NuTone FG7S High-Efficiency Single-Stage Condensing
Product Information
Technical Specifications
- Model: FG7S (D and M Series)
- Type: High Efficiency, Single Stage Condensing Gas Furnace
- Installation: Upflow/Horizontal and Downflow
- AFUE: 95.0
- Input Range: 38,000 – 120,000 Btuh
- Certification: Design certified by CSA for application in Canada and the United States
Warranty
The product comes with a warranty. Please refer to the warranty documentation for detailed information.
Features and Benefits
- High efficiency
- Single-stage condensing technology
- Multiple installation options (upflow/horizontal and downflow)
- Flame sensor for reliable ignition
- Finish flange for a pleasing appearance
- Roll-out switch for safety
- Main air limit switch for temperature control
- Inducer limit switch for proper airflow
- Pressure switch for inducer operation
- Inducer assembly for efficient combustion
- Blower door switch for safety
- Burner assembly for efficient heat transfer
- Igniter for ignition
- Gas valve for fuel control
- Furnace control board for system operation
- Transformer for electrical power supply
- Blower assembly for air circulation
- Pressure switch for condensate management
- Gas manifold for fuel distribution
Dimensions
SD Upflow / Horizontal Furnaces
Model # | Dim. – A – | Dim. – B – | Dim. – C – |
---|---|---|---|
038D-24B | 17 1/2″ | 15 7/8″ | 16 1/8″ |
054D-24B | 21″ | 19 3/8″ | 19 5/8″ |
072D-35C | 24 1/2″ | 22 7/8″ | 23 1/8″ |
090D-35C | 28″ | 26 1/4″ | 25 1/2″ |
108D-45D | 34 1/2″ | 17 1/4″ | 17 7/8″ |
120D-45D | 34 1/2″ | 17 1/4″ | 17 7/8″ |
SM Downflow Furnaces
Model # | Dim. – A – | Dim. – B – | Dim. – C – |
---|---|---|---|
054D-24B | 17 1/2″ | 15 7/8″ | 16 1/8″ |
072D-35C | 21″ | 19 3/8″ | 19 5/8″ |
090D-35C | 24 1/2″ | 22 7/8″ | 23 1/8″ |
118D-45D | 28″ | 26 1/4″ | 25 1/2″ |
Blower Performance – FG7SD
Model Number & Heating Input (Btuh)| Motor Speed| External Static Pressure
(Inches Water Column)| CFM Rise
---|---|---|---
SD038D-24B BottomReturn (38,000)| HIGH*| 0.1| 1519
SD038D-24B SideReturn (38,000)| MED-H| 0.2| 1483
SD054D-24B BottomReturn (54,000)| MED-L LOW| 0.3| 1433
SD054D-24B SideReturn (54,000)| HIGH*| 0.4| 1397
SD072D-35C BottomReturn (54,000)| MED-H| 0.5| 1335
SD072D-35C SideReturn (54,000)| MED-L*| 0.6| 1272
SCD72D-35C Side+Bottom or 2Sides (72,000)| LOW| 0.7| 1214
SD090D-35C BottomReturn (90,000)| HIGH| 0.8| 1130
SD090D-35C SideReturn (90,000)| MED-H| | 1238
SCD90D-35C Side+Bottom or 2Sides (90,000)| MED-L| | 1216
Product Usage Instructions
Installation
The high-efficiency upflow gas furnace can be installed free-standing in a
utility room, or basement, or enclosed in an alcove or closet.
Upflow/horizontal units come ready for upflow or horizontal application.
The extended flush jacket provides a pleasing appliance appearance. Please
ensure that the installation is done by a qualified professional and follows
all local building codes and regulations.
Operation
To operate the gas furnace, follow these steps
- Ensure that the gas supply is connected and turned on.
- Set the thermostat to the desired temperature.
- The furnace control board will initiate the ignition sequence.
- The igniter will light the burner assembly.
- The blower assembly will circulate the heated air throughout the system.
- The main air limit switch and inducer limit switch will monitor and control the temperature and airflow.
- During operation, the pressure switches will ensure proper inducer and condensate operation.
Maintenance
Regular maintenance is important to ensure the efficient and safe operation of the gas furnace. Here are some maintenance tasks:
- Clean or replace the air filters regularly.
- Inspect and clean the burner assembly.
- Check and clean the flame sensor.
- Inspect and test the safety switches (roll-out switch, blower door switch, inducer limit switch).
- Check for any gas leaks.
- Inspect and clean the blower assembly.
- Check and clean the condensate drain system.
FAQ
Q: Can I install the gas furnace myself?
A: It is recommended to have the gas furnace installed by a qualified professional to ensure proper installation and compliance with local building codes and regulations.
TECHNICAL SPECIFICATIONS
FG7S (D and M Series) High Efficiency, Single Stage
- Condensing, Upflow/Horizontal, and Downflow Gas Furnace Models 95.0 AFUE 38,000 – 120,000 Btuh Input
- The high-efficiency upflow gas furnace may be installed free-standing in a utility room, or basement, or enclosed in an alcove or closet.
- Upflow/horizontal units come ready for upflow or horizontal application. The extended flush jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.
WARRANTY
- 10-year all-parts warranty.
- 10 Year Quality Pledge to replace the unit if the heat exchanger fails within the first 10 years of operation, to the original owner.
- Consumer product registration is required for 10 years All Parts Warranty and Quality Pledge within a limited time after the installation.
- See the current warranty document or visit our consumer website listed on the back of this document for warranty details.
- When registered, this product is upgraded to a limited lifetime heat exchanger warranty.
FEATURES and BENEFITS
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design assures the product will arrive to the homeowner dent-free.
- 30-second blower delay at start-up assures a warm duct temperature at furnace start-up. Adjustable blower-off settings (60, 90, 120 and 180 seconds).
- 30-second post-purge increases the life of the heat exchanger.
- Hot surface igniter: Innovative application of a silicon nitride type igniter. Utilizes proven Smartlite® technology.
- Color-coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
- Flexible category IV venting system: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum installation flexibility.
- High Static Blowers: All models are equipped with high static blowers.
- Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
- Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger ensure a long life.
- 60-second fixed cooling cycle blower-off delay (TDR) increases cooling performance when matched with a NORDYNE coil.
- High-efficiency blower kits maximize efficiencies. On select units, a SEER improvement of up to 1 point is realized.
- Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra-easy motor speed selection.
- LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
- Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy-to-recognize states without counting flashes.
- Incorporates integrated control board with connections for electronic air cleaner and humidifier.
- Two-piece door design enhances furnace appearance and uses captured screws to prevent losing door screws.
- Blower Compartment: Sealed door to reduce air leakage and insulated for ultra-quiet operation.
- Sealed Vestibule reduces burner and inducer sound levels.
GAS FURNACE COMPONENTS
DIMENSIONS
*SD Upflow / Horizontal Furnaces
Model #’s| Dim. -A-| Dim -B-| Dim -C-
038D-24B| 17 1/2| 15 7/8| 16 1/8
054D-24B
072D-35C| 21| ****
19 3/8
| 19 5/8
090D-35C
108D-45D| 24 1/2| 22 7/8| 23 1/8
120D-45D
NOTE: Dimensions are shown in inches.
BLOWER PERFORMANCE – FG7SD
*SD – UPFLOW / HORIZONTAL FURNACES|
---|---
Model Number &
Heating Input (Btuh)
| ****
Motor Speed
| External Static Pressure (Inches Water Column)|
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7|
0.8|
CFM| Rise| CFM| Rise| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise|
| HIGH *****| 1519| 21| 1483| 22| 1433| 22| 1397| 23| 1335| 24| 1272| 25|
1214| 26| 1130| 27|
SD038D-24B
Bottom Return (38,000)
| MED-H **
MED-L
| 1238
1094
| 28| 1216
1082
| 28| 1188
1052
| 28| 1164
1034
| 29| 1136
1021
| 30
34
| 1092
977
| 31
34
| 1043
928
| 32
36
| 973
865
| 34
37
|
31| 32| 32| 33|
| LOW| 841| 40| 817| 42| 801| 43| 786| 45| 750| 46| 720| 48| 683| 49| 639|
53|
| HIGH *****| 1664| 18| 1631| 21| 1596| 21| 1546| 22| 1489| 23| 1433| 24|
1366| 25| 1285| 26|
SD038D-24B
Side Return (38,000)
| MED-H
MED-L **
| 1272
1130
| 26
29
| 1255
1114
| 27| 1249
1100
| 27| 1217
1079
| 28| 1189
1048
| 29| 1145
1025
| 30
33
| 1096
987
| 31
35
| 1036
944
| 33
36
|
31| 31| 31| 33|
| LOW| 869| 39| 839| 42| 809| 42| 790| 44| 764| 45| 739| 47| 711| 48| 664|
52|
| HIGH *| 1519| 33| 1483| 34| 1433| 35| 1397| 36| 1335| 37| 1272| 39|
1214| 41| 1130| 44|
SD054D-24B| MED-H| 1238| 40| 1216| 41| 1188| 42| 1164| 43| 1136| 44| 1092| 46|
1043| 48| 973| 51|
Bottom Return (54,000)| MED-L **| 1094| 46| 1082| 46| 1052| 48| 1034| 48|
1021| 49| 977| 51| 928| 54| 865| 58|
| LOW| 841| 59| 817| 61| 801| 62| 786| 64| 750| 67| 720| 69| 683| 73| 639|
78|
| HIGH *| 1664| 30| 1631| 31| 1596| 31| 1546| 32| 1489| 34| 1433| 35|
1366| 37| 1285| 39|
SD054D-24B
Side Return (54,000)
| MED-H
MED-L **
| 1272
1130
| 39
44
| 1255
1114
| 40
45
| 1249
1100
| 40
45
| 1217
1079
| 41
46
| 1189
1048
| 42
48
| 1145
1025
| 44
49
| 1096
987
| 46
51
| 1036
944
| 48
53
|
| LOW| 869| 58| 839| 60| 809| 62| 790| 63| 764| 65| 739| 68| 711| 70| 664|
75|
| HIGH *****| 1933| 34| 1857| 36| 1780| 37| 1695| 39| 1599| 42| 1498| 45|
1396| 48| 1280| 52|
SD072D-35C
Bottom Return (54,000)
| MED-H **
MED-L
| 1872
1320
| 36
51
| 1804
1299
| 37
51
| 1731
1264
| 39
53
| 1639
1233
| 41
54
| 1551
1183
| 43
56
| 1458
1126
| 46
59
| 1353
1059
| 49
63
| 1237
963
| 54|
69|
| LOW| 1185| 56| 1170| 57| 1132| 59| 1102| 60| 1067| 62| 1015| 66| 947| 70|
856| 78|
| HIGH *****| 1916| 35| 1848| 36| 1773| 38| 1692| 39| 1613| 41| 1515| 44|
1426| 47| 1316| 51|
SD072D-35C
Side Return (54,000)
| MED-H **
MED-L
| 1815
1259
| 37
53
| 1771
1241
| 38
54
| 1711
1224
| 39
54
| 1641
1192
| 41
56
| 1553
1163
| 43
57
| 1468
1115
| 45
60
| 1373
1056
| 49
63
| 1270
982
| 52|
68|
| LOW| 1139| 59| 1120| 60| 1096| 61| 1075| 62| 1047| 64| 1014| 66| 959| 70|
884| 75|
SCD72D-35C
Side + Bottom or 2 Sides
(72,000)
| HIGH * MED-H ** MED-L| 1954
1869
1287
| 34| 1890
1805
1262
| 35
37
53
| 1824
1741
1231
| 37
38
54
| 1741
1685
1197
| 38
40
56
| 1656
1607
1166
| 40
41
57
| 1564
1516
1117
| 43
44
60
| 1470
1419
1061
| 45
47
63
| 1352
1308
966
| 49
51
|
36
52
|
69|
66| 70|
| LOW| 1147| 58| 1115| 60| 1097| 61| 1075| 62| 1047| 64| 1014| 959| 884| 75|
| HIGH *****| 2288| 36| 2236| 37| 2161| 39| 2092| 40| 2017| 41| 1934| 43|
1841| 45| 1748| 48|
SD090D-35C
Bottom Return (90,000)
| MED-H **
MED-L
| 2144
1874
| 39
44
| 2093
1845
| 40
45
| 2049
1806
| 41
46
| 1985
1766
| 42
47
| 1912
1717
| 44
49
| 1842
1661
| 45
50
| 1764
1582
| 47
53
| 1668
1503
| 50
55
|
| LOW| 1541| 54| 1516| 55| 1509| 55| 1486| 56| 1456| 57| 1402| 59| 1361| 61|
1294| 64|
| HIGH *****| 2273| 37| 2222| 38| 2164| 39| 2098| 40| 2025| 41| 1947| 43|
1864| 45| 1780| 47|
SD090D-35C
Side Return (90,000)
| MED-H **
MED-L
| 2084
1784
| 40
47
| 2039
1777
| 41
47
| 2007
1749
| 42
48
| 1955
1725
| 43
48
| 1895
1679
| 44
50
| 1832
1629
| 45
51
| 1750
1576
| 48
53
| 1665
1501
| 50
56
|
| LOW| 1482| 56| 1470| 57| 1444| 58| 1432| 58| 1405| 59| 1375| 61| 1339| 62|
1286| 65|
SCD90D-35C
Side + Bottom or 2 Sides
(90,000)
| HIGH * MED-H ** MED-L| 2328
2124
1825
| 36
39
46
| 2273
2108
1809
| 37
40
46
| 2224
2052
1781
| 37
41
47
| 2151
2018
1752
| 39
41
48
| 2082
1954
1706
| 40
43
49
| 2005
1884
1676
| 42
44
50
| 1920
1813
1615
| 43
46
52
| 1825
1725
1535
| 46
48
54
|
| LOW| 1509| 55| 1488| 56| 1468| 57| 1440| 58| 1422| 59| 1379| 60| 1351| 62|
1292| 64|
*SD – UPFLOW / HORIZONTAL FURNACES|
---|---
Model Number &
Heating Input (Btuh)
| ****
Motor Speed
| External Static Pressure (Inches Water Column)|
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7|
0.8|
CFM| Rise| CFM| Rise| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise|
SD108D-45D
Bottom Return (108,000)
| HIGH * MED-H ** MED-L
LOW
| 2276
2113
1819
1496
| 44
47
55
67
| 2228
2078
1789
1484
| 45
48
56
67
| 2173
2019
1757
1459
| 46
50
57
69
| 2108
1970
1706
1430
| 47
51
59
70
| 2035
1904
1666
1402
| 49
53
60
| 1961
1840
1610
1363
| 51
54
62
| 1876
1768
1551
1330
| 53
57
64
| 1778
1677
1486
1262
| 56
60
67
|
71| 73| 75| 79|
SD108D-45D
Side Return (108,000)
| HIGH * MED-H ** MED-L
LOW
| 2306
2135
1845
1543
| 43
47
54
65
| 2247
2103
1834
1521
| 45
50
57
69
| 2192
2050
1805
1502
| 46
51
58
70
| 2121
1995
1776
1477
| 47
53
59
| 2044
1935
1719
1452
| 49
54
61
| 1979
1858
1663
1412
| 51
57
63
| 1892
1778
1605
1368
| 53
59
66
| 1787
1690
1533
1314
| 56
62
69
|
71| 73| 75| 77| 80|
SD120D-45D
Bottom Return (120,000)
| HIGH * MED-H ** MED-L
LOW
| 2276
2113
1819
1496
| 49
53
61
| 2228
2078
1789
1484
| 50
53
62
| 2173
2019
1757
1459
| 51
55
63
| 2108
1970
1706
1430
| 53
56
65
| 2035
1904
1666
1402
| 55
58
67
| 1961
1840
1610
1363
| 57
60
69
| 1876
1768
1551
1330
| 59
63
| 1778
1677
1486
1262
| 62
66
|
72
84
| 75
88
|
74| 75| 76| 78| 79| 82|
SD120D-45D
Side Return (120,000)
| HIGH * MED-H ** MED-L
LOW
| 2306
2135
1845
1543
| 48
52
60
| 2247
2103
1834
1521
| 49
53
61
| 2192
2050
1805
1502
| 51
54
62
| 2121
1995
1776
1477
| 52
56
63
| 2044
1935
1719
1452
| 54
57
65
| 1979
1858
1663
1412
| 56
60
67
| 1892
1778
1605
1368
| 59
62
69
| 1787
1690
1533
1314
| 62
66
|
72
85
|
72| 73| 74| 75| 77| 79| 81|
BLOWER PERFORMANCE – FG7SM
*SM – DOWNFLOW FURNACES|
---|---
Model Number &
Heating Input (Btuh)
| ****
Motor Speed
| External Static Pressure (Inches Water Column)|
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7|
0.8|
CFM| Rise| CFM| Rise| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise|
SM054D-24B
Top Return (54,000)
| HIGH * MED-H MED-L **
LOW
| 1590
1228
1096
855
| 31
41
46
58
| 1563
1207
1079
825
| 32
41
46
| 1538
1193
1061
800
| 33
42
47
| 1513
1169
1038
777
| 33
43
48
| 1477
1157
1010
753
| 34
43
50
| 1430
1127
986
723
| 35
44
51
| 1370
1084
957
696
| 36
46
52
| 1312
1037
919
665
| 38
48
54
|
61| 63| 64| 66| 69| 72| 75|
SM072D-35C
Top Return (72,000)
| HIGH * MED-H ** MED-L
LOW
| 2235
2095
1871
1568
| 30
32
| 2176
2052
1838
1552
| 31
32
| 2121
2005
1797
1527
| 31
33
| 2067
1957
1761
1485
| 32
34
| 2010
1906
1716
1457
| 33| 1936
1852
1667
1418
| 34| 1864
1781
1602
1370
| 36
37
42
49
| 1783
1709
1536
1343
| 37
39
43
50
|
35
39
46
| 36
40
47
|
36
43
| 36
43
| 37
44
| 38
45
|
SM090D-35C
Top Return (90,000)
| HIGH * MED-H ** MED-L
LOW
| 2208
2065
1802
1490
| 38
40
46
56
| 2150
2015
1773
1482
| 39
41
47
56
| 2089
1970
1750
1464
| 40
42
48
57
| 2026
1910
1703
1436
| 41
44
49
58
| 1959
1866
1670
1407
| 43
45
50
59
| 1893
1805
1623
1380
| 44
46
51
60
| 1825
1737
1556
1329
| 46
48
54
63
| 1738
1668
1490
1271
| 48
50
56
|
66|
SM118D-45D
Top Return (118,000)
| HIGH * MED-H ** MED-L
LOW
| 2358
2176
1873
1544
| 46
50
58
| 2299
2135
1852
1528
| 48
51
59
| 2253
2102
1816
1514
| 48
52
60
| 2191
2046
1790
1499
| 50
53
61
| 2130
1985
1750
1462
| 51
55
62
| 2060
1932
1699
1441
| 53
57
64
| 1990
1862
1643
1429
| 55
59
66
| 1903
1777
1571
1386
| 57
61
70
|
71| 72| 72| 73| 75| 76| 76| 79|
NOTES:
- Factory Set Cooling Speed
- Factory Set Heating Speed
- Two openings are recommended for airflows above 1,600 CFM if filter(s) is(are) adjacent to the furnace
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Temperature rises shaded in gray are for reference only. These conditions are not recommended
VENTING
All models are approved for vertical nondirect (1 pipe) and direct (2 pipe) venting applications. See the Vent Table below for specified sizes and allowable lengths.
VENT TABLE
| SINGLE PIPE LENGTH (FT.)
with 1 long radius elbow*
| DIRECT VENT,
DUEL PIPE LENGTH (ft.) WITH
1 long radius elbow on each pipe*
---|---|---
OUTLET| OUTLET| INLET/OUTLET| INLET/OUTLET
MODELS| 2”| 3”| 2”| 3”
SD038| 50| 70| 50| 70
SD054| 70| 90| 70| 90
SD072| 50| 90| 50| 90
SD090| 60| 90| 60| 90
SD108| N/A| 90| N/A| 90
SD120| N/A| 90| N/A| 90
SM054| 70| 90| 70| 90
---|---|---|---|---
SM072| 50| 90| 50| 90
SM090| 60| 90| 60| 90
SM118| N/A| 90| N/A| 90
NOTE:
- Subtract 2.5 ft. for each additional 2″ elbow and 3.5 ft. for each additional 3″ elbow.
- Two 45-degree elbows are equivalent to one 90-degree elbow.
- One short-radius elbow is equivalent to two long-radius elbows.
- Do not include termination elbows in the calculation of vent length.
- This table applies for elevations from sea level to 2000 ft. For higher elevations decrease vent pipe lengths by 8% per 1000 ft. of altitude.
- Only the listed pipe materials are approved for use with FG7 Condensing Furnaces.
MODEL IDENTIFICATION CODE
118 = 118,000 for SM Models
SPECIFICATIONS
FG7SD MODEL NUMBERS:| -038D-24B| -054D-24B| -072D-35C|
-090D-35C| -108D-45D| -120D-45D
---|---|---|---|---|---|---
Input – Btuh (a)| 38,000| 54,000| 72,000| 90,000| 108,000| 120,000
Heating Capacity – Btuh| 36,100| 51,300| 68,400| 85,500| 102,600| 114,000
AFUE| 95.0| 95.0| 95.0| 95.0| 95.0| 95.0
Blower D x W| 10 x 8| 11 x 8| 10 x 10| 11 x 10| 11 x 10| 11 x 10
Motor H.P. – Speed – Type| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1 – 4
– PSC| 1 – 4 – PSC| 1 – 4 – PSC
Motor FLA| 8.6| 8.6| 8.0| 13.75| 13.75| 13.75
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 30-60| 35-65| 35-65| 40-70| 40-70
Shipping Weights| 100lbs| 120lbs| 130lbs| 135lbs| 155lbs| 155lbs
FG7SD MODEL NUMBERS:| -038D-24B| -054D-24B| -072D-35C|
-090D-35C| -108D-45D| -120D-45D
---|---|---|---|---|---|---
Input – Btuh (a)| 38,000| 54,000| 72,000| 90,000| 108,000| 120,000
Heating Capacity – Btuh| 36,100| 51,300| 68,400| 85,500| 102,600| 114,000
AFUE| 95.0| 95.0| 95.0| 95.0| 95.0| 95.0
Blower D x W| 10 x 8| 11 x 8| 10 x 10| 11 x 10| 11 x 10| 11 x 10
Motor H.P. – Speed – Type| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1 – 4
– PSC| 1 – 4 – PSC| 1 – 4 – PSC
Motor FLA| 8.6| 8.6| 8.0| 13.75| 13.75| 13.75
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 30-60| 35-65| 35-65| 40-70| 40-70
Shipping Weights| 100lbs| 120lbs| 130lbs| 135lbs| 155lbs| 155lbs
Note:
- All models are 115V, and 60 Hz. Gas Connections are 1/2″ N.P.T. AFUE = Annual Fuel Utilization Efficiency (a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.
ACCESSORIES
FG7S (D, M) KITS
Description| SKU
2″ Concentric vent kit| 904952
3″ Concentric vent kit| 904953
“B”, “C”, “D” Cabinet downflow sub base kit| 904911
2″ Side wall vent kit| 904617
3″ Side wall vent kit| 904347
U.S. LP Conversion kit (0 to 10,000 ft.)| 905028
Canada LP Conversion kit (0 to 4,500 ft.)| 905029
Bottom return filter 20 per box, “B” cabinet| 904916
Bottom return filter 20 per box, “C” cabinet| 904917
Bottom return filter 20 per box, “D” cabinet| 904918
Side return filter kit| 541036
Neutralizer kit| 902377
“A” Cabinet fixed speed, high efficiency, FSHE| 904872
“B” Cabinet fixed speed, high efficiency, FSHE| 904873
“C” Cabinet fixed speed, high efficiency, FSHE| 904874
“D” Cabinet fixed speed, high efficiency, FSHE| 904875
“A” Cabinet variable speed, high efficiency, VSHE| 904876
“B” Cabinet variable speed, high efficiency, VSHE| 904877
“C” Cabinet variable speed, high efficiency, VSHE| 904878
“D” Cabinet variable speed, high efficiency, VSHE| 904879
GENERAL TERMS OF LIMITED WARRANTY
- Nortek Global HVAC, LLC will furnish a replacement for any part of this product that fails in normal use and service within the terms and conditions of the warranty.
- For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
- Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
- Specifications and illustrations are subject to change without notice and without incurring ob ligations. Printed in U.S.A (10/2015)
- 749D-0512 (Replaces 749D-0212)
- www.nutonehvac.com
- NuTone® trademark used under license. © Nortek Global HVAC, LLC. All Rights Reserved.