BROAN G7S Single Stage Upflow/Horizontal and Downflow Gas Furnaces Owner’s Manual
- June 15, 2024
- Broan
Table of Contents
- BROAN G7S Single Stage Upflow/Horizontal and Downflow Gas Furnaces
- Product Information
- Product Usage Instructions
- TECHNICAL SPECIFICATIONS
- FEATURES and BENEFITS
- GAS FURNACE COMPONENTS
- DIMENSIONS
- MODEL IDENTIFICATION CODE
- SPECIFICATIONS
- ACCESSORIES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BROAN G7S Single Stage Upflow/Horizontal and Downflow Gas Furnaces
Product Information
Technical Specifications
- Product Name: G7S (A and K Series) Gas Furnaces
- Type: Single Stage Upflow/Horizontal and Downflow
- Induced Draft
- 80+ AFUE
- Input: 45,000 – 126,000 Btuh
- Installation: Free standing in a utility room, basement, or enclosed in an alcove or closet
- Design certified by CSA for application in Canada and theUnited States
Features and Benefits
- Rounded corner jacket provides a pleasing appliance appearance
- Approved and certified by the SCAQM and the SJVAPC Districts in the state of California
- Approved for shipment into and sales in both districts
- Not eligible for the Clean Air Furnace Rebate Program inCalifornia
Gas Furnace Components
- Blower Assembly
- Blower Door Switch
- Burner Assembly
- Control Board
- Flame Sensor
- Gas Manifold (Upflow/Horizontal Gas Furnace)
- Gas Valve
- Igniter
- Inducer
- Insulated Combustion Tube (Downflow Models)
- Low Voltage Transformer
- Main Air Limit Switch
- Pressure Switch
- Roll-Out Switch(s)
Dimensions
TOP VIEW C
- Dimension A: 12 inches
- Dimension B: 15 inches
- Dimension C: 21 inches
- Dimension D: 14 inches
FLANGES
B Accepts 4 Type B Vent Pipe
LEFT SIDE
Dimension A: 23 15/16 inches
FRONT VIEW
- G7SA Single Stage Upflow/Horizontal Series
- Dimension A: 23 1/2 inches
BOTTOM VIEW D
- Front Brace
- Bottom Panel
- Dimension A: 22 1/4 inches
- Dimension B: 25 inches
RIGHT SIDE
- Dimension A: 28 inches
- Dimension B: 29 1/2 inches
- Dimension C: 22 1/2 inches
- Dimension D: 22 3/4 inches
Model Identification Code
Gas Furnace Design Series:
- S = Single Stage
- T = Two Stage
- M = Modulating
Cabinet Width:
- A = 14.25 inches
- B = 17.50 inches
- C = 21.00 inches
- D = 24.50 inches
Cooling Airflow:
- 23 = 2-3 Tons
- 24 = 2-4 Tons
- 35 = 3-5 Tons
- 45 = 4-5 Tons
Motor Technology:
- V = VSHE
- E = FSHE
- T = 5 Tap ECM
NOx:
- C/D = 40 Ng/J or less NOx
- U = 14 Ng/J or less NOx
Specifications
G7SA Model Numbers:
- -045-T23A1
- -054-T23A1
- -072-T24B1
- -072-T35C1
- -090-T24B1
- -090-T35C1
- -108-T35C1
- -126-T45D1
Input – Btuh (a):
- 45,000
- 52,000
- 70,000
- 75,000
- 90,000
- 85,000
- 108,000
- 122,000
Heating Capacity – Btuh:
- 36,000
- 42,000
- 56,000
- 60,000
- 72,000
- 68,000
- 86,000
Product Usage Instructions
Installation
The gas furnace can be installed free standing in a utilityroom, basement, or enclosed in an alcove or closet.
California Installation
This furnace series is approved and certified by the SCAQM and the SJVAPC
Districts in the state of California under each Districts’ Mitigation Fee Plan
for shipment into and sales in both districts. However, for installations in
the SCAQMD (South Coast Air Quality Management District) only, this furnace
does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J), and thus is
subject to a mitigation fee of up to $450. Additionally, thisfurnace is not
eligible for the Clean Air Furnace Rebate Program.
Frequently Asked Questions (FAQ)
Q: Can the gas furnace be installed in a utility room?
A: Yes, the gas furnace can be installed free standing in a utility room.
Q: Is the gas furnace certified for use in Canada and the United States?
A: Yes, the gas furnace is design certified by CSA for application in
Canada and the United States.
Q: Is the gas furnace eligible for the Clean Air Furnace Rebate Program in
California?
A: No, this furnace is not eligible for the Clean Air Furnace Rebate
Program.
Q: Does the gas furnace meet the SCAQMD Rule 1111 NOx emission limit in
California?
A: No, this furnace does not meet the SCAQMD Rule 1111 NOx emission limit
(14 ng/J) in California.
Q: What is the mitigation fee for installing this furnace in the SCAQMD?
A: The mitigation fee for installing this furnace in the SCAQMD can be up
to $450.
TECHNICAL SPECIFICATIONS
G7S (A and K Series)
Single Stage Upflow/Horizontal and
Downflow Gas Furnaces
Induced Draft – 80+ AFUE
Input 45,000 – 126,000 Btuh
The gas furnace may be installed free standing in a utility room, basement, or
enclosed in an alcove or closet. The rounded corner jacket provides a pleasing
“appliance appearance.” Design certified by CSA for application in Canada and
the United States.
This furnace series is approved and certified by the SCAQM and the SJVAPC
Districts in the state of California under each Districts’ Mitigation Fee Plan
for shipment into and sales in both districts.
For California installations in SCAQMD only: This furnace does not meet the
SCAQMD Rule 1111 NOx emission limit (14 ng/J), and thus is subject to a
mitigation fee of up to $450. This furnace is not eligible for the Clean Air
Furnace Rebate Program:
www.CleanAirFurnaceRebate.com.
FEATURES and BENEFITS
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
- Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
- Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
- 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
- 30 second post purge: Increases life of heat exchanger.
- Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology.
- Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
- High static blowers: All models equipped with high static blowers.
- 60 second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a Nortek Global HVAC coil.
- Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
- High efficiency blower kits: Maximize efficiencies and provide better temperature control, humidity control and air distribution.
- Multi-speed direct drive blower: Energy-efficient, brushless DC (ECM). Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra easy motor speed selection.
- LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
- Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
- Integrated control board: Incorporates connections for electronic air cleaner and humidifier. Ergonomically located for ease of service.
- Two piece door design: Enhances furnace appearance and uses captured screws to prevent loosing door screws.
- Blower Compartment: Insulated for ultra quiet operation.
- Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.
GAS FURNACE COMPONENTS
- Blower Assembly
- Blower Door Switch
- Burner Assembly
- Control Board
- Flame Sensor
- Gas Manifold
- Gas Valve
- Igniter
- Inducer
- Insulated Combustion Tube (Downflow Models)
- Low Voltage Transformer
- Main Air Limit Switch
- Pressure Switch
- Roll-Out Switch(s)
DIMENSIONS
*SA Model
#’s
| Dimension “A”| Dimension “B”| Dimension “C”|
Dimension “D”
---|---|---|---|---
045-23A| 14 1/4| 10 3/4| 12 5/8| 12 7/8
054-23A
072-24B| 17 1/2| 11 3/4| 15 7/8| 16 1/8
090-24B
072-35C| ****
21
| ****
14
| 19 3/8| 19 7/8
090-35C
108-35C
126-45D| 24 1/2| 15 1/4| 22 7/8| 23 1/8
G7SA Single Stage Upflow/Horizontal Series
*SK Model
#’s
| Dimension “A”| Dimension “B”| Dimension “C”|
Dimension “D”
---|---|---|---|---
054-23A| 14 1/4| 10 3/4| 12 5/8| 12 7/8
072-24B| 17 1/2| 11 3/4| 15 7/8| 16 1/8
090-24B
108-35C| 21| 14| 19 3/8| 19 5/8
126-45D| 24 1/2| 15 1/4| 22 7/8| 23 1/8
G7SK Single Stage Downflow Series
MODEL IDENTIFICATION CODE
SPECIFICATIONS
G7SA MODEL NUMBERS| -045-T23A1| -054-T23A1| -072-T24B1| -072-T35C1|
-090-T24B1| -090-T35C1| -108-T35C1| -126-T45D1
---|---|---|---|---|---|---|---|---
Input – Btuh (a)| 45,000| 52,000| 70,000| 75,000| 90,000| 85000| 108000|
122000
Heating Capacity – Btuh| 36,000| 42,000| 56,000| 60,000| 72,000| 68000| 86000|
98000
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0| 80| 80| 80
Motor H.P. – Speed – Type| 1/2 – 5 – ECM| 1/2 – 5 – ECM| 3/4 – 5 – ECM| 3/4 –
5 – ECM| 3/4 – 5 – ECM| 3/4-5-ECM| 1/2-5-ECM| 1/2-5-ECM
Motor FLA| 6.4| 6.4| 8.8| 8.8| 8.8| 8.8| 11.5| 11.5
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 30-60| 30-60| 35-65| 35-65| 35-65| 35-65|
40-70
Shipping Weights| 95 lbs| 95 lbs| 110 lbs| 115 lbs| 115 lbs| 134 lbs| 136 lbs|
147 lbs
G7SK MODEL NUMBERS| -054C-T23A1| -072-T24B1| -090-T24B1
---|---|---|---
Input – Btuh (a)| 54,000| 72,000| 90,000
Heating Capacity – Btuh| 43,000| 58,000| 72,000
AFUE| 80.0| 80.0| 80.0
Motor H.P. – Speed – Type| 1/2 – 5 – ECM| 3/4 – 5 – ECM| 3/4 – 5 – ECM
Motor FLA| 6.4| 8.8| 8.8
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 35-65| 35-65
Shipping Weights| 102 lbs| 110 lb| 115 lb
ACCESSORIES
G7S(A,K) KITS
Description| SKU
“A” Cabinet variable speed, high efficiency, VSHE| 904876
“B” Cabinet variable speed, high efficiency, VSHE| 904877
“C” Cabinet variable speed, high efficiency, VSHE| 904878
“D” Cabinet variable speed, high efficiency, VSHE| 904879
“A” Cabinet downflow sub base kit| 902974
“B”, “C”, “D” Cabinet downflow sub base kit| 904911
U.S. LP Conversion kit (0 to 10,000 ft.) and High Altitude LP| 905028
Canada LP Conversion kit (0 to 4,500 ft.) and High Altitude LP| 905029
Side return filter kit| 541036
Furnace Twinning Kit| 1010035
GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this
product which fails in normal use and service within the terms and conditions
of the warranty.
For complete details of the Limited Warranty, including applicable terms and
conditions, see your local installer or contact the Nortek Global HVAC, LLC
warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (02/2020)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>