BROAN KG7S (A and K Series) Hight Efficiency Upflow/Horizontal And Dounflow Gas Furnace Owner’s Manual

June 15, 2024
Broan

BROAN Logo TECHNICAL SPECIFICATIONS
KG7S (A and K Series)

KG7S (A and K Series) Hight Efficiency Upflow/Horizontal And Dounflow Gas

Furnace

High Efficiency Upflow/Horizontal and Downflow Gas Furnaces
Induced Draft – 80+ AFUE
Input 45,000 – 126,000 Btuh
The high efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in the United States and Canada. BROAN KG7S \(A and K Series\)
Hight Efficiency Upflow Horizontal And Dounflow Gas
Furnace

FEATURES and BENEFITS

  • 100% fired and tested: All units and each component are tested on the manufacturing line.
  • Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent
  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
  • 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
  • 30 second post purge: Increases life of heat
  • Hot surface ignitor: Innovative application of an appliance type ignitor with a 20 year history of Utilizes proven Smartlite® technology.
  • Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  • High static blowers: All models equipped with high static
  • 90 second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a Nortek Global HVAC coil.
  • Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
  • High efficiency blower kits: Maximize On select units, a SEER improvement of up to 1 point is realized.
  • Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra easy motor speed selection.
  • LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
  • Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
  • Integrated control board: Incorporates connections for electronic air cleaner and
  • Two piece door design: Enhances furnace appearance and uses captured screws to prevent loosing door
  • Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.

GAS FURNACE COMPONENTS

BROAN KG7S \(A and K Series\) Hight Efficiency Upflow Horizontal And
Dounflow Gas Furnace - Figure 1

DIMENSIONS

*SA Model #’s| Dimension “A”| Dimension “B”| Dimension “C”| Dimension “D”
---|---|---|---|---
045-23A| 14 1/4| 10 3/4| 12 5/8| 12 7/8
054-23A
072-24B| 17 1/2| 11 3/4| 15 7/8| 16 1/8
090-24B
072-35C| 21| 14| 19 3/8| 19 7/8
090-35C
108-35C
126-45D| 24 1/2| 15 1/4| 22 7/8| 23 1/8

BROAN KG7S \(A and K Series\) Hight Efficiency Upflow Horizontal And
Dounflow Gas Furnace - DIMENSIONS

*SK Model #’s| Dimension “A”| Dimension “B”| Dimension “C”| Dimension “D”
---|---|---|---|---
054-23A| 14 1/4| 10 3/4| 12 5/8| 12 7/8
072-24B| 17 1/2| 11 3/4| 15 7/8| 16 1/8
090-24B
108-35C| 21| 14| 19 3/8| 19 5/8
126-45D| 24 1/2| 15 1/4| 22 7/8| 23 1/8

BROAN KG7S \(A and K Series\) Hight Efficiency Upflow Horizontal And
Dounflow Gas Furnace - DIMENSIONS 2

BLOWER PERFORMANCE – KG7SA

AIRFLOW DATABROAN KG7S \(A and K Series\) Hight Efficiency Upflow
Horizontal And Dounflow Gas Furnace - AIRFLOW DATABROAN KG7S \(A and K
Series\) Hight Efficiency Upflow Horizontal And Dounflow Gas Furnace - AIRFLOW
DATA 2

NOTES:

  • Factory Set Cooling Speed
    ** Factory Set Heating Speed

    1. Two openings are required for airflows above 1,600 CFM if filter(s) is(are) adjacent to furnace
    2. Temperature rises in the table are approximate. Actual temperature rises may vary.
    3. Temperature rises shaded in gray are not recommended.

Table 3. Continued

BROAN KG7S \(A and K Series\) Hight Efficiency Upflow Horizontal And
Dounflow Gas Furnace - AIRFLOW DATA 3 NOTES:

  • Factory Set Cooling Speed
    ** Factory Set Heating Speed

    1. Temperature rises in the table are approximate. Actual temperature rises may vary.
    2. Temperature rises shaded gray are not recommended.

Table 4. Maximum Airflow & Temperature Rises (° F) – Downflow Furnaces

MODEL IDENTIFICATION CODE

BROAN KG7S \(A and K Series\) Hight Efficiency Upflow Horizontal And
Dounflow Gas Furnace - MODEL IDENTIFICATION CODE

SPECIFICATIONS

KG7SA MODEL NUMBERS| -045-23A| -054-23A| -072-24B| -090-24B| -072-35C| -090-35C| -108-35C| -126-45D
---|---|---|---|---|---|---|---|---
Input – Btuh (a)| 45,000| 54,000| 72,000| 90,000| 72,000| 90,000| 108,000| 126,000
Heating Capacity – Btuh| 36,000| 43,200| 57,600| 72,000| 57,600| 72,000| 86,400| 100,800
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0
Blower D x W| 10 x 6| 10 x 6| 11 x 8| 11 x 8| 10 x 10| 10 x 10| 11 x 10| 11 x 10
Motor H.P. – Speed – Type| 1/3 – 4 – PSC| 1/3 – 4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1.0 – 4 – PSC| 1.0 – 4 – PSC
Motor FLA| 4.80| 4.80| 8.20| 8.20| 7.50| 7.50| 13.75| 13.75
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 30-60| 35-65| 35-65| 35-65| 35-65| 40-70| 40-70
Shipping Weights| 100lbs| 100lbs| 110lbs| 115lbs| 115lbs| 120lbs| 125lbs| 145lbs
KG7SK MODEL NUMBERS| -054-23A| -072-24B| -090-24B| -108-35C| -126-45D
---|---|---|---|---|---
Input – Btuh (a)| 54,000| 72,000| 90,000| 108,000| 126,000
Heating Capacity – Btuh| 43,200| 57,600| 72,000| 86,400| 100,800
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0
Blower D x W| 10 x 6| 11 x 8| 11 x 8| 11 x 10| 11 x 10
Motor H.P. – Speed – Type| 1/3 – 4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1.0 – 4 – PSC| 1.0 – 4 -PSC
Motor FLA| 4.80| 8.20| 8.20| 13.75| 13.75
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 35-65| 35-65| 40-70| 40-70
Shipping Weights| 100lbs| 110lbs| 115lbs| 125lbs| 145lbs

ACCESSORIES

KG7S (A, K) KITS


Description| SKU
“A” Cabinet fixed speed, high efficiency, FSHE| 904872
“B” Cabinet fixed speed, high efficiency, FSHE| 904873
“C” Cabinet fixed speed, high efficiency, FSHE| 904874
“D” Cabinet fixed speed, high efficiency, FSHE| 904875
“A” Cabinet variable speed, high efficiency, VSHE| 904876
“B” Cabinet variable speed, high efficiency, VSHE| 904877
“C” Cabinet variable speed, high efficiency, VSHE| 904878
“D” Cabinet variable speed, high efficiency, VSHE| 904879
“A” Cabinet downflow sub base kit| 902974
“B”, “C”, “D” Cabinet downflow sub base kit| 904911
U.S. LP Conversion kit (0 to 10,000 ft.)| 905028
Canada LP Conversion kit (0 to 4,500 ft.)| 905029
Bottom return filter 20 per box, “A” cabinet| 903088A
Bottom return filter 20 per box, “B” cabinet| 904916
Bottom return filter 20 per box, “C” cabinet| 904917
Bottom return filter 20 per box, “D” cabinet| 904918
Side return filter kit| 541036

BROAN KG7S \(A and K Series\) Hight Efficiency Upflow Horizontal And
Dounflow Gas Furnace - Symbol 1 GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (09/2016)