INTERTHERM E3EB-010-H Series Downflow Upflow Electric Furances Owner’s Manual
- June 15, 2024
- Intertherm
Table of Contents
TECHNICAL
SPECIFICATIONS
E3EB-xxx-HSeries
Downflow, Upflow Electric Furnaces
The E3 Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate reliability and low maintenance. Units may be installed free standing in a utility room or enclosed in an alcove or closet. E3 Series furnaces are A/C ready, with multiple blower combinations for cooling requirements.
FEATURES and BENEFITS
- Choice of Air Conditioning Options: From 2 to 5 tons A/C ready.
- Easy Open Door: Secures the door firmly for transit, yet allows easy removal for access.
- Effective Air Filter: Universal disposable filter is readily available and simple to replace.
- Nichrome Heating Elements: Provide long lasting, efficient heating.
- Appliance Quality Door: Protects against rust and other corrosion. Baked enamel finish allows for easy cleaning.
- Fully Insulated Cabinet: Insures minimized heat loss and quiet operation.
- Safety and Dependability: Auto reset controls protect unit’s electrical circuitry and helps ensure trouble free performance. Built in circuit breakers for extra safety.
- Adaptable: Unit can be adapted to provide dependable heating in either downflow or upflow mode.
- Versatile: Works with self-contained or split system air conditioners or heat pumps.
MODELIDENTIFICATION
-
Product Type
E – Electric Furnace -
Generation
3 – Third Series -
Product Identifier
EB – A/C Blower Equipped Relay -
Electrical Code
H – 240-1-60 -
Primary Capacity
010 – 10 kw 012 – 12 kw
015 – 15 kw 017 – 17 kw
020 – 20 kw 023 – 23 kw
Furnace Parts Identification
- Indoor Coil (optional)
- Coil Air Filters (used with indoor coil)
- Furnace Air Filter ( NOT used with coil air filters)
- Blower
- Circuit Breakers
- Data Label
- Control Panel Cover (left)
- Control Panel Cover (right)
Optional Accessories
Upflow Coil Cabinet
- Cabinet Insulation
Upflow Stand
UNIT SPECIFICATIONS
Electric Furnace Models|
E3EB
---|---
010H
| 012H| 015H| 017H| 020H| 023H|
023H 5-Ton
Rated Heating Output, Btuh (see note 1)|
35,000
| 41,000| 53,000| 57,000| 70,000| 75,000|
75,000
Watts (Total kw, Heating Elements and Blower)| 10.4| 12.0| 15.4| 16.6| 20.4| 22.0|
22.0
Supply Voltage|
240 Volts/60Hz/1-Phase
Heating Elements, No.(Total kw)|
2 (10.0)
| 2 (11.6) | 3 (15.0) | 3 (16.2)| 4 (20.0) | 4 (21.6)|
4 (21.6)
Blower Wheel Size|
10.5″ Dia, 8″ Wide
|
11” Dia., 8” W
Motor Speed, H.P. Rating, Amps|
4 Speed, 1/3 HP, 2.9
|
4 Spd, 3/4HP 3.8 Amps
Test ESP, in. w.c. Max|
0.3
Optional Cooling Available with factory installed blower|
2.0 – 4.0 Ton
|
2.0 – 5.0 Ton
Optional Heat Pump Available with factory installed blower |
2.0 – 4.0 Ton
Air Filter (Standard)|
16” x 20” x 1” (nominal)
Furnace Dimensions|
Width-20” (508mm), Height-29” (737mm) (see note 2), Depth-24 1/2” (623mm)
- Heating output rated at listed voltage. For outputs at voltages other than 240V, multiply Btuh rating by the following factors: x 0.92 (230V), x 0.84 (220V), x 0.75 (208V)
- Height is 56″ with return air grille installed, 58″ with coil cabinet and 72″ with coil cabinet and upflow stand.
ELECTRICALSPECIFICATIONS
*Model Number E3E()**
| Supply Circuit| Total Amperes| Maximum Over-current Rating|
Minimum Circuit Ampacity
---|---|---|---|---
-010H
|
Single
| 44.6| 60| 56
-012H| Single| 51.2| 70|
64
Dual “A”
| 27.1| 40| 34
Dual “B”| 24.2| 30|
30
-015H
|
Single
| 65.4| 90| 82
Dual “A” | 44.6| 60|
56
Dual “B”
| 20.8| 30| 26
-017H
| Single| 70.4| 90|
88
Dual “A”
| 47.9| 60| 60
Dual “B”| 22.5| 30|
28
-020H
|
Single
| 86.2| 125| 108
Dual “A” | 44.6| 60|
56
Dual “B”
| 41.7| 60| 52
-023H
| Single| 93.8| 125|
117
Dual “A”
| 45.5| 60| 57
Dual “B”| 48.0| 60|
60
Replacement furnace for E2E(*)-015HB
Blower Performance
4-Ton Blower with Coil and Coil Filters, @ 0.3” ESP
Pin No.| Speed|
CFM
1
| Low| 880
2| Med.-Low|
1170
3
| Med.-High| 1310
4| High|
1460
5-Ton Blower, with Coil and Coil Filters, @ 0.3” ESP
Pin No.
| Speed| CFM
1 | Low|
990
2
| Med.-Low| 1320
3| Med.-High|
1620
4
| High|
1790
Anticipator Settings
Furnace Model
|
Thermostat Anticipator Setting
---|---
010, 012
| 0.2
015, 017, 020, 023 |
0.4
Clearances
ALL MODELS | CLOSET | ALCOVE |
---|---|---|
Front ‡ |
6”
|
18”
Back|
0”
|
0”
Sides|
0Ӡ
|
0Ӡ
Top and Sides of Duct|
0”
|
0”
Bottom of Duct|
0”
|
0”
‡ Service Clearance
† For upflow application using upflow stand, 1″ minimum per side
AIRFLOW DATA
E3EB (010, 012, 015, 017, 020, 023) H
Coil
|
High
| Med High| Med Low| Low
4-ton | No Coil | 3.5 ton| No Coil| 3-ton| No Coil| 2.5-ton|
None
Static (ESP) in W.C.
|
0.1
| 1559| 1503| 1389| 1362| 1227| 1203| 923| 885
0.2| 1506| 1458| 1352| 1330| 1208| 1174| 906|
863
0.3
| 1460| 1414| 1310| 1291| 1170| 1146| 880| 831
0.4| 1401| 1352| 1260| 1241| 1136| 1103| 845|
798
0.5
| 1333| 1282| 1198| 1179| 1086| 1055| 805| 758
0.6| 1251| 1208| 1133| 1113| 1027| 996| 757|
707
E3EB 023H-5 TON and 5 ton accessory blower
Coil
| High| Med High| Med Low|
Low
5-ton
| No Coil | 5-ton | No Coil | 5-ton | No Coil | 5-ton |
No Coil
Static (ESP) in W.C.
|
0.1
| 1911| 1886| 1709| 1679| 1394| 1373| 1054| 1032
0.2| 1860| 1821| 1663| 1630| 1359| 1333| 1027|
1004
0.3
| 1790| 1768| 1620| 1585| 1320| 1296| 880| 970
0.4| 1741| 1700| 1563| 1526| 1279| 1252| 952|
928
0.5
| 1671| 1643| 1511| 1473| 1229| 1201| 912| 884
0.6| 1613| 1584| 1444| 1400| 1182| 1147| 864|
824
ACCESSORIES
Description
|
Part Number
---|---
Blower, 2-4 Ton|
902993
Blower, 5 Ton|
902985
Heating Thermostat Intertherm (12 Pac)|
903188 (903182)
Heating Thermostat Miller (12 Pac)|
903189 (903183)
Thermostat Sub-Base|
914146
Heating/Cooling Thermostat CM65 Intertherm/Miller (12 Pac)|
903992 (903993)
Heating/Cooling Thermostat GE Intertherm (12 Pac)|
903192 (903186)
Heating/Cooling Thermostat GE Miller (12 Pac)|
903193 (903187)
Automatic Damper for AC or HP Package Unit |
901083
“VEE” Box Adapters (10”) – 5 / carton|
901985
Duct Connector 10” Dia. x 6” Long – 6 / carton |
902926
“VEE” Box Adapters (12”) – 5 / carton|
902149
Single Wide Fitting Kit (12”) |
911468A
Double Wide Fitting Kit (12”)|
911469A
Single Wide Fitting Kit (14”)|
914957
Double Wide Fitting Kit (14”)|
914956
Y-Fitting (12”)|
911470
Y-Fitting (14”)|
917195
Fan Delay Kit (TDR)|
911758
Top Grille/Frame|
902989
Top Grille/Frame (4 pack)|
903000
Wall Mount Top Grille (10 pack)|
902988
Coil Cabinet Upflow|
902976
Coil Cabinet Downflow (Front return)|
903891
Upflow Stand|
904620
Coil Cabinet, Downflow (Front and top return)|
904067
ACCESSORYKITS
Vent Kits|
Part Number
---|---
Soffit Air Inlet (for VentilAire III only)|
917201A
VentilAire III – Sloped 3/12|
914098
VentilAire IV – Sloped 3/12|
914229
Plenum Connectors|
Part Number
---|---
11.25 x 13.50 x 0.88 12 / carton|
901987A
11.25 x 13.50 x 2.00 12 / carton|
901988A
11.25 x 13.50 x 4.25 6 / carton|
901989A
11.25 x 13.50 x 6.25 6 / carton|
901990A
11.25 x 13.50 x 8.25 4 / carton|
901991A
11.25 x 13.50 x 10.25 3 / carton|
901992A
11.25 x 13.50 x 12.25 3 / carton|
901993A
11.25 x 13.50 x 6.25 24 / carton|
902681A
GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (1 /2015)
936B-1114 (Replaces 936B-0214) www.intertherm.net
Trademark Intertherm® used under license.© Nortek Global HVAC, LLC. All Rights Reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>