
Always take the suction hose out of the pool/pond when the vacuum cleaner is switched off.
Adjusting the transport brace
How to proceed
H
- Undo the locking screw.
- Move the transport brace into the desired position.
- Hand-tighten the locking screw.
Connecting the hoses and nozzles
The following conditions must be met:
- Allow the dirty water to drain out into a drain or far enough away from the pond to ensure that it cannot flow back into the pond.
- Completely unwind the power and extension cable.
Ensure that the cables are not bundled together or coiled up.
How to proceed
I
- Attach the discharge hose to the outlet and twist it clockwise (bayonet closure).
- If only coarse dirt particles >1 mm (e.g. leaves or hair) are to be removed, you can allow the waste water to flow back into the pond / pool via the fine filter bag.
- Do not allow muddy water to flow back into the pond / pool.
- Attach the suction hose to the inlet.
- Fit extension tubes and the desired nozzle to the suction hose with handle.
- Universal nozzle: For removing pond sludge without vacuuming up the pond gravel.
- Algae nozzle: For separating and removing string algae.
- Brush nozzle: For removing stubborn dirt.
- Surface cleaning nozzle: For cleaning large, smooth surfaces.
- Wet suction nozzle: For removing dirty or residual water for operation as a wet vacuum cleaner
The more tubes are used, the higher the tube frictional resistance. This leads to a reduction of the suction capacity.
Operation
NOTE
The unit and seals are subjected to excessive strain if the vacuum cleaner is moved when the tank is full.
Empty the tank before moving the vacuum cleaner.
Set up the vacuum cleaner on ground that is not much higher than the water level to avoid impairing the suction capacity.
- Switch on the vacuum cleaner at the power switch.
- The suction power can be adjusted with the slide in the suction hose handle.
- To increase the suction: Move the slide forwards.
- To reduce the suction: Move the slide backwards.
- Clean the vacuum cleaner after each use.
- Recommendation: Vacuum up clean water before cleaning. This will wash out the dirt particles.
OASE GmbH Tecklenburger Straße 161 48477 Hörstel | Germany
+ 49 (0) 5454 80-0
+ 49 (0) 5454 80-9353
info@oase.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>