Technical Specifications

  • Product Name: G7S (A and K Series) Gas Furnaces
  • Type: Single Stage Upflow/Horizontal and Downflow
  • Induced Draft
  • 80+ AFUE
  • Input: 45,000 – 126,000 Btuh
  • Installation: Free standing in a utility room, basement, or enclosed in an alcove or closet
  • Design certified by CSA for application in Canada and theUnited States

Features and Benefits

  • Rounded corner jacket provides a pleasing appliance appearance
  • Approved and certified by the SCAQM and the SJVAPC Districts in the state of California
  • Approved for shipment into and sales in both districts
  • Not eligible for the Clean Air Furnace Rebate Program inCalifornia

Gas Furnace Components

  1. Blower Assembly
  2. Blower Door Switch
  3. Burner Assembly
  4. Control Board
  5. Flame Sensor
  6. Gas Manifold (Upflow/Horizontal Gas Furnace)
  7. Gas Valve
  8. Igniter
  9. Inducer
  10. Insulated Combustion Tube (Downflow Models)
  11. Low Voltage Transformer
  12. Main Air Limit Switch
  13. Pressure Switch
  14. Roll-Out Switch(s)

Dimensions

TOP VIEW C

  • Dimension A: 12 inches
  • Dimension B: 15 inches
  • Dimension C: 21 inches
  • Dimension D: 14 inches

FLANGES

B Accepts 4 Type B Vent Pipe

LEFT SIDE

Dimension A: 23 15/16 inches

FRONT VIEW

  • G7SA Single Stage Upflow/Horizontal Series
  • Dimension A: 23 1/2 inches

BOTTOM VIEW D

  • Front Brace
  • Bottom Panel
  • Dimension A: 22 1/4 inches
  • Dimension B: 25 inches

RIGHT SIDE

  • Dimension A: 28 inches
  • Dimension B: 29 1/2 inches
  • Dimension C: 22 1/2 inches
  • Dimension D: 22 3/4 inches

Model Identification Code

Gas Furnace Design Series:

  • S = Single Stage
  • T = Two Stage
  • M = Modulating

Cabinet Width:

  • A = 14.25 inches
  • B = 17.50 inches
  • C = 21.00 inches
  • D = 24.50 inches

Cooling Airflow:

  • 23 = 2-3 Tons
  • 24 = 2-4 Tons
  • 35 = 3-5 Tons
  • 45 = 4-5 Tons

Motor Technology:

  • V = VSHE
  • E = FSHE
  • T = 5 Tap ECM

NOx:

  • C/D = 40 Ng/J or less NOx
  • U = 14 Ng/J or less NOx

Specifications

G7SA Model Numbers:

  • -045-T23A1
  • -054-T23A1
  • -072-T24B1
  • -072-T35C1
  • -090-T24B1
  • -090-T35C1
  • -108-T35C1
  • -126-T45D1

Input – Btuh (a):

  • 45,000
  • 52,000
  • 70,000
  • 75,000
  • 90,000
  • 85,000
  • 108,000
  • 122,000

Heating Capacity – Btuh:

  • 36,000
  • 42,000
  • 56,000
  • 60,000
  • 72,000
  • 68,000
  • 86,000

Product Usage Instructions

Installation

The gas furnace can be installed free standing in a utilityroom, basement, or enclosed in an alcove or closet.

California Installation
This furnace series is approved and certified by the SCAQM and the SJVAPC Districts in the state of California under each Districts’ Mitigation Fee Plan for shipment into and sales in both districts. However, for installations in the SCAQMD (South Coast Air Quality Management District) only, this furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J), and thus is subject to a mitigation fee of up to $450. Additionally, thisfurnace is not eligible for the Clean Air Furnace Rebate Program.

Frequently Asked Questions (FAQ)

Q: Can the gas furnace be installed in a utility room?
A: Yes, the gas furnace can be installed free standing in a utility room.

Q: Is the gas furnace certified for use in Canada and the United States?
A: Yes, the gas furnace is design certified by CSA for application in Canada and the United States.

Q: Is the gas furnace eligible for the Clean Air Furnace Rebate Program in California?
A: No, this furnace is not eligible for the Clean Air Furnace Rebate Program.

Q: Does the gas furnace meet the SCAQMD Rule 1111 NOx emission limit in California?
A: No, this furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J) in California.

Q: What is the mitigation fee for installing this furnace in the SCAQMD?
A: The mitigation fee for installing this furnace in the SCAQMD can be up to $450.

TECHNICAL SPECIFICATIONS

G7S (A and K Series)
Single Stage Upflow/Horizontal and
Downflow Gas Furnaces
Induced Draft – 80+ AFUE
Input 45,000 – 126,000 Btuh
The gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.

This furnace series is approved and certified by the SCAQM and the SJVAPC Districts in the state of California under each Districts’ Mitigation Fee Plan for shipment into and sales in both districts.
For California installations in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J), and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.

FEATURES and BENEFITS

  • 100% fired and tested: All units and each component are tested on the manufacturing line.
  • Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
  • 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
  • 30 second post purge: Increases life of heat exchanger.
  • Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology.
  • Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  • High static blowers: All models equipped with high static blowers.
  • 60 second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a Nortek Global HVAC coil.
  • Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
  • High efficiency blower kits: Maximize efficiencies and provide better temperature control, humidity control and air distribution.
  • Multi-speed direct drive blower: Energy-efficient, brushless DC (ECM). Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra easy motor speed selection.
  • LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
  • Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
  • Integrated control board: Incorporates connections for electronic air cleaner and humidifier. Ergonomically located for ease of service.
  • Two piece door design: Enhances furnace appearance and uses captured screws to prevent loosing door screws.
  • Blower Compartment: Insulated for ultra quiet operation.
  • Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.

GAS FURNACE COMPONENTS

  1. Blower Assembly
  2. Blower Door Switch
  3. Burner Assembly
  4. Control Board
  5. Flame Sensor
  6. Gas Manifold
  7. Gas Valve
  8. Igniter
  9. Inducer
  10. Insulated Combustion Tube (Downflow Models)
  11. Low Voltage Transformer
  12. Main Air Limit Switch
  13. Pressure Switch
  14. Roll-Out Switch(s)

DIMENSIONS

*SA Model

#’s

| Dimension “A”| Dimension “B”| Dimension “C”| Dimension “D”
---|---|---|---|---
045-23A| 14 1/4| 10 3/4| 12 5/8| 12 7/8
054-23A
072-24B| 17 1/2| 11 3/4| 15 7/8| 16 1/8
090-24B
072-35C| ****

21

| ****

14

| 19 3/8| 19 7/8
090-35C
108-35C
126-45D| 24 1/2| 15 1/4| 22 7/8| 23 1/8

BROAN-G7S-Single-Stage-Upflow-Horizontal-and-Downflow-Gas-
Furnaces-3

G7SA Single Stage Upflow/Horizontal Series

*SK Model

#’s

| Dimension “A”| Dimension “B”| Dimension “C”| Dimension “D”
---|---|---|---|---
054-23A| 14 1/4| 10 3/4| 12 5/8| 12 7/8
072-24B| 17 1/2| 11 3/4| 15 7/8| 16 1/8
090-24B
108-35C| 21| 14| 19 3/8| 19 5/8
126-45D| 24 1/2| 15 1/4| 22 7/8| 23 1/8

BROAN-G7S-Single-Stage-Upflow-Horizontal-and-Downflow-Gas-
Furnaces-4

G7SK Single Stage Downflow Series

MODEL IDENTIFICATION CODE

BROAN-G7S-Single-Stage-Upflow-Horizontal-and-Downflow-Gas-
Furnaces-5

SPECIFICATIONS

G7SA MODEL NUMBERS| -045-T23A1| -054-T23A1| -072-T24B1| -072-T35C1| -090-T24B1| -090-T35C1| -108-T35C1| -126-T45D1
---|---|---|---|---|---|---|---|---
Input – Btuh (a)| 45,000| 52,000| 70,000| 75,000| 90,000| 85000| 108000| 122000
Heating Capacity – Btuh| 36,000| 42,000| 56,000| 60,000| 72,000| 68000| 86000| 98000
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0| 80| 80| 80
Motor H.P. – Speed – Type| 1/2 – 5 – ECM| 1/2 – 5 – ECM| 3/4 – 5 – ECM| 3/4 – 5 – ECM| 3/4 – 5 – ECM| 3/4-5-ECM| 1/2-5-ECM| 1/2-5-ECM
Motor FLA| 6.4| 6.4| 8.8| 8.8| 8.8| 8.8| 11.5| 11.5
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 30-60| 30-60| 35-65| 35-65| 35-65| 35-65| 40-70
Shipping Weights| 95 lbs| 95 lbs| 110 lbs| 115 lbs| 115 lbs| 134 lbs| 136 lbs| 147 lbs
G7SK MODEL NUMBERS| -054C-T23A1| -072-T24B1| -090-T24B1
---|---|---|---
Input – Btuh (a)| 54,000| 72,000| 90,000
Heating Capacity – Btuh| 43,000| 58,000| 72,000
AFUE| 80.0| 80.0| 80.0
Motor H.P. – Speed – Type| 1/2 – 5 – ECM| 3/4 – 5 – ECM| 3/4 – 5 – ECM
Motor FLA| 6.4| 8.8| 8.8
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 35-65| 35-65
Shipping Weights| 102 lbs| 110 lb| 115 lb

ACCESSORIES

G7S(A,K) KITS

Description| SKU
“A” Cabinet variable speed, high efficiency, VSHE| 904876
“B” Cabinet variable speed, high efficiency, VSHE| 904877
“C” Cabinet variable speed, high efficiency, VSHE| 904878
“D” Cabinet variable speed, high efficiency, VSHE| 904879
“A” Cabinet downflow sub base kit| 902974
“B”, “C”, “D” Cabinet downflow sub base kit| 904911
U.S. LP Conversion kit (0 to 10,000 ft.) and High Altitude LP| 905028
Canada LP Conversion kit (0 to 4,500 ft.) and High Altitude LP| 905029
Side return filter kit| 541036
Furnace Twinning Kit| 1010035

GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (02/2020)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals