INTERTHERM E3EB-010-H Series Downflow Upflow Electric Furances Owner’s Manual

June 15, 2024
Intertherm

TECHNICAL

SPECIFICATIONS


E3EB-xxx-HSeries

Downflow, Upflow Electric Furnaces

The E3 Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate reliability and low maintenance. Units may be installed free standing in a utility room or enclosed in an alcove or closet. E3 Series furnaces are A/C ready, with multiple blower combinations for cooling requirements.

FEATURES and BENEFITS
  • Choice of Air Conditioning Options: From 2 to 5 tons A/C ready.
  • Easy Open Door: Secures the door firmly for transit, yet allows easy removal for access.
  • Effective Air Filter: Universal disposable filter is readily available and simple to replace.
  • Nichrome Heating Elements: Provide long lasting, efficient heating.
  • Appliance Quality Door: Protects against rust and other corrosion. Baked enamel finish allows for easy cleaning.
  • Fully Insulated Cabinet: Insures minimized heat loss and quiet operation.
  • Safety and Dependability: Auto reset controls protect unit’s electrical circuitry and helps ensure trouble free performance. Built in circuit breakers for extra safety.
  • Adaptable: Unit can be adapted to provide dependable heating in either downflow or upflow mode.
  • Versatile: Works with self-contained or split system air conditioners or heat pumps.
MODELIDENTIFICATION
  1. Product Type
    E – Electric Furnace

  2. Generation
    3 – Third Series

  3. Product Identifier
    EB – A/C Blower Equipped Relay

  4. Electrical Code
    H – 240-1-60

  5. Primary Capacity
    010 – 10 kw    012 – 12 kw
    015 – 15 kw    017 – 17 kw
    020 – 20 kw    023 – 23 kw

Furnace Parts Identification
  1. Indoor Coil (optional)
  2. Coil Air Filters (used with indoor coil)
  3. Furnace Air Filter ( NOT used with coil air filters)
  4. Blower
  5. Circuit Breakers
  6. Data Label
  7. Control Panel Cover (left)
  8. Control Panel Cover (right)
Optional Accessories

Upflow Coil Cabinet

  1. Cabinet Insulation

Upflow Stand

UNIT SPECIFICATIONS

Electric Furnace Models|

E3EB

---|---

010H

| 012H| 015H| 017H| 020H| 023H|

023H 5-Ton

Rated Heating Output, Btuh (see note 1)|

35,000

| 41,000| 53,000| 57,000| 70,000| 75,000|

75,000

Watts (Total kw, Heating Elements and Blower)| 10.4| 12.0| 15.4| 16.6| 20.4| 22.0|

22.0

Supply Voltage|

240 Volts/60Hz/1-Phase

Heating Elements, No.(Total kw)|

2 (10.0)

| 2 (11.6) | 3 (15.0) | 3 (16.2)| 4 (20.0) | 4 (21.6)|

4 (21.6)

Blower Wheel Size|

10.5″ Dia, 8″ Wide

|

11” Dia., 8” W

Motor Speed, H.P. Rating, Amps|

4 Speed, 1/3 HP, 2.9

|

4 Spd, 3/4HP 3.8 Amps

Test ESP, in. w.c. Max|

0.3

Optional Cooling Available with factory installed blower|

2.0 – 4.0 Ton

|

2.0 – 5.0 Ton

Optional Heat Pump Available with factory installed blower |

2.0 – 4.0 Ton

Air Filter (Standard)|

16” x 20” x 1” (nominal)

Furnace Dimensions|

Width-20” (508mm), Height-29” (737mm) (see note 2), Depth-24 1/2” (623mm)

  1. Heating output rated at listed voltage. For outputs at voltages other than 240V, multiply Btuh rating by the following factors: x 0.92 (230V), x 0.84 (220V), x 0.75 (208V)
  2. Height is 56″ with return air grille installed, 58″ with coil cabinet and 72″ with coil cabinet and upflow stand.
ELECTRICALSPECIFICATIONS

*Model Number E3E()**

| Supply Circuit| Total Amperes| Maximum Over-current Rating| Minimum Circuit Ampacity
---|---|---|---|---

-010H

|

Single

| 44.6| 60| 56
-012H| Single| 51.2| 70|

64

Dual “A”

| 27.1| 40| 34
Dual “B”| 24.2| 30|

30

-015H

|

Single

| 65.4| 90| 82
Dual “A” | 44.6| 60|

56

Dual “B”

| 20.8| 30| 26

-017H

| Single| 70.4| 90|

88

Dual “A”

| 47.9| 60| 60
Dual “B”| 22.5| 30|

28

-020H

|

Single

| 86.2| 125| 108
Dual “A” | 44.6| 60|

56

Dual “B”

| 41.7| 60| 52

-023H

| Single| 93.8| 125|

117

Dual “A”

| 45.5| 60| 57
Dual “B”| 48.0| 60|

60

Replacement furnace for E2E(*)-015HB

Blower Performance

4-Ton Blower with Coil and Coil Filters, @ 0.3” ESP

Pin No.| Speed|

CFM

1

| Low| 880

2| Med.-Low|

1170

3

| Med.-High| 1310

4| High|

1460

5-Ton Blower, with Coil and Coil Filters, @ 0.3” ESP

Pin No.

| Speed| CFM

1 | Low|

990

2

| Med.-Low| 1320

3| Med.-High|

1620

4

| High|

1790

Anticipator Settings

Furnace Model

|

Thermostat Anticipator Setting

---|---

010, 012

| 0.2
015, 017, 020, 023 |

0.4

Clearances
ALL MODELS CLOSET ALCOVE
Front ‡ 

6”

|

18”

Back|

0”

|

0”

Sides|

0Ӡ

|

0Ӡ

Top and Sides of Duct|

0”

|

0”

Bottom of Duct|

0”

|

0”

‡ Service Clearance
† For upflow application using upflow stand, 1″ minimum per side

AIRFLOW DATA

E3EB (010, 012, 015, 017, 020, 023) H


Coil

|

High

| Med High| Med Low| Low
4-ton | No Coil | 3.5 ton| No Coil| 3-ton| No Coil| 2.5-ton|

None

Static (ESP) in W.C.

|

0.1

| 1559| 1503| 1389| 1362| 1227| 1203| 923| 885
0.2| 1506| 1458| 1352| 1330| 1208| 1174| 906|

863

0.3

| 1460| 1414| 1310| 1291| 1170| 1146| 880| 831
0.4| 1401| 1352| 1260| 1241| 1136| 1103| 845|

798

0.5

| 1333| 1282| 1198| 1179| 1086| 1055| 805| 758
0.6| 1251| 1208| 1133| 1113| 1027| 996| 757|

707

E3EB 023H-5 TON and 5 ton accessory blower


Coil

| High| Med High| Med Low|

Low

5-ton

| No Coil | 5-ton | No Coil | 5-ton | No Coil | 5-ton |

No Coil

Static (ESP) in W.C.

|

0.1

| 1911| 1886| 1709| 1679| 1394| 1373| 1054| 1032
0.2| 1860| 1821| 1663| 1630| 1359| 1333| 1027|

1004

0.3

| 1790| 1768| 1620| 1585| 1320| 1296| 880| 970
0.4| 1741| 1700| 1563| 1526| 1279| 1252| 952|

928

0.5

| 1671| 1643| 1511| 1473| 1229| 1201| 912| 884
0.6| 1613| 1584| 1444| 1400| 1182| 1147| 864|

824

ACCESSORIES

Description

|

Part Number

---|---
Blower, 2-4 Ton|

902993

Blower, 5 Ton|

902985

Heating Thermostat Intertherm (12 Pac)|

903188 (903182)

Heating Thermostat Miller (12 Pac)|

903189 (903183)

Thermostat Sub-Base|

914146

Heating/Cooling Thermostat CM65 Intertherm/Miller (12 Pac)|

903992 (903993)

Heating/Cooling Thermostat GE Intertherm (12 Pac)|

903192 (903186)

Heating/Cooling Thermostat GE Miller (12 Pac)|

903193 (903187)

Automatic Damper for AC or HP Package Unit |

901083

“VEE” Box Adapters (10”) – 5 / carton|

901985

Duct Connector 10” Dia. x 6” Long – 6 / carton |

902926

“VEE” Box Adapters (12”) – 5 / carton|

902149

Single Wide Fitting Kit (12”) |

911468A

Double Wide Fitting Kit (12”)|

911469A

Single Wide Fitting Kit (14”)|

914957

Double Wide Fitting Kit (14”)|

914956

Y-Fitting (12”)|

911470

Y-Fitting (14”)|

917195

Fan Delay Kit (TDR)|

911758

Top Grille/Frame|

902989

Top Grille/Frame (4 pack)|

903000

Wall Mount Top Grille (10 pack)|

902988

Coil Cabinet Upflow|

902976

Coil Cabinet Downflow (Front return)|

903891

Upflow Stand|

904620

Coil Cabinet, Downflow (Front and top return)|

904067

ACCESSORYKITS

Vent Kits|

Part Number

---|---
Soffit Air Inlet (for VentilAire III only)|

917201A

VentilAire III – Sloped 3/12|

914098

VentilAire IV – Sloped 3/12|

914229

Plenum Connectors|

Part Number

---|---
11.25 x 13.50 x 0.88 12 / carton|

901987A

11.25 x 13.50 x 2.00 12 / carton|

901988A

11.25 x 13.50 x 4.25 6 / carton|

901989A

11.25 x 13.50 x 6.25 6 / carton|

901990A

11.25 x 13.50 x 8.25 4 / carton|

901991A

11.25 x 13.50 x 10.25 3 / carton|

901992A

11.25 x 13.50 x 12.25 3 / carton|

901993A

11.25 x 13.50 x 6.25 24 / carton|

902681A

GENERAL TERMS OF LIMITED WARRANTY

Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.

For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (1 /2015)

936B-1114 (Replaces 936B-0214) www.intertherm.net

Trademark Intertherm® used under license.© Nortek Global HVAC, LLC. All Rights Reserved.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Intertherm User Manuals

Related Manuals