Original manual. This manual belongs to the unit and must always be passed on together with the unit. EN WARNING

WARNING

  • This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.

Further instructions in a PDF format are available for download online at: www.oase.com/manual
The following additional topics are addressed in the operating manual:

http://www.oase.com/manual

  • Symbols on the unit
  • Changing the activation pressure
  • Shut-down
  • Cleaning and maintenance, storage/winter-proofing, malfunction repair
  • Technical data
  • Disposal

Safety information

Electrical connection

  • Special regulations apply for electrical installation in outdoor spaces. Only a qualified electrician may perform the electrical installation.
    – The qualified electrician has the necessary professional training, knowledge, and experience to perform electrical installation in outdoor spaces. The electrician can detect potential dangers and knows how to adhere to regional and national standards, regulations, and directives.
    – For your own safety, please consult a qualified electrician.

  • Only connect the unit if the electrical data of the unit and the power supply match.

  • Only plug the unit into a correctly installed outlet. Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.

  • Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).

  • Protect open plugs and sockets from moisture.

Safe operation

  • Do not use the unit, if electrical lines or the housing are damaged.
  • If a power connection cable is damaged, have it immediately replaced by OASE, an authorized customer service, or a qualified electrician to prevent electric shock.
  • Do not carry or pull the unit by its power cable.
  • Route lines in such a way that they are protected from damage and do not present a tripping hazard.
  • Never carry out technical changes to the unit.
  • Only carry out work on the unit that is described in this manual.
  • Only use original spare parts and accessories..

Intended use
Only use the product described in this manual as follows:

  • Automatic cut-in and switch-off of a water pump (pressure pump) when water is taken from a connected appliance.

  • While adhering to the technical specifications.
    The following restrictions apply to the unit:

  • Not suitable for pumps with an integrated automatic control system.

  • Do not connect to the drinking water supply.

  • Not suitable for drinking water.

  • Do not use it for commercial or industrial purposes.

  • Do not use it in conjunction with chemicals, foodstuff, or easily flammable or explosive substances.

Product Description

Overview

1 Power supply for the pump
2 Outlet AG
3 Power connection cable
4 Pressure gauge
5 Inlet (can be rotated)
6 Adapter
7 START button
8 Dry run indicator lamp, red
9 Operating indicator lamp, green

Installation and connection

NOTE
Excessive water pressure in the system will damage the unit.

  • Ensure that the distance from the highest water withdrawal point does not exceed 15 m.
  • Ensure that the system pressure does not exceed 10 bar.
  • Adhere to the maximum permissible pump pressure. It may be less than 10 bars.

 A
The unit can be connected horizontally or vertically at any point between the pressure connection of a garden pump, deep good pump, or submersible pressure pump and the first water withdrawal point (e.g. washing machine).

  •  Recommendation: Fit directly to the pressure connection of the pump. Use an adapter.

How to proceed:
 B

  1. Screw the adapter onto the pump.
    – Ensure that the O-ring is correctly seated.

  2. Screw the unit onto the adapter.
    – When fitting, ensure that the arrow on the cover and the outlet of the unit point in the direction of the water flow.

  3. Connect the unit to the downstream line.

NOTE
Ensure that all connection lines are completely leak-tight, as leaking lines can impair the function of the system and lead to damage.

  • Use a suitable sealant to seal the threads of the lines and the connection to the pump.
  • Overtightening of plastic screw connections can lead to damage. Do not apply excessive force.

Operation

Starting up the unit
It is necessary to fill the pump and expel the air from the suction line before use. It can take
several minutes to expel air from the suction line.

How to proceed:

  • Completely fill the pump and suction line. (→ Pump operating manual)
    1. Connect the power plug of the pump with the socket of the ProMax Garden Automatic Switch.
    2. Plug the power plug of the ProMax Garden Automatic Switch into the socket.
    – The indicator lamp ON lights up green.
    – The unit is now operational.
    3. Switch on the pump and press the START PUMP button on the ProMax Garden Automatic Switch.
    – The ProMax Garden Automatic Switch activates the pump for approx. 15 seconds.
    4. After the automatic shut-down of the pump, open the highest water withdrawal point.
    – The ProMax Garden Automatic Switch switches the pump back on again.
    5. Close the water withdrawal point when water flows out evenly.
    – Start-up is complete.

  • If no water is pumped:
    − Let the pump run for longer than the time determined by ProMax Garden Automatic Switch. To do so, hold the START PUMP button until the pump priming process is complete and water is pumped.
    − If no water is pumped even after approximately one minute: Disconnect ProMax Garden Automatic Switch from the power grid and repeat the start-up process.

Interruption of operation and restarting
If the pump runs dry or there is insufficient water,

  • the ProMax Garden Automatic Switch will switch off the pump,
  • the indicator lamp ERROR lights up red.
  • automatic activation of the pump will be prevented.

To restart the operation:

  • Eliminate the cause of the shutdown.
  • Press the START PUMP button.

OASE GmbH
Tecklenburger Straße 161
48477 Hörstel | Germany
+49 (0) 5454 80-0
+49 (0) 5454 80-9353
****info@oase.com

Documents / Resources

| Oase 43362-GA ProMax Garden Automatic Switch [pdf] Instruction Manual
43362-GA ProMax Garden Automatic Switch, 43362-GA, ProMax Garden Automatic Switch, Garden Automatic Switch, Automatic Switch, Switch
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals