Specifications
- Product: Manual retrofit toilet flushometer, 1.28 gpf K-13517-RF
- Dimensions:
- Height: 6-3/8″ (162 mm)
- Width: 2-3/4″ (70 mm)
- Depth: 3-1/2″ (89 mm)
- Length: 7-1/2″ (191 mm)
- Pressure/Fixture Supply Requirements:
- Fixture Pressure Max (static): 80 psi (551.6 kPa)
- Min Flowing Pressure: 25 psi (172.4 kPa)
- Min Flow Rate: 25 gpm (94.6 lpm)
Product Information
- This manual retrofit toilet flushometer features efficient water usage with a flow rate of 1.28 gallons per flush (gpf) to help conserve water.
- The product is constructed from durable materials to ensure longevity and reliability in operation.
- The flushometer incorporates advanced flushing technology for effective waste removal with minimal water consumption.
- Proper installation is crucial for optimal performance. Refer to the installation guide provided with the product for detailed instructions.
- The product must be correctly connected to the existing plumbing system following the recommended guidelines to ensure proper functionality.
- To maintain the product, it is recommended to use K-23723 Faucet cleaner as an accessory for cleaning and upkeep.
- The product complies with ADA, OBC, and CSA B651 regulations when installed according to their specific requirements.
- All product dimensions provided are nominal. Follow the specified pressure and flow requirements for optimal performance.
Features
- Fixture-mount design
- Retrofit models require a control stop and vacuum breaker
Material
- Brass
Technology
- Nonhold open piston technology for accurate activation
Installation
- Intended for toilet installations with 1-1/2″ spud coupling connection
Recommended Products/Accessories
- K-23723 Faucet cleaner
Codes/Standards
- ASME A112.18.1/CSA B125.1
- CSA B64
- CSA B125.3
- ASSE 1037/ASME A112.1037/CSA B125.37
- All applicable US Federal and State material regulations
- EPA WaterSense®
- ADA
- ICC/ANSI A117.1
- CSA B651
- OBC
- IAPMO Certification
KOHLER® One-Year Limited Warranty
- See the website for detailed warranty information.
Dimension
Technical Information
- All product dimensions are nominal.
Pressure/fixture Supply Requirements
- Fixture pressure max (static): 80 psi (551.6 kPa)
- Min flowing pressure: 25 psi (172.4 kPa)
- Min flow rate: 25 gpm (94.6 lpm)
Notes
- Install this product according to the installation guide.
- ADA, OBC, CSA B651 compliant when installed to the specific requirements of these regulations.
CONTACT
- 1-800-4KOHLER (1-800-456-4537)
- Kohler Co. reserves the right to make revisions without notice to product specifications.