Sofucor 6004 52 Inch Ceiling Fan Without Light Instruction Manual

June 15, 2024
Sofucor

Sofucor 6004 52 Inch Ceiling Fan Without Light Instruction Manual

SAFTY RULES

. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.
2. All wiring must be in accordance with the National Electrical Code and local electrical codes. Electrical installation should be performed by a qualified licensed electrician.
3. WARNING: To reduce the risk of electrical shock and fire, do not use this fan with any solid-state fan speed control device.
4. WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “Acceptable for Fan Support of 45kg (99.12 lbs.) Or Less and use mounting screws provided with the outlet box, Most outlet boxes commonly used for the support of light fixtures are not acceptable for fan support and may need to be replaced. Due to the complexity of the installation of this fan, a qualified licensed electrician is strongly recommended.
5. The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 45KGS. Use only UL Listed outlet boxes marked FOR FAN SUPPORT
6. The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor.
7. Avoid placing objects in the path of the blades.
B. To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.
9. Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth
will be suitable for most cleaning
10. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box
11. Electrical diagrams are for reference only.
12. The fan is suitable for indoor use only.

TOOLS REQUIRED

BEFORE INSTALLATION

Unpack your fan and check the contents. You should have followings:

  1. Mounting Bracket X 1
  2. Canopy X 1
  3.  Canopy Screws X 2
  4. Downrod (Short rod 12.5cm) X1 (Long pole25cm)X1
  5. Bolt X 1
  6.  Bolt X 1
  7. Pin Cover X 1
  8. DC MotorX 1
  9. Blade X 3
  10. Base Plate X 1
  11. Remote Receiver X 1
  12.  Remote Control X 1

Note: the remote receiver must match the same code control

| | |
---|---|---|---
Explosion screw| Balance sticker| Self-tapping screws| 1/4*25mm

INSTALL THE FAN

Tools Required: Phillips Screwdriver, Pair of Pliers, Straight slot screwdriver, Adjustable Wrench, Step Ladder and Wire Cutters.

INSTALL THE MOUNTING BRACKET

To prevent personal injury and damage, ensure that the hanging location allows the blade a clearance of 7.5 feet (2.3 metets) from the floor and 18 inches (45.72 centimeters) from any wall or obstruction.

For the concrete ceiling: Mark the location for the ceiling fan first, then drill two holes in the ceiling to aid in securing ceiling bracket with two expansion screws provided, and secure the mounting bracket to the building structure with two expansion screws provided, tighten the screws. **(Fig.1)

**

For the Wood Ceiling: Mark the location for the ceiling fan first, secure the mounting bracket to the building structure with four wood screws provided. (Fig.2)

NOTE: Hanger after the installation must be able to withstand the weight of 45 kgs or more.

INSTALL THE BLADE

  1.  Align the 2 holes from the balde to the fan motor.
    Secure blade with 3 blade screws with locked washer provided. Follow the same process for the remaining two blades.
    All blade sets are grouped together by weight.

  2. Tighten the screw in the specified position.

INSTALL THE DOWNROD, CANOPY AND PIN COVER

REMEMBER to turn off the power. Follow the steps below to hang your fan properly:

  1. Remove the lock pink and hitch pin from downrod
  2. Place downrod assembly into canopy and coupling cover, Carefully feed motor wires through the downrod assembly
  3. Loosen the two set screws in downrod coupling
  4. Insert downrod into downrod coupling. Install coupling lock pin through coupling and downrod. Insert hitch pin into cross pin until it snaps into place. Tighten set screws in coupling. Slide coupling cover over the downrod coupling.

| |
---|---|---
| |

CHANGE DOWNROD (OPT)
The Ceiling Fan comes with one 5 inches standard downrod which is preassembled and attached to the hanger ball, one longer 10 inches downrod is also included for higher ceilings.
If you need a different downrod length, please follow these steps:

  1. Loosen the hanger ball from downrod by removing set screw.
  2. Slide downrod ball off of downrod and remove pin
  3. Re-install pin into extended dowered, and slide downrod ball up to the top of the dowered
  4. Re-install set screw to secure ball to dowered

MAKE THE ELECTRIC CONNECTIONS

Make wiring connections from the remote receiver as shown right. the house and the motor to.

From House

From Fan

Note: the remote receiver must match the same code control

  • Light live-wire
  • Light neutral-wire
  • To motor wire
  • To motor wire
  • To motor wire

Note: the remote receiver must match the same code control.

Once wiring step has been completed, slide the wired remote receiver in between the mounting bracket and the top of the downrod ball for downrod fans.

USE OF REMOTE CONTROL

  1. ALL OFF: Turn off the lights and fans at the same time

  2. Fan Control Keys

  3. 3F/R: Changing fan run direction(15 sec)

  4. Timer: It will turn off the light and the fan when the time is over Turn on/off the light
    (This product does not have this feature.)

  5. Anti-theft lamp and natural wind
    (This product does not have this feature.)

Note: the remote control must match the same code receiver

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Sofucor User Manuals

Related Manuals